Permit: T04CM02431

Parcel: 10819009B


Addresses:

4798 N 1ST AV


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T04CM02431

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
01/31/2005 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
01/27/2005 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :* 1 1/2 COPPER FROM SOUTH WEST CORNER TO WASH RACK 55PSI AIR TEST OK. 2" PUMPED ABS FROM SUMP PUMP AREA TO TIE IN POINT AT SOUTH WEST CORNER OF BUILDING 6 PSI AIR TEST OK
01/05/2005 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*1) VENT FROM INTERCEPTOR, INSTALLED TO INSIDE BLDG, AND UP TO OVERHEAD OK 2) CONNECTION OF SS AND INTERCEPTED WASTE AT EXISTING MAIN OK. SADDLE TAP OK CONNECTIONS OK WATER TEST OK 3) OK TO COVER.
01/04/2005 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :* 1) GREASE WASTE IN APPARATUS ? OK THRU INTERCEPTOR AND RECONNECTED TO SS OK
NEED TO SEE VENT EXTENSION
NEED TO SEE SEWER TAP
2) 4"EXITING # 102 AND CONNECTED TO SS OK
3) SS FROM ROOM # 130 THRU APPARATUS BAY AND TO WITHIN FEET TEN FEET OF MAIN OK TO COVER 4) 2" PUMPED WASTE TO OUTSIDE APPARATUS BAY OK 5) REDLINES ON SITE.
12/08/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*/1)UNDERGROUND FOR TRENCH DRAIN AT EXTRACTOR OK. OK TO COVER, AIR TEST 6# OK
10/26/2004 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
10/25/2004 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*/1)GATES LOCKED NO ACCESS
10/14/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*/1)TRAINING WORK ROOM AND CLEAN UP-ABS DWV OK. WATER TEST ONE RISER TO TEN FEET OK. OK TO COVER
10/13/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*/ABS DWV FOR AREA EAST OF APPARATUS AREA OK. AIR TEST 5# OK. OK TO OUTSIDE BLDG. OK TO COVER.