Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

01/21/2004

Applicant:

IZAGUIRRE ELSA SIERRA & CRUZ YENY JT/RS

Description:

COMPLAINT:MIN HOUSING-ROACH INFESTATION ALSO BATHROOM LEAKS. KITCHEN CABINETS ARE ALSO ROTTED.

Outstanding Inspections

Case Number: T04DV00062
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
02/09/2004 INSP - INITIAL CODE ENFORCMENT HLOPEZ Violation ATTEMPTED CONTACT WITH TENANTS, NO ANSWER, MESSAGE MACHINE PICKED UP, LEFT OFFICE NUMBER FOR CONTACT. VISITED SITE WALKED PROPERTY WITH TENANT. ELECT-100 AMP RUNNING BOTH STRUCTURES. BREAKER NOT MARKED, EXPOSED ELECT CIRCUIT-ROMEX COMING OUT EXTERIOR LIGHT FIXTURE. LIVING RM-3 PRONG RECEP. LACKING GRD. & NOT SECURED TO KITCHEN WALL-3 PRONG RECEPT NOT GRD. LACKING GFIC REC. BY KITCHEN DOOR NOT WORKING HALLWAY FOUND FUSE BOX WITH EXPOSED ELECTRICAL CONDUCTORS OVERSIZE FUSE PROTECTION #12 WILL & 30 AMP FUSE'S SCREW IN FUSE TYPE NW BDRM-3-PRONG RECEP. LACKING GR & 1-2 PRONG RECEP. FURNACE RM EXPOSED ELECTRICAL FOR RECEP & IS GRD. BATHRM LIGHT SWITCH NOT WORKING PROPERLY & LACKING G.F.I.C. COVER PLATE IS BROKEN MASTER BDRM, 1-2 PRONG RECEP 2-3 PRONG-LACKING GRD. EGRESS MASTER BD RM-SLIDING GLASS DR. LACKING LOCKING MECHANISM. NORTH WINDOW PAINTED SHUT, BOTH RM WINDOW'S DO NOT OPEN LACKING WORKING CRANK MECHANISMS. HW BEDRM WINDOW CRANK NOT OPERATIONAL. PLUMBING-KITCHEN SINK CABINET SHOWS WATER DAMAGE, NOT LEAKING AT THIS TIME. BATH ROM LAVE. SINK PLUMBING LEAKS, ESCUSCHAN PLATE MISSING FROM MIXING VALVE, MIXING VALVE MISSING HANDLE, CAN ONLY USE VISE GRIPS TO TURN ON WATER. FLOORING IN BATH ROOM IS PEELING UP, MOST NOT HOLDING. BEHIND TOILET WALL BADLY DETERIORATED, BATH RM WINDOWN BROKEN, POSSIBLE HOLE BY DOOR TILE CRACKED & GIVES WHEN STEPPED ON. MECHANICAL-FURNACE WAS FOUND WITH DAMPER INSTALLED IN DUCT WORK, EVIDENCE OF NEW GAS LINE HAS BEEN INSTALLED ORIGINAL VALVE STILL ON,. ILLEGALLY INSTALLED FLEX INTO FURNACE AREA. FURNACE IN NEED OF SERVICING LARGE AMOUNTS OF LINT IN FURNACE & AROUND DOOR OPENING, CHECK FOR PERMIT. RODENT INFESTATION EVIDENCE OF MICE DROPPINGS FOUND THROUGHOUT KITCHEN CABINETS. LARGE AMOUNTS OF TRASH & DEBRIS IN BACK YARD OWNER IN PROCESS OF BUILDING 6' BLOCK WALL.
02/09/2004 INSP - INITIAL CODE ENFORCMENT HLOPEZ Violation CONTACTED INSP. II INFORMED HIM OF HAZARDOUS CONDITION OF FURNACE. DECISION TO ISSUE 23-HR. NOTICE TO OWNER & POST NOTICE & HAND DELIVER TO OWNER REP. WAS MADE. INFORMED INSP. II OWNER REP. IS IN PROCESS OF CONTACTING CONTRACTOR. SPOKE WITH OWNERS REP. EFRIN. CONTACT WITH CONTRACTOR HAS BEEN MADE IS SCHEDULED TO BE ON SITE BETWEEN 8:00 AM & 9:00 AM, ASKED INSP. TO NOTIFY TENANTS,STATED TENANTS WILL NOT ALLOW WORKERS TO ENTER BACKYARD TO FINISHED BLOCK WALL AND WILL NOT REMOVE PIT BULL DOG FROM BACK YARD. HAS MADE ATTEMPTS TO MAKE REPAIRS ON WATER FIXTURES & WAS NOT ALLOWED ENTRY. INSTRUCTED EFRIN TO POST 48 HR, NOTICE TO ENTER UNIT FOR REPAIRS & IF NOT ALLOWED TO ENTER, MAKE CONTACT W./INSP. SPOKE WITH TENAT, I FORMED AN ARRANGEMENT TO ALLOW OWNER REP. OR ANY OTHER PERSON SENT TO MAKE REPAIRS & DO WORK ON PROPERTY ACCESS TO INTERIOR & EXTERIOR OF STRUCTURE. TENANT STATED HE COULD COOPERATE. MADE CONTACT WITH OWNER IN CALIFORNIA INFORMED HER OF HAZAROUDS CONDITION OF HEATING APPLICANCE AND OTHER VIOLATION ON PROPERTY STATES TENANTS ARE UNWILLINGLY TO COOPERATE & ARE SEVERAL MONTHS BEHIND ON RENT. REFERRED OWNER TO SOUTHWEST HOUSING AUTHORITY. INFORMED OWNER SHE WOULD BE RECEIVING N.O.V. AFTER RESEARCH HAD BEEN COMPLETED. INFORMED HER AS LONG AS THEIR WAS PROGRESS ON VIOLATION, CITY WOULD BE WILLINGLY TO EXTEND ABATEMENT TIME.

Completed Inspections

Case Status: COMPLIAN
Case Number: T04DV00062
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
11/29/2004 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Approved VISITED SITE ON FW/UP INSP. MET WITH OWNER & CONTRACTOR, ALSO ON SITE WAS JERRY ORTA. REMAINING VIOLATION, MARKING OF BREAKER PANEL & RETURN AIR & COMBUSTION AIR ON HOT WATER HEATER DOOR HAS BEEN ABATED. ONE OTHER ELECTRICAL PROBLEM WAS IDENTIFIED BY INSP. ORTA - 30 AMP BREAKER HAD UNDER SIZED WIRE. DEFICIENCY WAS POINTED TO OWNER AND CONTRACTOR TOOK CARE OF PROBLEM, 30 AMP BREAKER WAS REPLACED WITH 20 AMP BREAKER & NOW MATCHES WIRE SIZE. LOSE RECEPTACLE IN FURNACE CLOSET WAS ABATED AS WELL. OWNER HAS COMPLIED, PICTURES WERE TAKEN. CLOSE CASE.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T04DV00062
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
02/19/2004 NOTICE OF VIOLATION ISSUED
12/02/2004 VIOLATION CLOSED
03/08/2004 SITE VISIT/INSPECTION MADE. SEE INSPECTION RESULTS AND NOTATIONS FOR SPECIFIC INFORMATION.

Documents

File Name Document Type  
2004-12-01 001.JPG None VIEW
2004-12-01 002.JPG None VIEW
MVC-001S.JPG None VIEW
MVC-002S.JPG None VIEW
MVC-003S.JPG None VIEW
MVC-004S.JPG None VIEW
MVC-001S.JPG None VIEW
MVC-002S.JPG None VIEW
MVC-003S.JPG None VIEW
2004-08-27 001.JPG None VIEW
2004-08-27 002.JPG None VIEW
2004-08-27 003.JPG None VIEW
2004-08-27 004.JPG None VIEW
2004-08-27 005.JPG None VIEW
2004-08-27 006.JPG None VIEW
2004-08-27 007.JPG None VIEW
2004-08-27 008.JPG None VIEW
2004-08-27 009.JPG None VIEW
2004-08-27 010.JPG None VIEW
2004-08-27 011.JPG None VIEW
2004-08-27 012.JPG None VIEW
MVC-033S.JPG None VIEW
MVC-028S.JPG None VIEW
MVC-029S.JPG None VIEW
MVC-030S.JPG None VIEW
MVC-031S.JPG None VIEW
MVC-033S.JPG None VIEW
MVC-034S.JPG None VIEW
MVC-035S.JPG None VIEW
MVC-036S.JPG None VIEW
MVC-037S.JPG None VIEW
MVC-038S.JPG None VIEW
MVC-039S.JPG None VIEW
MVC-040S.JPG None VIEW
MVC-042S.JPG None VIEW
MVC-043S.JPG None VIEW
MVC-044S.JPG None VIEW
MVC-045S.JPG None VIEW
MVC-046S.JPG None VIEW
MVC-047S.JPG None VIEW
MVC-048S.JPG None VIEW
MVC-049S.JPG None VIEW
MVC-050S.JPG None VIEW
MVC-051S.JPG None VIEW
MVC-052S.JPG None VIEW
MVC-053S.JPG None VIEW
MVC-054S.JPG None VIEW
MVC-055S.JPG None VIEW
MVC-056S.JPG None VIEW
MVC-057S.JPG None VIEW