Permit: T04CM05376

Parcel: 141148150

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T04CM05376

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/24/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
1) PLUMBING FINAL IS OK
2) OK FOR C OF O
05/19/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* 1) HAVE ALL APPLIANCES INSTALLED AND HAVE CERTIFICATIONS FOR ALL IN HOUSE BACKFLOW DEVICES. 2) ALL INDERECT DRAINS TO BE SEPARATE OVER 5' TRAPPED & OVER 15' TRAPPED AND VENTED. 3) H20 SUPPLY TO BACKFLOW DEVICES TO BE FULL SIZE RIDGID PIPING. 4) MAKE WATER TIGHT FIXTURES. 5) ALL CLEANOUTS TO HAVE THREADED PLUGS WITH MATCHING SCREWS & CLEANOUT COVERS. 6) FLOW CONTROL TO BE VENTED CORRECTLY. 7) PROVIDE CORRECT TRANSITION FROM 2" TO 3' AT FLOW CONTROL. 8) SEPARATE CONDENSATE FROM DRAIN AT FRONT 3-COMP SINK LOCATION. 7) CORRECT DRAINAGE AT LAV.