Permit: T04EL02195

Parcel: 129020710


Addresses:

135 S STRATFORD DR


Inspection Status: Denied

Inspection History: ELECTRIC - FINAL

Permit Number - T04EL02195

Inspection Description - ELECTRIC - FINAL

Inspection Status - Denied

Date Description Inspector Results Comments
11/10/2004 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 139 S. STRATFORD DR: 1) LABEL BREAKER, BOND PANEL AND NEED A/C PERMIT
2) LABEL INTERIOR PANEL
3) NEED NEW FEEDER TO INTERIOR PANEL
4) PROPERLY GROUND ALL DEVICES
-----------------------------------------------------------------------------------------
145 S. STRATFORD DR: 1) NEED A/C PERMIT
2) LABEL PANEL BOARD
3) NEED NEW FEEDER TO PANEL BOARD
4) INPROPER CLEARANCE AT SUB PANEL
-----------------------------------------------------------------------------------------135 S. STRATFORD DR: 1) NEED SERVICE UPGRADE. SERVICE IS DAMAGED AND NOT SERVICEABLE. CLEANOUT IN FRONT OF SERVICE VIOLATES 110.26. OBTAIN UPGRADE PERMIT AND A/C PERMIT
2) PLEASE INDICATE OTHER SERVICES PER NEC 230.2 (E)
3) LABEL INTERIOR PANEL BOARDS WITH A PERMANENT TAG
4) WILL NEED A NEW FEEDER TO INTERIOR TO ACCOMADATE REPLACED PANEL BOARD AND EQUIPMENT GROUNDS FOR NEW ? BRANCH CIRCUITS
5) CHECK ALL DEVICES FOR PROPER GROUNDING
11/05/2004 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) METER 145 HAS 3 SERVICE DISCONNECTS, ONE OF WHICH IS NOT OPERATING PROPERLY-WILL NEED REPAIR/REPLACE (MAKE AND BREAK MECHANISM). THE WATER BOND CLAMP IS BROKEN
2) SERVICE 135 CANNOT LOCATE AND OR NOT LABELED
3) MORE THAN 2 AREAS OF SERVICE DROP. MUST LABEL AS PER NEC 230.2 (E)
4) NOTE: DIFICIENCIES NOTED ARE NOT COMPLETE AT THIS TIME
11/04/2004 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) NO COMPLIANCE WITH LAST INSPECTION
2) ADDRESS LABEL ON SERVICE MUST BE SCREWED OR RIVITED TO COVER
3) NO MARKING PEN, NO STICK ON NUMBERS
4) CHECK WITH PIMA COUNTY ADDRESSING 201 N. STONE
5) SAME RESULTS APPLY FOR 135 AND 139 S. STRAFORD DR.
11/01/2004 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*/ 1) HAVE TEP REMOVE LOCK ON SERVICE PANEL FOR INSPECTOR, SEE WRITE UP FOR #145
11/01/2004 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) PLEASE CONTACT TEP AND VERIFY METER NUMBERS WITH ADDRESSES. ADDRESS ON PERMIT MUST REFLECT BLDG ADDRESS, INSTALL PERMANENT ADDRESS LABELS ON CORRECT SERVICE 2) PERMIT CARD MUST BE POSTED ON BLDG'S