Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/09/2005 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 11/16/2005 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) ROOF SCUPPERS DRAINING ON EXT. LIGHT FIXTURES 2) MISSING ANTI-SIPHON ON HOSE BIB, NEXT TO ELECTRIC SERVICE PANEL |
|
| 11/04/2005 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) REAR AND SIDE GFCI RECEPTACLES WON'T TRIP 2) H20 HTR FLUE NOT CONNECTED, REMOVE TAPE AT SINGLE TO DBL WALL CONNECTION 3) H20 IS OFF AT EAST H20 HTR 4) SECURE AND PROTECT A/C CONTROL WIRES AT EXTERIOR 5) SERVICE PANEL-WHITE WIRE IN HOT TERMINAL ? 6) RAISE DISPOSAL LINE AS HIGH AS POSSIBLE 7) 2 SINKS IN KITCHEN ONLY ONE IS PROTECTED WITH A PL TRAP 8) CAULK LOG LITER PIPE WHERE IT ENTERS THE FIREPLACES USE (FIRE PLACE CAULK) NOT FIRE CAULK 9) SCUPPERS AT EXT. LIGHTS |