Case: T04DV00155

Parcel: 11308291B


Addresses:

814 E HEDRICK DR

Inspection Status: Correction Required

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Date Description Inspector Results Comments
02/07/2008 INSP - FOLLOW UP CODE ENFORCE Correction Required 2/7/08, OLD CASE.
C-13 WHEN VISITED SITE, DUE TO LIVING IN A SHED, THIS WAS DEALTH WITH AND CORDS WERE REMOVED, STATED SON USED AS CLUBHOUSE.
PROPERTY IS 2 SEPERATE PARCELS, OTHER ISSUES ON DIFFERENT PARCEL.
MAIN HOUSE VACANT, NO ONE UTILIZING SHED.
THIS WAS ISSUE OF CASE T04DV00155.
INSPECTOR ORTA HAS NEW CASE OPENED FOR SEPERATE ISSUES ON DIFFERENT PARCEL INCLUDING J.M.V.'S GARAGE, VEG. ETC.
TALKED WITH SUPERVISIOR RICK S, CONCURRED TO CLOSE T04DV00155 AND REFER TO CASE # T07DV13297 INSP. ORTA CASE OPEN
03/28/2005 INSP - FOLLOW UP CODE ENFORCE Approved 3/28/05 RE-VISITED SITE, MET WITH OWNERS, SAID THEY REMEMBERED C-13 FROM FIRST INSP. SAID SOME CHANGES HAD BEEN MADE, AND THAT THEY HAD NOT HEARD FROM DNR FOR SOME TIME. INSP HURD TOLD THEM THAT WE WERE BACK OUT TO SEE IF ANY CORRECTIONS HAD BEEN MADE.
CHECKED THE ELECTRICAL SERVICE TO THE MAIN HOUSE, WHICH RAN OFF OF THE MAIN SERVICE TO THE PROPERTY WHICH WAS ACTUALLY LOCATED AT THE SHOP/GARAGE. OWNER MENTIONED THAT SERVICE AT HOUSE HAD BEEN CORRECTED BY AN ELECTRICIAN. IT DID APPEAR TO HAVE BEEN DONE CORRECTLY, NO APPARENT PROBLEMS.
CHECKED HOTWATER HEATER, NO CHANGES HAD BEEN MADE.WATER HEATER STILL MISSING DRAIN PIPE, COLD WATER SHUT OFF, AND FLUE PIPE NEEDS TO BE SEALED AT JOINTS.
ADDED ROOF OVER GARAGE STORAGE NEEDS TO BE REMOVED,IMPROPERLY BUILT, NOTHING CORRECT ABOUT IT. RAFTERS OVER SPAN AND NOT CONTINUOS. NO TIE DOWN CONNECTORS. RAFTERS LIE ON ACTUAL ROOF OF A STORAGE SHED.
ELECTRICAL PEDESTAL FOR SHOP PROBABLY WORK WITHOUT PERMITS, AND PEDESTAL NOT PROPERLY MOUNTED OR SECURED. WOOD PEDESTAL DETERIORATING.
MAIN ELECTRICAL SERVICE AT SHOP (METERED PANEL) HAS EXPOSED WIRING, KNOCK OUTS AND DEAD PLATES MISSING.
OBVIOUS TRASH,DEBRIS, AND JUNK MOTOR VEHICLES.
STORAGE SHED NOT BUILT CORRECTLY, STUDS IN BEARING WALLS OVER SPANNED, RAFTERS OVER SPANNED, AND CENTER BEARING 1 X 6 INADEQUATE.

WILL COMPLETE FURTHER RESEARCH/ NOV TO FOLLOW