Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

02/23/2004

Applicant:

HERRERA SYLVIA

Description:

COMPLAINT:MIN HOUSING-LOOKS LIKE BEING LIVED IN. PROPERTY IN SHAMBLES.

Outstanding Inspections

Case Number: T04DV00155
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 10
End Date Description Inspector Results Comments
VIOL(BL) - DETACHED STRUCTURES None Not Inspected
VIOL(BL) - LIVING AREAS None Not Inspected
VIOL(BL) - ROOF None Not Inspected
NPO(EL)-MAIN/PANEL/SUB/DISCONT None Not Inspected
VIOL(EL)-SUBPANELS/DISCONNECTS None Not Inspected
NPO(EL)-WIRING/SWITCH/OUTLT/FX None Not Inspected
NPO(PL)-WATER HEATERS None Not Inspected
VIOL(FS) - HAZARDOUS STORAGE None Not Inspected
03/15/2004 INSP - INITIAL CODE ENFORCMENT JHURD Correction Required 3/9/04, VISITED SITE, TOOK PICTURES, FOUND SEVERAL DIFFERENT LOTS ON PROPERTY, 816 SETS IN FRONT OF PROPERTY, 814, 812, 810 SETS TO REAR OF PROPERTY, LOT FOR 810 WAS IN QUESTION, IT HAS A SMALL DETACHED 9'X12' STRUCTURE ON IT, THIS AT ONE TIME APPEARS TO HAVE BEEN POSSIBLE RENTAL OR GUEST ROOM, DOES HAVE BAATH TOILET AND SINK WITH RUNNING WATER, HAD EXTENSION CORD GOING THROUGH WINDOW FOR ELECTRIC POWER, ON INTERIOR WAS A COUCH, T.V. STERIO, BOOK CASE, TALKING TO OWNER SHE STATED THAT HER SON USES IT FOR LIKE A CLUB HOUSE, BUT DOES NOT STAY INSIDE, I DID EXPLAIN ISSUE ABOUT USING EXTENSION CORD, IF SON WANTED TO LISTEN TO MUSIC OR WATCH T.V. THIS COULD BE DONE BUT WOULD HAVE TO DISCONNECT AND REMOVE EXTENSION CORD, EXTENSION CORD CAN ONLY BE USED FOR TEMPORARY POWER ONLY AND NOT IN LIEU OF PERMANANT POWER, SHE STATED SHE WOULD MAKE SURE THIS IS DONE, OTHER ISSUES ON SITE ARE ALOT OF TRASH AND DEBRIS THROUGH OUT YARDS, ON ONE LOT IS A 30 AMP PEDSTAL FOR A MOBIL HOME, HAS A 3 SIDED GARAGE WITH ELECTRIC, SEPERATE METER, 100 AMP. DOES HAVE EXTENSION CORDS RUNNING THROUGH OUT GARAGE, ALSO MAIN HOUSE HAS SEPERATE METER, THERE IS ANOTHER MAIN SERVICE PANEL BUT METER HAS BEEN REMOVED FROM THIS ONE. MAIN SERVICE AT MAIN HOUSE HAS HAD WIRING ADDED TO IT FOR WASHING MACHINE, THIS HAS NOT BEEN PERMITTED, DUE TO THE WAY IT IS INSTALLED, SERVICE PANEL MISSING BLANK CAPS ALL MISSING,
03/28/2005 INSP - FOLLOW UP CODE ENFORCE GGOODMAN Approved 3/28/05 RE-VISITED SITE, MET WITH OWNERS, SAID THEY REMEMBERED C-13 FROM FIRST INSP. SAID SOME CHANGES HAD BEEN MADE, AND THAT THEY HAD NOT HEARD FROM DNR FOR SOME TIME. INSP HURD TOLD THEM THAT WE WERE BACK OUT TO SEE IF ANY CORRECTIONS HAD BEEN MADE. CHECKED THE ELECTRICAL SERVICE TO THE MAIN HOUSE, WHICH RAN OFF OF THE MAIN SERVICE TO THE PROPERTY WHICH WAS ACTUALLY LOCATED AT THE SHOP/GARAGE. OWNER MENTIONED THAT SERVICE AT HOUSE HAD BEEN CORRECTED BY AN ELECTRICIAN. IT DID APPEAR TO HAVE BEEN DONE CORRECTLY, NO APPARENT PROBLEMS. CHECKED HOTWATER HEATER, NO CHANGES HAD BEEN MADE.WATER HEATER STILL MISSING DRAIN PIPE, COLD WATER SHUT OFF, AND FLUE PIPE NEEDS TO BE SEALED AT JOINTS. ADDED ROOF OVER GARAGE STORAGE NEEDS TO BE REMOVED,IMPROPERLY BUILT, NOTHING CORRECT ABOUT IT. RAFTERS OVER SPAN AND NOT CONTINUOS. NO TIE DOWN CONNECTORS. RAFTERS LIE ON ACTUAL ROOF OF A STORAGE SHED. ELECTRICAL PEDESTAL FOR SHOP PROBABLY WORK WITHOUT PERMITS, AND PEDESTAL NOT PROPERLY MOUNTED OR SECURED. WOOD PEDESTAL DETERIORATING. MAIN ELECTRICAL SERVICE AT SHOP (METERED PANEL) HAS EXPOSED WIRING, KNOCK OUTS AND DEAD PLATES MISSING. OBVIOUS TRASH,DEBRIS, AND JUNK MOTOR VEHICLES. STORAGE SHED NOT BUILT CORRECTLY, STUDS IN BEARING WALLS OVER SPANNED, RAFTERS OVER SPANNED, AND CENTER BEARING 1 X 6 INADEQUATE. WILL COMPLETE FURTHER RESEARCH/ NOV TO FOLLOW

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T04DV00155
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
02/07/2008 VIOLATION CLOSED
02/07/2008 RESEARCH