Inspection History Details
Inspection Status: Denied
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/08/2004 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ DBL WALL VENT FROM FURNACE AND WTR HTR IS TERMINATED INTO A SINGLE WALL TEE. CHANGE DBL WALL PIPE TO SINGLE WALL OR CHANGE TEE TO DBL WALL. DO NOT USE TAPE. PLUG UNUSED CONDENSATE OUTLET ON COIL. PROVIDE HOSE CLAMPS ON BOTH ENDS OF PLASTIC CONDENSATE HOSE. TIGHTEN ROMEX CONNECTORS ONTO POWER CORDS AND ATTACHMENT TO FURNACE COMPARTMENTS. SEAL AROUND REFER LINE PENETRATION. DO NOT USE A G.E. BREAKER IN A SIEMANS PANEL. YOU CAN ONLY USE SIEMANS BREAKERS. |