Permit: T04CM02613

Parcel: 138242310

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/13/2004 FRAMING Approved IVRS - Inspection :*
08/12/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) NAIL PROTECT WIRES WITHIN 1 1/4" OF WALL SURFACE 2) DOUBLE STUDS FOR NORTH GARAGE SHEARWALL NOT NAILED TO OSB AT 7" ON CENTER 3) SEAL STUCCO LATH HOLES ON NORTH WALL 4) SECURE RANGE CABLE WITHIN 8" OF BOX 5) PEX T ABOVE M. BR. NOT PROPERLY INSTALLED-TO FAR FROM FIITTING STOP 6) PLUMBING J HOOKS OUT OF WALL CAVITY 7) PROVIDE APRPOVED 8/A8A SHEARWALL REPAIR OF DAMAGED BY MECHANICAL