Case: T03VL00688

Parcel: 106120360


Addresses:

1454 W KILBURN ST

Inspection Status: Violation

Inspection History: INITIAL CODE VIOLATION

Date Description Inspector Results Comments
07/14/2003 INITIAL CODE VIOLATION Violation DAMAGE REPORT:
CAUSE: SERVICE ENTRANCE CONDUCTORS SHORTED OUT AND FUSED JUST PAST WEATHER HEAD IN RISER;
LOCATION: EXTERIOR EAST WALL SERVICE LOCATION;
ELECTRICAL: TWO-WIRE SERVICE 120V 30 AMP, APPEARS WIRES FUSED TOGETHER IN RISER - MAY HAVE BEEN TENSION ON DROP.
30 AMP SERVICE HAS NO NEUTRAL CONNECTION OR LANDING IN 30 AMP SWITCH, DOUBLE LUGGING ON SECONDARY #6 WIRES AND #10 WIRE WRAPPED AROUND SIREN. 30 AMP FUSES FEEDING PORCELAIN LIGHT AND RECEPTACLE.
ALL OF THE PROBELMS ABOVE AND AGE CONSTITUTE REQUIREMENT FOR A SERVICE UPGRADE THIS SERVICE WILL NOT BE RENERGIZED.
SUMMARY: A PERMIT FOR A SERVICE UPGRADE REQUIRED AND AN INSPECTION IN ORDER TO RE-ENGERIZE. OBTAIN PERMIT AT 201 N STONE AV. NOTICE OF DAMAGE GIVEN TO ELENA RUSSELL OWNERS EMPLOYEE.