Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/12/2005 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection :* |
| 07/11/2005 |
PLUMBING - FINAL |
|
Partial Approval |
IVRS - Inspection :* REVISED CITY APPROVED PLAN ON SITE |
| 07/07/2005 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :* 1 PROVIDE REVISED CITY APPROVD PLANS &CALL IN ALL INSPECTIONS THAT HAVE NOT BEEN APPROVED. 2) SUPPORT PIPING AT WATER HEATER AND INSTALL WATER HEATER PIPING PER APPROVED PLAN. 3) EXPOSE ALL CLEANOUTS AT ALL SINKS. 4) PROVIDE PROOF WATER HEATER T & P DEVICE PROBE IS SUBMERGED INTO TANK. 5) SHAMPOO BOWL SINKS REQUIRE 6" MINIMUM FOR VACUUM BREAKER TO OVERFLOW RIM HEIGHT |