Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T04CM04866
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/15/2004 | MECHANICAL - FINAL | Approved | IVRS - Inspection :*/ALL CORRECTIONS HAVE BEEN MADE. | |
11/05/2004 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)PROVIDE A COVER OVER CANVAS CONNECTOR. 2)INSTALL CONDENSATE DRAIN LINES 3)SECURE REFRIGERATION LINES 4)DO NOT USE A 30 AMP FUSE FOR CONDENSOR. FO NOT USE WHITE WIRE FOR HIGH VOLTAGE. TAPE BOTH ENDS OF WIRE BLACK 5)PROVIDE FRESH AIR INTAKES ON A/C UNITS 6)INSTALL THE HOODS OVER FLUE VENTS ON GAS PACKS |