Permit: T04PL01956

Parcel: 10612016A

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T04PL01956

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
11/12/2004 PLUMBING - FINAL Approved IVRS - Inspection :*/1)CORRECTIONS MADE OK 2)OK FOR GAS 3)UCC LEFT AT METER SET
11/05/2004 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/YOU CANNOT USE PVC COLD WATER PIPE ON A T&P DRAIN. MUST BE CPVC, COPPER, GALVANIZED. PROVIDE 3 SCREWS IN EACH JOINT OF VENT ON WATER HEATER
11/03/2004 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/11 PSI TEST IS OK. FINISH HOOKING UP WATER HEATER. MUST HAVE DOUBLE WALL VENT PIPE THRU THE ROOF WITH MIN. 1" CLEARANCE FROM THE WOOD IN THE CEILING. CONNECT THE WATER PIPES & INSTALL A TEMPERATURE & PRESSURE RELIEF VALVE DRAINED TO THE OUTSIDE. NEED TO SEE GAS APPLIANCES INSIDE HOME. BE SURE ALL GAS SHUT OFF VALVES ARE AGA OR CSA APPROVED VALVES. RESCHEDULE AN INSPECTION AFTER CORRECTIONS HAVE BEEN MADE & SOMEONE WILL BE HOME.