Permit: T04CM02033

Parcel: 138170440


Addresses:

338 E ELVADO RD #03

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
11/29/2004 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*/1)SOIL WATER TEST IS OK 2)ALL CORRECTIONS HAVE BEEN MADE.
11/29/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) UNIT #3 WASTE AND VENT SYSTEM IS OK
2) GAS PRESSURE TEST IS OK
3) OVERHEAD WATER DISTRIBUTION IS OK
4) OK FOR DRYWALL UPON BLDG INSPECTION APPROVAL
5) NOTE: #4 LAVATORY TRAP ARM MAXIMUM SIZE IS 1 1/2" RETEST SYSTEM
11/26/2004 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*/1)SHALL PROVIDE TWO HOLE STRAPS FOR SECUREING GAS LINE. 10 MIL TAPE NOT ACCEPTED. 2)MIN SIZE OF TRAP ARM FOR LAVATORY IS 1 1/2" 3)SHALL PROVIDE PROPER DRAINAGE FITTINGS FOR KITCHEN RE VENT OR LOCATE HORIZONTAL VENT 6" ABOVE FLOOD RIM LEVEL 4)DWV APPEARS TO HAVE A LEAK ON 3" SAN TEE IN NORTH UNIT