Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/07/2005 | INSP - INITIAL CODE ENFORCMENT | Approved | VISITED SITE, WALKED PROPERTY TO ACCESS PROGESS ON VIOLATION ISSED BY DNR UINTS 19 A,B,C, HAVE BEEN PAINTED, NEW WINDOW INSTALED (SAME FOR SAME) UINT 19 A HAZARDOUS PORCH STRUCTURE HAS BEEN REMOVED OVER HANG AT EASTSIDE HAS BEEN REPAIRED, PAINTED. NEW ELECTRICAL UP-GRADE FOR 19 A, B, & C HAS BEEN COMPLETED UNIT 19C IS CURRENTLY VACANT & SECURED AT THIS TIME. UNIT 17- EXTERIOR SURFACE HAS BEEN REPAIRED & PAINTED NEW WINDOWS INSTALLED (SAME AS SAME) NEW HOT WATER HEATER ENCLOSURE & PLUMBING HAS BEEN CORRECTED FOR HOT WATER HEATER. VENT STILL LACKING ON EAST SIDE OF UNIT. UNIT 15 C IS CURRENTLY BEING REHAB, NEW HOT WATER HEATER INSTALLED W/ ENCLOSURE, WASH BASIN IN VIOLATION HAS BEEN REMOVED. NEW WINDOWS INSTALLED (SAME FOR SAME) UNIT 19 B & C DETERIORATED 7 DELAPIDATED PORCH STRUCTURE HAS BEEN REMOVED. MAJORITY OF TERMITE INFESTED WOOD TRIM HAS BEEN REMOVED & REPLACED WITH NEW WOOD TRIM. OWNER MAKING GOOD PROGRESS ABATEMENT IME WILL BE EXTENDED 45 DAYS. PICTURES WERE TAKEN. |
|
| 12/02/2004 | INSP - INITIAL CODE ENFORCMENT | Approved | 19 W. LINCOLN ST - APT A ELECTRICAL: (1) HAZARDOUS ELECTRICAL, SEVERAL ELECTRICAL CONDUCTORS HAVE BENN STRUNG OUT IN PORCH AREA & CONTAIN ILLEGAL SPLICES. EXTERIOR RECEPTACLE HAS NO POWER & LACKING WEATHER PROTECTION. (2) 220 RECEPTACLE BY COOLER STAND IS DEAD & WILL BE REQUIRED TO REMOVE CIRCUIT. (3) ILLEGAL SPLICED CORDS FOR WALL FURNACE & AC WALL UNIT. (4) STRUCTURE HAS SEVERAL RECEPTACLES. (5) BATHROOM LIGHT FIXTURE HAS NON GROUNDED RECEPTACLE. (6) RECEPTACLE IN LAUNDRY ROOM IS DEAD & WILL REQUIRE REMOVAL FOR AC UNIT. (7) BROKEN LIGHT SWITCH COVER PLATE IN LAUNDRY. PLUMBING: (1) ADDITION OF GAS PIPINE, CHECK FOR PERMITS. (2) TOILET TANK FLAPPER LEAKING & LAVE SINK FAUCET LEAKING. (3) WASHING MACHINE DRAINING INTO VENT PIPE - NO P-TRAP. STRUCTURAL 1. HAZARDOUS PORCH STRUCTURE, STRUCTURE HAS BEEN BUILT WITHOUT PROPER ATTACHING HARDWARE AND USE OF 2 X 4 SPANNING OVER 4 FEET, ALL BOARDS ARE TOE NAILED. 4' X 4' POST HAVE BEEN NOTCHED MORE THAN A 3RD. 2. EAST SIDE OVERHANG HAS 3 FEET BY 2 FEET SECTION OF DRYWALL MISSING APPREARS SECTION HAS FALLEN OFF. HEATING 1. FURNACE IN LAUNDRYROOM APPEARS TO BE ORIGINAL AND NO LONGER IN USE, APPEARS ROOM WAS SEPERATED AND CLOSET WAS BOOTED IN. COOLER COOLER STAND IS NOT MADE OF APPROVED MATERIALS AND HAS NOT BEEN MAINTAINED. FRAME WORK IS 2 X 4 LUMBER AND IS LACKING PAINT. WEATHERPROOFING 1. BROKEN WINDOW AT WESTSIDE AND EASTSIDE (2). 2. WOOD FACSIA LACKING WEATHER PROTECTION PAIN COVERING AND BOARDS ARE IN A DETERIORATED STATE, CRACKED AND SPLITTING. INTERIOR FEATURES 1. FLOORING IN BEDROOM IS CRACKED AND BROKEN, SEVERAL PIECES ARE IN A DTERIORATED STATE. 2. BATHROOM WALL HAS SIGNS OF DETERIORATION HAS BEGUN TO CRUMBLE. 3. LAUNDRY ROOM CEILING HAS WATER DAMAGE. ACCESS CONTROL 1. WINDOWS ARE PAINTED SHUT AND SEVERAL WINDOW CRANKS MECHANISMS ARE NOT WORKING CORRECTLY. FIRE SAFETY 1. NO WORKING SMOKE DETECTORS. UNIT C STRUCTURAL 1. NORTH WINDOW HAS BEEN ALTERED SMALLER WINDOW HAS BEEN INSTALLED. EXTERIOR SURFACES 1. EXTERIOR SURFACE LACKING PAINT PROTECTION, SURFACE ARE CHIPPING OFF AND PEELING EXPOSED SURFACE. POSSIBLE ZONING VIOLATION -WEST PROPERTY IS WITHIN 3 FEET OF PROPERTY LINE. PLUMBING 1. NEWER COPPER LINES HAVE BEEN ADDED AND IS LACKING WEATHER PROTECTION AND NEED TO BE SECURED TO WALL. ELECTRICAL SYSTEMS 1. MAIN SERVICE IN A DETERIORATED AND DILAPIDATED STATE/OLDER TYPE 60 AMP SERVICE IS RUSTED AND LACKS WEATHER PROTECTION. 2. INTERIOR RECEPTACLE COVER PLATE IS BROKEN. 3. UNDERGROUNDED BATHROOM LIGHT FIXTURE 4. 3 PRONG RECEPTACLE INSTALLED IN 2 WIRE SYSTEM WEATHER PROTECTION 1. STORAGE SHED LACKING WEATHER PROTECTIVE PAINT COATING. 2. ENTRY DOOR LACKING WEATHER PROTECTION (WATHER STRIPPING). HEATING 1. WALL FURNACE LACKING APPROVED GAS VALVE SHUT OFF. |
|
| 12/02/2004 | INSP - INITIAL CODE ENFORCMENT | Approved | 17 W LINCOLN ST PLUMBING EXTERIOR PLUMBING 1. EXTERIOR SEWER VENT LACKING VENT TUBE OPENED FITTING AT WALL. 2. ALTERATION DONE TO EXTERIOR PLUMBING FOR ABS PIPING 3. TPR DRAIN VALVE LACKING DRAIN PIPE AND WEATHER PROTECTION. 4. LARGE AMOUNT OF COMBUSTABLE VEGETATION CHECK FOR PERMITS. 5. GAS PIPING HAS BEEN MODIFIED FOR GAS STOVE. EXTERIOR FEATURES 1. WOOD FASCIA IS IN A DETERIORATED SHAPE, WOOD IS CRACKING AND NEEDS WEATHER PROTECTIVE COATING AS WELL AS WINDOW FRAMES. 2. FRONT DOOR - EAST SIDE LACKS DOOR CASING ON TOP. WEATHER PROTECTION 1. BOTH ENTRY DOORS LACKING WEATHER STRIPPING. ELECTRICAL SYSTEM NOTE 2 WIRE SYSTEM 1. EXISTING PANEL HAS BEEN ALTERED, ADDITION OF CIRCUITS AND USE OF PLUMBING FIXTURE FOR CONDUIT. 2. PANEL LACKING DEAD PLATE COVER AND IS ABOVE 7'. 3. ELECTRICAL CONDUCTOR NOT IN CONDUIT FOR CEILING LIGHT FIXTURES IN LIVINGROOM AND KITCHEN. 4. 3 PRONG RECEPTACLES INSTALLED THROUGHOUT UNIT AND SOME SHOW REVERSED POLARITY. 5. BATHROOM LIGHT FIXTURES HAVE NON GROUNDED. FLOORING - INTERIOR FEATURES 1. LAUNDRY ROOM FLOORING IN A DETERIORATED STATED, FLOORING HAS CHIPPED OFF AND CRACKED. |
|
| 12/02/2004 | INSP - INITIAL CODE ENFORCMENT | Approved | 15 W LINCOLN ST APT C WEATHER PROTECTION 1. ENTRY DOOR LACKING WEATHER STRIPPING 2. 1 WINDOW OPENING HAS BEEN BOARDED HEATING 1. WALL FURNACE LACKING SERVICING PLUMBING 1. SHOWER HOSE IS NOT WATER RESISTANT AND LACKING DRAIN COVER. WEATHER PROTECTION 1. FRONT DOOR LACKING WEATHER STRIPPING. HEATING AND COOLING 1. NEEDS SERVICING 2. COOLER VENT INSECT CONTROL HAS DETATCHED FROM FRAME. 1. TERMITE DAMAGE WINDOW SILL IN LIVING ROOM ACCESS CONTROL 1. DOUBLE KEYED DEAD BOLT IN BACK DOOR AND FRONT DOOR 2. REAR ENTRY DOOR HAS BEEN INSTALLED WITH HINGES TO THE OUTSIDE ELECTRICAL 1. SYSTEM IS 2 WIRE 3 PRONG RECEPTACLE HAVE BEEN INSTALLED. 2. RECEPTACLE LACKING COVERPLATE. 3. SERVICE PANEL ABOVE WASH BASIN PLUMBING 1. GAS PIPING ABOVE FINISHED FLOOR APPROXIMATELY 4" AND IS CAPPED INTERIOR FEATURES 1. CLOSET WALL AND DOOR IN A DILAPIDATED CONDITION, BOTTOM OF WALL AND DOOR SKINS HAVE SEPERATED AND HOLES. 2. HOT WATER HEATER INSTALLED W/O/P LACKING TPR DRAIN AND FLUE PIPING NOT AN APPROVED BASE. ELECTRICAL 4. EXTERIOR RECEPTACLE LACKING WEATHER PROTECTION. APPEARS NEW SERVICE DISCONNECTS ARE OVER FUSED AND WILL REQUIRE ACCESSMENT BY ELECTRICAL CONTRACTOR WITH C-11 LICENSED. |
|
| 11/29/2004 | INSP - INITIAL CODE ENFORCMENT | Approved | UNIT B ELECTRICAL: (1) STUDIO - RECEPTACLE LACKING COVER PLATE & RECESSED IN WALL, OUTLET NOT PROPERLY SECURED. (2) BATHROOM - ADDITION OF 3 WIRE CIRCUIT LACKING GFI PROTECTION, RECEPTACLE - SHOWS REVERSED HOT NEUTRAL ON SAME CIRCUIT. (3) RECEPTACLE IN KITCHEN SHOWS REVERSED HOT NEUTRAL. (4) NO GFIC IN KITCHEN. (5) RECEPTACLE IN KITCHEN BY WINDOW IS NOT LIVE. WINDOW - WEATHER PROOFING: (1) SEVERAL WINDOWS ARE BROKEN TROUGHOUT STRUCTURE. (2) ENTRY DOOR LACKING WEATHER STRIPPING, TOP OF DOOR HAS 3/4 INCH GAP. HEATING & COOLER: (1) SUPPLY LINE TO MANIFOLD PIPING HAS BROKEN AWAY FROM MANIFOLD HEATING SYSTEM IN A HAZARDOUS CONDITION. D.N.R. ON SITE INSPECTOR SHUT DOWN SYSTEM & ADVISED TENANT NOT TO USE. HEATING SYSTEM WILL REQUIRE LICENCED HEATING CONTRACTOR TO ACCESS. (2) COOLER STAND IS NOT MADE OF APPROVED MATERIAL. PLUMBING: (1) SHOWER STALL LACKING DRAIN COVER & SHOWER HEAD. (2) TOILET FLAPPER LEAKING. (3) ACCESS PANEL MISSING IN CLOSET FOR SHOWER. (4) W/O/P MODIFICATION HAVE BEEN DONE TO EXISTING WATER SUPPLY LINE FOR SHOWER. (5) KITCHEN DRAIN LACKING. (6) WASTE BASKET HAS NOT BEEN INSTALLED UP PROPERLY, HAS BEEN TAPPED TO STOP LEAKS W/ DUCT TAPE. ACCESS CONTROL: (1) LATCHING MECHANISM NOT WORKING PROPERLY ON 2 WINDOWS 1 IN KITCHEN & OTHER IN LIVING ROOM. FIRE SAFETY: (1) LACKING WORKING SMOKE DETECTORS. W/O/P PLUMBING - ELECTRICAL: (1) HOT WATER TANK LACKING CONNECTION TO T.R.P. DRAIN. (2) LACKING APPROVED GAS VALVE. (3) MAY HAVE BEEN INSTALLED WITHOUT PERMIT. (4) SERVICE ELECTRICAL SYSTEM HAS MAJOR MODIFICATION DONE 1-15 AMP CIRCUIT RUNS HOLE APT. 2-ELECTRICAL DISCONNECTS ARE IN A DETERIORATED STATE, WIRES ARE FRAYED & INTERIOR OF DISCONNECT IS RUSTED, LACKING WEATHER PROTECTION. ELECTRICAL GUTTER NOT RAIN TILE. (5) MODIFICATIONS HAVE BEEN DONE FOR DRAINING OF WASHER. (6) 3-PRONG RECEPTACLE FOR COOLER LACKING WEATHER PROOF COVER & LACKING PROPER GROUND. |
|
| 11/29/2004 | INSP - INITIAL CODE ENFORCMENT | Approved | VISITED SITE ATTEMPTED TO MAKE CONTACT WITH COMPLAINTANT NO ONE HOME. SPOKE WITH NEIGHBOR MADE CONTACT WITH COMPLAINTANT'S SISTER, IDENTIFIED OURSELVES AND EXPLAINED TO TENANT WHY WE WERE ON SITE. SISTER ALLOWED INSPECTION OF HER UNIT 19B ACCORDING TO HER THERE ARE 7 UNITS. INSPECTOR HAD SEVERAL TENANT'S APPROACH US FOR INSPECTION. INFORMED TENANTS DNR WILL CONTACT OWNER AND SET UP INSEPCTION TIME FOR ALL OTHER APTS. LEFT MESSAGE FOR ORIGINAL TENANT TO MAKE CONTACT WITH DNR INSPECTOR SEVERAL MIN HOUSING ISSUES WERE FOUND AND ARE AS FOLLOWS: |