09/03/2004 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*/10PSI AIR TEST ON NEW PIPING SCOTCH COAT APP. 8' UNDERGROUND TO EXISTING PIPING TO BUILDING OVERHEAD TO WATER HEATER & FURANCE OK
1)PROVIDE BONDING OF BUILDING GAS PIPING
2)SOAL PENETRATION AT WATER HEATER AREA
3)EXTEND VENT FROM WATER HEATER 3' ABOVE COOLER INTAKE AND SCREW CAP ON TO VENT PIPE
4)WATER HEATER T & P TO GRAVITY DRAIN TO DAYLIGHT