Permit: T04CM04907

Parcel: 136055350

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
01/14/2005 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*APPROVED-IN THE FUTURE-(1) KEEP ALL SPECIAL INSPECTION FIELD REPORTS ON SITE WITH C.O.T. REPORTS. (2) KEEP TENDONS AS STRAIGHT AS POSSIBLE. THEY SHOULD ONLY CURVE (WOBBLE) AROUND OPENINGS, PIPES, ETC.
01/12/2005 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999* REFERENCE 51/35DI PORCHES MISSING 2) REFERENCE 1 & 2/5DI EXCESSIVE EXPOSED STRAND AT TENDON STRESSING ENDS. 3) REFERENCE GSN/5DI 6" CLEAR REQUIRED FROM TENDON TO SLABEDGE THIS INCLUDES EDGES & BLOCKOUTS. 4) IMPROPER CLEARANCE/ ?? @ SLAB ELEVATION CHA? REF 8/SDI 5) KEEP TENDON PROFILE FLAT AT SHOWERS. 6) INSTALL HD & PER MANUFACTURER'S SPECIFICATIONS