Permit: T04EL02516

Parcel: 137070270


Addresses:

5151 S 12TH AV #02

Inspection Status: Denied

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
01/03/2005 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245* NOTES 1) INSTALL PERMANENT ADDRESS LABEL ON ELECT SERVICE. NO MARKING PEN. 2) INSTALL BUSHING WHERE WIRES PASS THRU DISCONNECT SWITCH INTO BLDG. 3) GROUNDING ELECTRODE CONDUCTOR CUT, NO WATER & GAS BOND. 4) RISER CONDUCTORS TO SHORT TO BE RE ATTACHED TO SERVICE DROP. 5) WIRING INSIDE AT SUB PANEL NOT WIRED PROPERLY. 6) RANGE HOOD NOT WIRED PROPERLY 7) INSTALL SMOKE DETECTORS IN BEDROOMS. 8) REPAIR BROKEN RECEPTACLES &LIGHT SWITCHES, LIGHT FIXTURES. COOLER MUST HAVE W/P BOX WITH COVER FOR PLUGS. WORK MUST BE DONE PER CODE , USE C-11 LICENSED CONTRACTOR.