Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM04510
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/14/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | ||
12/09/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
12/09/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | APPROVED IN ERROR 1) FROM LAST INSP ITEMS 2,3,4, NOT COMPLETE. 2) ADD WIND BRACE TO EAST WALL. 3) NAIL OFF ALL MISSED AREAS ON ROOF WEST SIDE THE MOST MISSING NAILS | |
12/07/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WIND BRACES REQUIRE TWO NAILS AT ENDS 2) NAILS PROTECT PLUMBING AND ELECTRIC CONDUIT FROM OUTSIDE 3) MISSING KINGS AT 6 DEGREE WINDOW OPENING 4) PROVIDE EPOXY RETROFIT FOR HOLDOWN REAR OF HOUSE 5) STRAP CORNERS THAT ARE NOT CABIN TIED 6) STOPPED INSPECTION TO MANY ITEMS 7) HAVE SUPERVISOR WALK HOUSE BEFORE RECALL |
|
12/06/2004 | EXT METAL CLIPS/EXT SHEATHING | Cancelled |