Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/06/2005 | PLUMBING - SEWER HCS CONNECT | Approved | IVRS - Inspection :* | |
| 03/01/2005 | PLUMBING - SEWER HCS CONNECT | Partial Approval | 1) MANHOLE #1 TO MANHOLE #5 5 PSI AIR TEST OK 2) MANHOLE #1TO MANHOLE #9 4 PSI AIR TEST OK 3) MANHOLE #4 TO MANHOLE #6 4 PSI AIR TEST OK 4) MANHOLE #6 TO SOUTH EAST BLDG #3 4 PSI AIR TEST OK 5) MANHOLE #1 VACCUM TEST OK 6) MANHOLE #2 VACCUM TEST OK 7) MANHOLE #3 VACCUM TEST OK 8) MANHOLE #4 VACCUM TEST OK 9) MANHOLE #5 VACCUM TEST OK 10) MANHOLE #6 VACCUM TEST OK 11) SEWER AIR TESTING COMPLETE OK 12) WILL NEED REVISED APPROVED PLAN FOR ADDITION OF MANHOLE #6 AND PPEQ CERTIFICATE OF COMPLIANCE |
|
| 02/28/2005 | PLUMBING - SEWER HCS CONNECT | Partial Approval | 4" HCS CONNECTION AT SOUTH WEST CORNER OK | |
| 02/24/2005 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* MANHOLE #1 TO MANHOLE #2 4 PSI PRESSURE TEST OK. MANHOLE #2 TO MANHOLE #3 4 PSI PRESSURE TEST OK. MANHOLE #3 TO MANHOLE #4 4 PSI PRESSURE TEST OK. MANHOLE #4 6" HCS LATERAL TO BUILDING #2 4 PSI TEST OK. MANHOLE #4 6" LATERAL TO C/O 3A, 4" TO C/O RIM 44.94 TO NORTH END BLD #2. 4 PSI TEST OK |
|
| 02/18/2005 | PLUMBING - SEWER HCS CONNECT | Cancelled | IVRS - RI canceled | |
| 11/02/2004 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :*/8" SEWER FROM EXISTING MANHOLE #9 TO NEW MANHOLE #1, 8" SEWER FROM MANHOLE #1 EAST TO MANHOLE #5. FROM MANHOLE #1 NORTH TO 8" SEWER TO MANHOLE #2, FROM MANHOLE #2 TO MANHOLE #3 8" SEWER, FROM LATERALS, FROM MANHOLE #4 4" HCS LATERAL EAST 100', 6" HCS LATER 76.7 NORTH, 6" HCS LATERAL 34' WEST, FROM MANHOLE #2 6" HCS LATERAL 79' MORTH EAST. FROM MANHOLE #1 8" SEWER TO MANHOLE #5 OK. 1)WILL REQUIRE AIR TEST, MANDROL, VACUUM TEST AND VERIFICATION OF GRADE, WITH PDEQ CERTIFICATION AT LATER DATE | |
| 10/19/2004 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection :* | |
| 10/18/2004 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection :*/THERE IS A REVISED PLAN THAT SHOWS 5 NEW MANHOLES INSTEAD OF CITY APPROVED PLAN WITH 4 MANHOLES, THIS PLAN NEEDS TO BE CITY APPROVED AND ON SITE. ADDED MANHOLE IS BETWEEN #1 AND WHAT IS #2 ON 8/23/04 PLAN |