Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

09/03/2004

Applicant:

PASCOE CLIFFORD & KATHERINE JT/RS

Description:

COMPLAINT:MIN HOUSING-ROACHES, LEAKS IN SINKS (BATHROOM). TOILET IS NOT SECURED.

Completed Inspections

Case Status: COMPLIAN
Case Number: T04DV00730
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
09/09/2004 INSP - INITIAL CODE ENFORCMENT HLOPEZ Approved VISITED SITE ON INITIAL INSPECTION, PRESENT WERE OWNERS TERRY & DEAN, MANAGER (MR. BATES) AND DNR INSPECTOR. TEN APT COMPLEX HAS BEEN TURNED INTO HALF-WAY HOUSE FOR DRUG OFFENDERS. WALKED ALL UNITS WITH OWNERS & MANAGER, SEVERAL MIN HOUSING ISSUES WERE FOUND THROUGHOUT INTERIOR & EXTERIOR STRUCTURES. MIN HOUSING ISSUES ARE AS FOLLOWS. PICTURES WERE TAKEN. APT. #1 (ELECTRICAL) UNGROUNDED RECEPTACLE AT BATHROOM LIGHT FIXTURE. APT. #2 (PLUMBING) SHOWER MADE OF NON-ABSORBENT MATERIAL, MATERIAL IS CHARLXED & SHOWER HAS BEGUN TO DETERIORATE. (ELECTRICAL) REMOVE AND OR REPLACE ELECTRICAL RECEPTACLE AT BATHROOM. LIGHT FIXTURE RECEPTACLE IN CLOSET HAS NO GROUND. APT. #5 (MECH.) WALL FURNACE LACK PROTECTIVE COVER FOR FRONT. (PLUMBING) SHOWER FLOORING DETERIORATED BROKEN FLOOR TILE IN STALL. (ELECTRICAL) REMOVE AND OR REPAIR ELECTRICAL RECEPTACLE IN BATHROOM LIGHT FIXTURE. APT. #7 (ELECTRICAL) REMOVE AND OR REPAIR ELECTRICAL RECEPTACLE FOR BATHROOM LIGHT FIXTURE. (PLUMBING) SHOWER STALL IN A DETERIORATED STATE, PAINT CHIPPING AND PEALING AND WEST SHOWER WALL MATERIAL IS BROKEN, SECTION MISSING APPROX 18"X12" APT. #6-KITCHEN (ELECTRICAL) SINK AREA - NON GROUNDED RECEPTACLE. (INTERIOR FEATURES) BATHROOM WALL HAS DETERIORATED INTO A DELAPATATED STATE. (WEATHER PROTECTION) BROKEN WINDOW. (FLOORING) SINK AREA SEVERAL BROKEN TILES. APT. #9 UNDER RENOVATION AT THIS TIME. APT. #8 (ELECTRICAL) REMOVE & OR REPLACE ELECTRICAL RECEPTACLE AT BATHROOM LIGHT FIXTURE. (PLUMBING) SHOWER STALL IN A DETERIORATED STATE, NON ABSORBENT MATERIALS, HOLES IN WALL BY TOILETS. APT. #11 - OFFICE (PLUMBING) SHOWER STALL FLOOR TILE LACKING GROUTING & CEILING CRACKED, PAINT IS PEELING. (ELECTRICAL) REMOVE AND OR REPLACE ELECTRICAL RECEPTACLE IN BATHROOM LIGHT FIXTURES, SPRONG RECEPTACLE ON SOUTH WALL. (WEATHER PROTECTION) BROKEN WINDOW ON WESTSIDE (NOTE) OFFICE UNDER RENOVATION. (HALL WAY) BROKEN WINDOW & NAILED SHUT. APT. #10 (ELECTRICAL) RECEPTACLE LACKING COVER PLATE ON SOUTH WALL. REMOVE & OR REPLACE ELECTRICAL RECEPTALCE IN BATHROOM BY FIXTURE. (INTERIOR SURFACES) BATHROOM WALLS IN A DETERIORATED STATE. (PLUMBING) SHOWER STALL IN A DETERIORATED STATE, LOOSE TILES IN STALL, HANDLES MISSING, TOILET LOOSE. (WEATHER PROTECTION) BROKEN WINDOW ON WESTSIDE. APT. #3 (ELECTRICAL) REMOVE & OR REPLACE ELECTRICAL RECEPTACLE IN BATHROOM LIGHT FIXTURE. ELECTRICAL COVER PLATE MISSING. (INTERIOR SURFACES) CLOSET CEILING HAS WATER DAMAGE, REPAIR & TEXTURE PAINT. CEILING IN BEDROOM, PATCHED AREA HAS NOT BEEN COMPLETE LACKING TEXTURE & PAINT. (LAUNDRY ROOM- PLUMBING) W/O/P ADDITION OF 100GAL HOT WATER NOT INSTALLED UNDER PERMIT. ADDITION OF WATER LINES P.V.C. & LACKING DRAIN. (ELECTRICAL) EXPOSED ELECTRICAL CONDUCTORS ADDITION OF 220 CIRCUIT & EXPOSED ELECTRICAL CONDUCTOR COMING FROM BEDROOM WINDOW. CEILING LIGHT FIXTURE EXPOSED ROMEX. (STRUCTURAL) ROOF OF LAUNDRY ROOM IS IN A DETERIORATED STATE, SECTION HAS HAD WATER DAMAGE 3/4 PLYWOOD COMING APART. (PORCH AREA) HAS NOT BEEN DONE UNDER PERMIT, EVIDENCED BY USE OF 2X4 SPANING OVER EIGHT FT 2 SECTION ARE IN DETERIORATED STATE, EVIDENCED BY 2X4 USED AS FASCIA BOARD HAS SPLIT & SAGGING PARTICALE BOARD COMING APART.
12/09/2004 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Approved LAST REMAING VIOLATION REMOVED DID FW/UP INSPECTION AFTER RECEVING CALL FROM OWNERS. PORCH STRUCTURE IN VIOLATION HAS BEEN REMOVED & VERIFIED. OWNERS ARE IN COMPLANCE

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T04DV00730
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
11/29/2004 CONTACTED BY PHONE
12/23/2004 COURT ORDERED ABATEMENT
12/23/2004 VIOLATION CLOSED