Case: T04DV00900
Case Details
Entered Date:
11/15/2004
Applicant:
HIGUERA JOAQUIN M & CONNIE L JT/RS 1/2 &
Description:
COMPLAINT RE: MIN HOUSING-INFESTED W/ ROACHES & MICE. ALL WINDOWS IN UNIT DO NOT SECURE PROPERLY. SMALL HOLE IN KITCHEN CEILING.
Outstanding Inspections
Case Number: T04DV00900
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 12
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| NPO - UNSECURED BUILD OR STRUC | None | Not Inspected | ||
| NPO(EL)-MAIN/PANEL/SUB/DISCONT | None | Not Inspected | ||
| VIOL(EL) - CIRCUITS | None | Not Inspected | ||
| VIOL(EL)-SUBPANELS/DISCONNECTS | None | Not Inspected | ||
| NPO(EL)-WIRING/SWITCH/OUTLT/FX | None | Not Inspected | ||
| NPO(PL)-PLUMBING SYSTEM & FX | None | Not Inspected | ||
| NPO(PL)-GAS SUPPLY/CONNECT | None | Not Inspected | ||
| VIOL(PL) - FIXTURES | None | Not Inspected | ||
| NPO(PL)-WATER HEATERS | None | Not Inspected | ||
| NPO(HC)-HEATING & VENTILATION | None | Not Inspected | ||
| VIOL(SA) - BATHS | None | Not Inspected | ||
| VIOL(SA) - KITCHEN | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T04DV00900
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 5
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/02/2004 | INSP - INITIAL CODE ENFORCMENT | HLOPEZ | Approved | 15 W LINCOLN ST APT C WEATHER PROTECTION 1. ENTRY DOOR LACKING WEATHER STRIPPING 2. 1 WINDOW OPENING HAS BEEN BOARDED HEATING 1. WALL FURNACE LACKING SERVICING PLUMBING 1. SHOWER HOSE IS NOT WATER RESISTANT AND LACKING DRAIN COVER. WEATHER PROTECTION 1. FRONT DOOR LACKING WEATHER STRIPPING. HEATING AND COOLING 1. NEEDS SERVICING 2. COOLER VENT INSECT CONTROL HAS DETATCHED FROM FRAME. 1. TERMITE DAMAGE WINDOW SILL IN LIVING ROOM ACCESS CONTROL 1. DOUBLE KEYED DEAD BOLT IN BACK DOOR AND FRONT DOOR 2. REAR ENTRY DOOR HAS BEEN INSTALLED WITH HINGES TO THE OUTSIDE ELECTRICAL 1. SYSTEM IS 2 WIRE 3 PRONG RECEPTACLE HAVE BEEN INSTALLED. 2. RECEPTACLE LACKING COVERPLATE. 3. SERVICE PANEL ABOVE WASH BASIN PLUMBING 1. GAS PIPING ABOVE FINISHED FLOOR APPROXIMATELY 4" AND IS CAPPED INTERIOR FEATURES 1. CLOSET WALL AND DOOR IN A DILAPIDATED CONDITION, BOTTOM OF WALL AND DOOR SKINS HAVE SEPERATED AND HOLES. 2. HOT WATER HEATER INSTALLED W/O/P LACKING TPR DRAIN AND FLUE PIPING NOT AN APPROVED BASE. ELECTRICAL 4. EXTERIOR RECEPTACLE LACKING WEATHER PROTECTION. APPEARS NEW SERVICE DISCONNECTS ARE OVER FUSED AND WILL REQUIRE ACCESSMENT BY ELECTRICAL CONTRACTOR WITH C-11 LICENSED. |
| 12/02/2004 | INSP - INITIAL CODE ENFORCMENT | HLOPEZ | Approved | 17 W LINCOLN ST PLUMBING EXTERIOR PLUMBING 1. EXTERIOR SEWER VENT LACKING VENT TUBE OPENED FITTING AT WALL. 2. ALTERATION DONE TO EXTERIOR PLUMBING FOR ABS PIPING 3. TPR DRAIN VALVE LACKING DRAIN PIPE AND WEATHER PROTECTION. 4. LARGE AMOUNT OF COMBUSTABLE VEGETATION CHECK FOR PERMITS. 5. GAS PIPING HAS BEEN MODIFIED FOR GAS STOVE. EXTERIOR FEATURES 1. WOOD FASCIA IS IN A DETERIORATED SHAPE, WOOD IS CRACKING AND NEEDS WEATHER PROTECTIVE COATING AS WELL AS WINDOW FRAMES. 2. FRONT DOOR - EAST SIDE LACKS DOOR CASING ON TOP. WEATHER PROTECTION 1. BOTH ENTRY DOORS LACKING WEATHER STRIPPING. ELECTRICAL SYSTEM NOTE 2 WIRE SYSTEM 1. EXISTING PANEL HAS BEEN ALTERED, ADDITION OF CIRCUITS AND USE OF PLUMBING FIXTURE FOR CONDUIT. 2. PANEL LACKING DEAD PLATE COVER AND IS ABOVE 7'. 3. ELECTRICAL CONDUCTOR NOT IN CONDUIT FOR CEILING LIGHT FIXTURES IN LIVINGROOM AND KITCHEN. 4. 3 PRONG RECEPTACLES INSTALLED THROUGHOUT UNIT AND SOME SHOW REVERSED POLARITY. 5. BATHROOM LIGHT FIXTURES HAVE NON GROUNDED. FLOORING - INTERIOR FEATURES 1. LAUNDRY ROOM FLOORING IN A DETERIORATED STATED, FLOORING HAS CHIPPED OFF AND CRACKED. |
| 12/02/2004 | INSP - INITIAL CODE ENFORCMENT | HLOPEZ | Approved | 19 W. LINCOLN ST - APT A ELECTRICAL: (1) HAZARDOUS ELECTRICAL, SEVERAL ELECTRICAL CONDUCTORS HAVE BENN STRUNG OUT IN PORCH AREA & CONTAIN ILLEGAL SPLICES. EXTERIOR RECEPTACLE HAS NO POWER & LACKING WEATHER PROTECTION. (2) 220 RECEPTACLE BY COOLER STAND IS DEAD & WILL BE REQUIRED TO REMOVE CIRCUIT. (3) ILLEGAL SPLICED CORDS FOR WALL FURNACE & AC WALL UNIT. (4) STRUCTURE HAS SEVERAL RECEPTACLES. (5) BATHROOM LIGHT FIXTURE HAS NON GROUNDED RECEPTACLE. (6) RECEPTACLE IN LAUNDRY ROOM IS DEAD & WILL REQUIRE REMOVAL FOR AC UNIT. (7) BROKEN LIGHT SWITCH COVER PLATE IN LAUNDRY. PLUMBING: (1) ADDITION OF GAS PIPINE, CHECK FOR PERMITS. (2) TOILET TANK FLAPPER LEAKING & LAVE SINK FAUCET LEAKING. (3) WASHING MACHINE DRAINING INTO VENT PIPE - NO P-TRAP. STRUCTURAL 1. HAZARDOUS PORCH STRUCTURE, STRUCTURE HAS BEEN BUILT WITHOUT PROPER ATTACHING HARDWARE AND USE OF 2 X 4 SPANNING OVER 4 FEET, ALL BOARDS ARE TOE NAILED. 4' X 4' POST HAVE BEEN NOTCHED MORE THAN A 3RD. 2. EAST SIDE OVERHANG HAS 3 FEET BY 2 FEET SECTION OF DRYWALL MISSING APPREARS SECTION HAS FALLEN OFF. HEATING 1. FURNACE IN LAUNDRYROOM APPEARS TO BE ORIGINAL AND NO LONGER IN USE, APPEARS ROOM WAS SEPERATED AND CLOSET WAS BOOTED IN. COOLER COOLER STAND IS NOT MADE OF APPROVED MATERIALS AND HAS NOT BEEN MAINTAINED. FRAME WORK IS 2 X 4 LUMBER AND IS LACKING PAINT. WEATHERPROOFING 1. BROKEN WINDOW AT WESTSIDE AND EASTSIDE (2). 2. WOOD FACSIA LACKING WEATHER PROTECTION PAIN COVERING AND BOARDS ARE IN A DETERIORATED STATE, CRACKED AND SPLITTING. INTERIOR FEATURES 1. FLOORING IN BEDROOM IS CRACKED AND BROKEN, SEVERAL PIECES ARE IN A DTERIORATED STATE. 2. BATHROOM WALL HAS SIGNS OF DETERIORATION HAS BEGUN TO CRUMBLE. 3. LAUNDRY ROOM CEILING HAS WATER DAMAGE. ACCESS CONTROL 1. WINDOWS ARE PAINTED SHUT AND SEVERAL WINDOW CRANKS MECHANISMS ARE NOT WORKING CORRECTLY. FIRE SAFETY 1. NO WORKING SMOKE DETECTORS. UNIT C STRUCTURAL 1. NORTH WINDOW HAS BEEN ALTERED SMALLER WINDOW HAS BEEN INSTALLED. EXTERIOR SURFACES 1. EXTERIOR SURFACE LACKING PAINT PROTECTION, SURFACE ARE CHIPPING OFF AND PEELING EXPOSED SURFACE. POSSIBLE ZONING VIOLATION -WEST PROPERTY IS WITHIN 3 FEET OF PROPERTY LINE. PLUMBING 1. NEWER COPPER LINES HAVE BEEN ADDED AND IS LACKING WEATHER PROTECTION AND NEED TO BE SECURED TO WALL. ELECTRICAL SYSTEMS 1. MAIN SERVICE IN A DETERIORATED AND DILAPIDATED STATE/OLDER TYPE 60 AMP SERVICE IS RUSTED AND LACKS WEATHER PROTECTION. 2. INTERIOR RECEPTACLE COVER PLATE IS BROKEN. 3. UNDERGROUNDED BATHROOM LIGHT FIXTURE 4. 3 PRONG RECEPTACLE INSTALLED IN 2 WIRE SYSTEM WEATHER PROTECTION 1. STORAGE SHED LACKING WEATHER PROTECTIVE PAINT COATING. 2. ENTRY DOOR LACKING WEATHER PROTECTION (WATHER STRIPPING). HEATING 1. WALL FURNACE LACKING APPROVED GAS VALVE SHUT OFF. |
| 11/18/2005 | EMERGENCY CALL OUT | HLOPEZ | Approved | CHECKED PROGRESS IN PERMITS PLUS PROGRAM. COMBO PERMITS #T05CM01808 FOR PLUMBING AND ELECTRICAL HAVE BEEN FINALED FOR ADDRESS 15 W LINCOLN ST. COMBO PERMIT FOR ADDRESS 17 W LINCOLN ST #T05CM01809 HAS ALSO BEEN FINALED. REMAINING PERMIT FOR ADDRESS 19 W LINCOLN ST HAS BEEN INSPECTED AND REQUIRES CORRECTION FOR ELECTRICAL SYSTEM #T05CM01810. CONTACTED OWNER, OWNER NOT HOME. SPOKE WITH DAUGHTER, LEFT MESSAGE REQUESTING STATUS OF REMAINING VIOLATIONS UNABATED. LEFT CALL NUMBER AND OFFICE NUMBER FOR CONTACT AND REMINDED DAUGHTER PERMITS EXPIRES 12-11-05. OWNERS HAVE MADE GOOD PROGRESS, WILL GRANT 1 MORE EXTENSION FOR 30 DAYS. SCHEDULE ON SITE INSPECTION FOR COMPLAINCE FOR 12-30-05 |
| 05/08/2006 | INSP - FOLLOW UP CODE ENFORCE | HLOPEZ | Approved | VISITED SITE ON FW/UP INSPECTION FOR COMPLIANCE. PRESENT AT SITE WERE OWNERS & DNR INSPECTORS H. LOPEZ & J. ORTA. FINDINGS ARE AS FOLLOWS FOR REMAINING UNABATED VIOLATIONS: 6) TC 16-11 (C) ELECTRICAL SYSTEM 1 & 2 TC16-4 PERMIT REQUIRED. VIOLATION ABATED - ILLEGALLY GROUNDED RECEPTACLES WERE CORRECTED. GFIC RECEPTACLE INSTALLED IN FIRST POSITION IN CIRCUIT & PROTECTS ALL OTHER DOWN THE LINE. RECEPTACLES DOWN THE LINE ARE MARKED NO EQUIPMENT GROUNDS. PICTURES WERE TAKEN. OWNERS HAVE COMPLIED & ABATED ALL ISSUES PER CODE REQUIREMENTS. CLOSE CASE & MARK COMPLIANCE. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T04DV00900
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
| Date | Name |
| 07/13/2005 | CONTACTED BY PHONE |
| 04/12/2005 | NOTICE OF VIOLATION ISSUED |
| 04/12/2005 | COURT ORDERED ABATEMENT |
| 05/09/2006 | VIOLATION CLOSED |
| 09/14/2005 | SPOKE WITH.. |