Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T04CM01885

Parcel: 13821030F


Addresses:

334 W LOS REALES RD


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T04CM01885

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/24/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
03/23/2006 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
IF CLEANOUT PLUG IS USED TO ATTACH COVER TO WALL, THEN THE PLUG MUST BE LISTED AND DESIGNED FOR SUCH USE.
PLASTIC VENT TERMINATIONS NEED TO BE PAINTED FOR UV PROTECTION.
LAVATORY FAUCETS, SPECIFICATIONS CALL FOR SYMMONS
PIC SPECS CALL FOR OFFSET TAIL PIECES.
03/17/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
03/09/2006 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
SUPPORT GAS PIPING BRANCHES TO FURNACES, AND SECURE W/2 HOLE STRAP. KEEP DRP LEGS OFF ROOF. GAS CARD LEFT.