Permit: T04CM02883

Parcel: 13632002U

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/06/2005 FRAMING Approved IVRS - Inspection :*
1) LAST INSPECTION #2 (ITEM) FILL TUB WITH H20, CHECK FOR LEAK IN TUB SHOE, OK TO INSULATE RECALL PLUMBING
2) MORE NAILS IN SIDE BLOCKS SUPPORTING VIEGA LOGS, YOU USED GUN NAILS THEY ARE NOT 16D'S, THEY ARE 10D OR 12D
05/02/2005 FRAMING Not ready for Inspection IVRS - Inspection :* #1 LOW GAS PRESSURE TEST #2 TUBS TOO BE FILLED WITH H20 #3 ??? ROMEX AWAY FROM F/PLACE #4 GAS LINE TO F/PLACE FIRE BOX #5 CAN LIGHTS TO BE 12" FROM CLOSET SHELF #6 MORE NAILS IN BLKS. SUPPORTING VIEGA LOGS #7 HEARTH SAFETY STRIP TO GO 1/2 WAY UNDER F/P #8 EAST SIDE, DEN OUTLETS BEHIND ENTERTAINMENT UNIT #9 D.W VENT H20 TEST #10 LAST INSP. MISSED PA STRAP WEST WALL #11 FINISH LATH.
04/04/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) INSTALL GAS LINES AND FINISH H20 LINES
2) LATH TO BE UP TO AT LEAST 8'-0"