Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T04CM02033
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/29/2004 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :*/1)SOIL WATER TEST IS OK 2)ALL CORRECTIONS HAVE BEEN MADE. | |
| 11/29/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*/ 1) UNIT #3 WASTE AND VENT SYSTEM IS OK 2) GAS PRESSURE TEST IS OK 3) OVERHEAD WATER DISTRIBUTION IS OK 4) OK FOR DRYWALL UPON BLDG INSPECTION APPROVAL 5) NOTE: #4 LAVATORY TRAP ARM MAXIMUM SIZE IS 1 1/2" RETEST SYSTEM |
|
| 11/26/2004 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)SHALL PROVIDE TWO HOLE STRAPS FOR SECUREING GAS LINE. 10 MIL TAPE NOT ACCEPTED. 2)MIN SIZE OF TRAP ARM FOR LAVATORY IS 1 1/2" 3)SHALL PROVIDE PROPER DRAINAGE FITTINGS FOR KITCHEN RE VENT OR LOCATE HORIZONTAL VENT 6" ABOVE FLOOD RIM LEVEL 4)DWV APPEARS TO HAVE A LEAK ON 3" SAN TEE IN NORTH UNIT |