Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/14/2005 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :*APPROVED-IN THE FUTURE-(1) KEEP ALL SPECIAL INSPECTION FIELD REPORTS ON SITE WITH C.O.T. REPORTS. (2) KEEP TENDONS AS STRAIGHT AS POSSIBLE. THEY SHOULD ONLY CURVE (WOBBLE) AROUND OPENINGS, PIPES, ETC. | |
| 01/12/2005 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* REFERENCE 51/35DI PORCHES MISSING 2) REFERENCE 1 & 2/5DI EXCESSIVE EXPOSED STRAND AT TENDON STRESSING ENDS. 3) REFERENCE GSN/5DI 6" CLEAR REQUIRED FROM TENDON TO SLABEDGE THIS INCLUDES EDGES & BLOCKOUTS. 4) IMPROPER CLEARANCE/ ?? @ SLAB ELEVATION CHA? REF 8/SDI 5) KEEP TENDON PROFILE FLAT AT SHOWERS. 6) INSTALL HD & PER MANUFACTURER'S SPECIFICATIONS |