Permit: T04CM02883

Parcel: 13632002U

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
12/09/2005 BUILDING - FINAL Approved IVRS - Inspection :*
11/16/2005 BUILDING - FINAL Partial Approval IVRS - Inspection :*
1) ROOF SCUPPERS DRAINING ON EXT. LIGHT FIXTURES
2) MISSING ANTI-SIPHON ON HOSE BIB, NEXT TO ELECTRIC SERVICE PANEL
11/04/2005 BUILDING - FINAL Partial Approval IVRS - Inspection :*
1) REAR AND SIDE GFCI RECEPTACLES WON'T TRIP
2) H20 HTR FLUE NOT CONNECTED, REMOVE TAPE AT SINGLE TO DBL WALL CONNECTION
3) H20 IS OFF AT EAST H20 HTR
4) SECURE AND PROTECT A/C CONTROL WIRES AT EXTERIOR
5) SERVICE PANEL-WHITE WIRE IN HOT TERMINAL ?
6) RAISE DISPOSAL LINE AS HIGH AS POSSIBLE
7) 2 SINKS IN KITCHEN ONLY ONE IS PROTECTED WITH A PL TRAP
8) CAULK LOG LITER PIPE WHERE IT ENTERS THE FIREPLACES USE (FIRE PLACE CAULK) NOT FIRE CAULK
9) SCUPPERS AT EXT. LIGHTS