Case: T04FR00666

Parcel: 13401021C


Addresses:

125 S GOLLOB RD

Inspection Status: Violation

Inspection History: VIOL - MEANS OF EGRESS

Date Description Inspector Results Comments
11/22/2004 VIOL - MEANS OF EGRESS Violation TFC. 1008.1.8.4 Bolt locks.
Manually operated flush bolts or surface bolts are not permitted.
1. Remove all slide type locks from exits and doors
2. Remove or make imperative all dead bolt type locks from interior doors.
11/22/2004 VIOL - MEANS OF EGRESS Violation TFC. 1027.4 Furnishings and decorations.
Furnishings, decorations or other objects shall not be placed so as to obstruct exits,
access thereto, egress therefrom, or visibility thereof.

1. Remove desk from E. hallway or remove access from S. end of hallway and use as office.
11/22/2004 VIOL - MEANS OF EGRESS No Violation TFC. 1027.5 Emergency escape openings.
Required emergency escape openings shall be maintained in accordance with the code
in effect at the time of construction, and the following: Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars, grilles, grates or similar devices are allowed to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall
be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the escape and rescue opening.

1. At the time of construction emergency escape opening where not required.
But in the opinion of this code official the problem of emergency egress of the west hallway and bedrooms, the southeast bedroom and hallway, is greatly impaired by the construction. This condition may cause undue harm to residents if not brought up current code standards.
2. The current egress construction of the above location doesn't meet the min. requirements of the Behavioral Health Licensing. (R-20-405.B.7)

TFC. (IBC) 110.1 Use and occupancy.
No building or structure shall be used or occupied, and no change in the existing occupancy classification of a building or structure or portion thereof shall be made until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation
of the provisions of this code or of other ordinances of the jurisdiction.
1. New Certificate of Occupancy is required and will reflect the type use and equal to number of clients licensed by state.