Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/24/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 03/23/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* IF CLEANOUT PLUG IS USED TO ATTACH COVER TO WALL, THEN THE PLUG MUST BE LISTED AND DESIGNED FOR SUCH USE. PLASTIC VENT TERMINATIONS NEED TO BE PAINTED FOR UV PROTECTION. LAVATORY FAUCETS, SPECIFICATIONS CALL FOR SYMMONS PIC SPECS CALL FOR OFFSET TAIL PIECES. |
|
| 03/17/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 03/09/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* SUPPORT GAS PIPING BRANCHES TO FURNACES, AND SECURE W/2 HOLE STRAP. KEEP DRP LEGS OFF ROOF. GAS CARD LEFT. |