Permit: T04BU02919

Parcel: 10602043D


Addresses:

3960 N STONE AV

Inspection Status: Approved

Inspection History: STORMWATER INSTALL OF CONTROLS

Date Description Inspector Results Comments
02/14/2005 STORMWATER INSTALL OF CONTROLS Approved Approved grading plan not on site. Ensure silt fence in maintained. Ensure storm water inspections are performed and documented. Ensure AZPDES authorization number is obtained and kept on site. No other storm water concerns at this time.
02/11/2005 STORMWATER INSTALL OF CONTROLS Correction Required Contacted contractor, no work has been performed on site since last inspection. Comments from previous inspection still need to be addressed.
02/09/2005 STORMWATER INSTALL OF CONTROLS Correction Required No approved SWPPP on site. No approved grading plan on site. Ensure silt fence is installed correctly. Remove or control all of the stock pile on the East side of property. Obtain AZPDES authorization numder and post it. Do storm water inspections and document them.
02/04/2005 STORMWATER INSTALL OF CONTROLS Denied Storm water controls not installed properly. Need to bury bottom of silt fence. Need to separate silt fence from security fence. Need to bend silt fence around SW corner of property, and at construction entraces. Need to have a copy of the SWPPP on site. Need to control silt from stock pile at East side of property. Call for re-inspection on Monday 2/7/05.