Inspection History Details
Inspection Status: Compliance
Inspection History: INSP - FOLLOW UP CODE ENFORCE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/09/2004 | INSP - FOLLOW UP CODE ENFORCE | Compliance | LAST REMAING VIOLATION REMOVED DID FW/UP INSPECTION AFTER RECEVING CALL FROM OWNERS. PORCH STRUCTURE IN VIOLATION HAS BEEN REMOVED & VERIFIED. OWNERS ARE IN COMPLANCE |
|
| 10/12/2004 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | VISITED SITE ON 2ND FOLLOW UP INSPECTION. MET WITH OWNER JERRY AND MANAGER MR BATES. WENT OVER UNABATED ITEMS. APT 1 ELECTRICAL - UNGROUNDED RECEPTACLE WAS REMOVED AND NEW LIGHT FIXTURE INSTALLED WITH OUT RECEPTACLE. ABATED 9/27/04. APT 2 PLUMBING - NON ABSORBENT MATERIAL REMOVED AND REPLACED WITH NEW CERAMIC TILE. ABATED 9/27/04. ELECTRICAL 1. LIGHT FIXTURE W/RECEPTACLE HAS BEEN REMOVED, NEW LIGHT FIXTURE WAS INSTALLED. 2. 3 PRONG RECEPTACLE REMOVED AND REPLACED W/ 2 PRONG RECEPTACLE. ABATED 9/27/04. APT 5 MECHANICAL - PERFORATED 23 GAUGE SCREEN HAS BEEN INSTALLED AS PROTECTIVE COVER. ABATED 9/27/04. PLUMBING - NEW CERAMIC TILE INSTALLED FOR SHOWER STALL. ABATED 9/27/04. ELECTRICAL - RECEPTACLE W/LIGHT FIXTURE WAS REMOVED AND NEW LIGHT FIXTURE WITHOUT RECEPTACLE INSTALLED. ABATED 9/27/04. APT 6 KITCHEN - ELECTRICAL - SINK AREA NON GROUNDED RECEPTACLE IN KITCHEN AREA WERE REMOVED AND NEW 2 PRONG RECEPTACLES INSTALLED. ABATED 9/27/04. INTERIOR FEATURES BATHROOM WALL RESTORED AND PAINTED, NEW TILE INSTALLED IN SHOWER AREA - ABATED 9/27/04. WEATHER PROTECTION - BROKEN WINDOW GLAZE REPLACED - ABATED 9/27/04. FLOORING - BROKEN FLOOR TILES REPLACED AND HOLES AROUND PLUMBING HAVE BEEN SEALED. ABATED 10/12/04. APT 7 - ELECTRICAL - LIGHT FIXTURE WITH NON GROUNDED RECEPTICLE HAS BEEN REMOVED AND REPLACED WITH NEW LIGHT FIXTURE WITHOUT RECEPTICLE ABATED 9/27/04. PLUMBING - SHOWER STALL CEILING AND SHOWER WALLS REPAIRED, REPAINTED AND NEW CERAMIC TILE INSTALLED. ABATED 9/27/04. APT 9 - RENOVATION COMPLETED, NEW 2 PRONG RECEPTACLES INSTALLED AND NEW CERAMIC TILE INSTALLED. ABATED 10/12/04. APT 8 - ELECTRICAL - NON GROUNDED RECEPTACLE LIGHT FIXTURE WITH NO RECEPTACLE. ABATED 9/27/04. PLUMBING - DETERIORATED AND NON ABSORBENT MATERIALS WERE REMOVED AND REPLACED WITH NEW CERAMIC TILE. HOLES IN WALL WERE PATCHED AND PAINTED. ABATED 9/27/04. APT 10 - ELECTRICAL 1. NEW COVER PLATE INSTALLED. 2. NON - GROUNDED RECEPTACLE REMOVED AND REPLACED WITH NEW LIGHT FIXTURE WITHOUT RECEPTACLE. ABATED 09/27/04. INTERIOR SURFACES - DETERIORATED WALL REPAIRED, NEW CERAMIC TILE INSTALLED ON WALL. ABATED 09/27/04. PLUMBING - LOOSE TILES RESECURED, NEW HANDLES INSTALLED IN SHOWER STALL AND TOILET BOWL RESECURED TO CLOSET FLANGE ABATED 9/27/04. WEATHER PROTECTION BROKEN WINDOW GLAZING WAS REPLACED ABATED 9/27/04. HALLWAY - BROKEN WINDOW GLAZING REPLACED AND NAILS REMOVED FROM CASING. ABATED 9/27/04. |