Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 02/20/2004 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000*/ WATRE TEST WASTE AND VENT UNDERSLAB UP TO CONNECTION TO EXISTING 2" VENT THRU ROOF APPROVED. CLOSET DEMO STUB 3" AND 4" TO BE GLUE STYLE PERM CAP. OK TO COVER. ALL DEMOED FIXTURES TO HAVE GLUE STYLE PERM CAPS. |
| 02/17/2004 |
PLUMBING - ROUGH, SOIL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) INSTALL UNDERSLAB ROUGH SOIL PER PLAN. 2) PERMANENTLY CAP OFF ALL FIXTURES THAT HAVE BEEN REMOVED OUT BELOW FINISHED FLOOR. 3) INSTALL H2O PIPING PER PLAN. |