Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T03PL01929
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/13/2004 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000* | |
12/22/2003 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999* 1) NO PRESSURE TEST. 2) DIELECTRIC UNION REQUIRED BETWEEN SHUTOFF & FLEX CONNECTOR. 3) APPLIANCE & WATER HEATER & FURANCE CONNECTORS OK. | |
11/19/2003 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*/ 1) MUST PROVIDE AIR PRESSURE TEST ON SYSTEM 10 LBS MIN. AT TIME OF INSPECTION. 2) MUST USE APPROVED FLEX CONNECTOR FOR TRAILER USE AT SERVICE CONNECTION. 3) MUST PROVIDE AGA OR CSA SHUT OFF VALVE AT HOUSE SERVICE. 4) MUST REMOVE UNION IN LINE AND PROVIDE RIGHT AND LEFT HAND NIPPLE. 5) NOTE: CHECK ALL APPLIANCES FOR ANY CODE VIOLATIONS. |