Case: T04DV00062

Parcel: 111080860

Inspection Status: Compliance

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Date Description Inspector Results Comments
11/29/2004 INSP - FOLLOW UP CODE ENFORCE Compliance VISITED SITE ON FW/UP INSP. MET WITH OWNER & CONTRACTOR, ALSO ON SITE WAS JERRY ORTA. REMAINING VIOLATION, MARKING OF BREAKER PANEL & RETURN AIR & COMBUSTION AIR ON HOT WATER HEATER DOOR HAS BEEN ABATED. ONE OTHER ELECTRICAL PROBLEM WAS IDENTIFIED BY INSP. ORTA - 30 AMP BREAKER HAD UNDER SIZED WIRE. DEFICIENCY WAS POINTED TO OWNER AND CONTRACTOR TOOK CARE OF PROBLEM, 30 AMP BREAKER WAS REPLACED WITH 20 AMP BREAKER & NOW MATCHES WIRE SIZE. LOSE RECEPTACLE IN FURNACE CLOSET WAS ABATED AS WELL. OWNER HAS COMPLIED, PICTURES WERE TAKEN. CLOSE CASE.
10/11/2004 INSP - FOLLOW UP CODE ENFORCE Approved VISITED SITE ON FW/UP INSP. NO ONE HOME, LEFT MESSAGE REQUESTING INFORMATION ON REMAIN VIOLATION. INTERIOR & EXTERIOR PANELS NOT MARK FOR BRANCH CIRCUITS OPERATIONS, LEFT CELL NUMBER FOR RETURN CALL. VIOLATION ABATEMENT AT 95%.
08/24/2004 INSP - FOLLOW UP CODE ENFORCE Correction Required FU/UP INSPECTION ENERGY SOURCE ELECTRIC LIC #ROC190818
VISITED SITE ON FOLLOW UP INSPECTION. OWNER SUBMITTED COPY OF ELECTRICAL REPAIRS.
1. INSTALL SUB PANEL 60 AMP W/BREAKER.
2. INSTALL 2 WIRE RECEPTICLE THROUGHOUT STRUCTURE.
3. INSTALLED GFIC IN KITCHEN.
4. TROUBLE SHOOT 2 CIRUITS DATED 7-14-07 NC 3822
ISSUES ON NOV ABATED AS FOLLOWS:
1. NEW FLOORING THROUGHTOUT
2. NEW BATHROOM WINDOW INSTALLED.
3. NEW WINDOW CRANKS THROUGHOUT STRUCTURE
4. NEW CEILING LIGHT FIXTURES IN KITCHEN.
5. NEW GAS RANGE
6. ALL 3 PRONG RECEPTACLES REPLACED.
7. NEW GFIC RECEPTACLES IN KITCHEN.
8. NEW SHOWER ENCLOSURE W/TUB LAVE SINK AND TOILET.
9. NEW LATCHING HARDWARE FOR SLIDING GALSS DOOR.
10. NEW HOTWATER HEATER DOOR, LACKING COMBUSTION AND RELIEF VENTS HOLES WERE DRILLED THROUGH DOOR ARE NOT ADEQUATE FOR NEED VOLUME OF AIR REQUIRED FOR COMBUSTION AIR AND RELIEF.
11. OLD 60 FUSE BOX REMOVED AND NEW SUBPANEL INSTALLED W/BREAKERS. BREAKERS LACKING ASSIGNMENT OF CIRCUITS AND AS WELL AS EXTERIOR PANEL.
08/09/2004 INSP - FOLLOW UP CODE ENFORCE Approved VISITED SITE ON FW/UP INSP, STRUCTURE IS STILL VACANT & SECURED AT THIS TIME. HAVE BEEN CONTACTED BY OWNER, STATED OWNER WILL BE MOVING BACK TO TUCSON & INTENDS TO REOCCUPY STRUCTURE, STRUCTURE WILL NO LONGER BE USED AS RENTAL PROPERTY. PLANS TO REOCCUPY IN SEPT. REMODEL OF STRUCTURE AT 85% COMPLETION. NEW INSTALLATION OF
(1) CERAMIC TILE THROUGHOUT STRUCTURE.
(2) NEW BATH TUB, SINK & TOILET.
(3) NEW CLOSET DOORS
(4) NEW BLOCK WALL AROUND BACK & SIDE YARD NORTHSIDE.
(5) ENTIRE STRUCTURE HAS BEEN STUCCOED & TEXTURED, LACK PAINT.
(6) CARPORT HAS BEEN PAINTED.
(7) NEW 6FIC RECEPTACLES HAVE BEEN INSTALLED.
OWNER HAS ELECTRICAL CONTRACTOR WORKING ON IDENTIFYING BRANCH CIRCUITS WILL EXTEND ABATEMENT TIME, PICTURES WERE TAKEN WILL DO FW/UP IN 30 DAYS.
04/22/2004 INSP - FOLLOW UP CODE ENFORCE Approved OWNER MAKING PROGRESS
VISITED SITE ON FOLLOW UP INSPECTION, STRUCTURE IS VACANT & SECURED AT THIS TIME, RENOVATION OF STRUCTURE IN ON GOING. EXTERIOR BLOCK SURFACE HAS BEEN STUCCOED, NEW FACSIA BOARD INSTALLED. GARAGE HAS BEEN PAINTED. BLOCK WALL AT 80% COMPLETIONS. ALL FLOORING HAS BEEN REMOVED ALONG WITH TOILET & LAVE SINK. ABATEMENT IS MOVING FORWARD WILL DO FOLLOW UP IN 30 DAYS. PICTURES WERE TAKEN. DO 30 DAY FOLLOW
03/22/2004 INSP - FOLLOW UP CODE ENFORCE Violation VACANT & SECURED
VISITED SITE, MET WITH OWNER FROM OUT OF STATE (CAL) AT PROPERTY. OWNER WAS IN TOWN DUE TO COURT PROCEEDINGS. TENANT WAS REMOVED FROM RESIDENCE BY COURT ORDER. TENANT WERE FOUND TO BE USING SAME TACTICS AT 3 OTHER PROPERTIES. REPORTING AND DAMAGING PROPERTY TO GET OUT OF PAYING RENT. STRUCTURE IS VACANT & SECRUED AT THIS TIME. SOME PROGERSS HAS BEEN MADE ON VIOLATIONS LISTED ON NOV.
(1) ELECTRICAL CONTRACTOR DOING ACCESSMENT OF ELECTRIACL REPAIRS NEEDED.
(2) ACCESS CONTROL: NOT ABATED-LOOKING FOR LATCHING HARDWARE
(3) RODENT CONTROL: ABATED
(4) BUILDING INTERIOR FIRE SAFETY: PAINTED WINDOWS ABATED & WINDOW CRANK MECHANISUMS ON ORDER.
(5) PLUMBING SYSTEMS: TUB, TOILET, LAVE SINK & NEW CABINET HAVE BEEN ORDERED.
(6) INTERIOR SURFACES:DETERIORATED FLOORING HAS BEEN REMOVED. WORK HAS STARTED ON WALLS
(7) EXTERIOR SURFACES: WINDOW NOT ABATED.
(8) BULK OF COMBUSTABLE TRASH & DEBRIS HAS BEEN REMOVED.
BLOCK WALL IS 70 % COMPLETED. OWNER MAKING PROGERSS. ABATEMENT TIME HAS BEEN EXTENDED. WILL DO 30 DAY FOLLOW UP.