Permit: T04CM02122

Parcel: 112073470


Addresses:

2926 E SYLVIA ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
11/19/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/16/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) 2 BOLTS BOTTOM PLATES EACH SHEARWALL SECTION AND INSTALL FHA STRAPS OUTSIDE BOTTOM PLATE AT PLUMBING AND ELECTRIC PENETRATIONS
2) NEED APPROVED TRUSS DRAWINGS
3) CROSS BRACE 1ST AND 3RD TRUSS AND MAXIMUM 25' OF RUN
4) NAILS SET TOO DEEP IN ROOF SHEATHING AND WALL SHEATHING (RENAIL ALL)
5) STOPPED INSPECTION