Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 06/16/2003 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/ 1) 14 PSI TEST IS OK 2) ALL CORRECTIONS HAVE BEEN MADE. CONFIRMED PETITION OF APPEAL 3) LEFT GAS CARD |
| 06/12/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) MUST USE REQUIRED TEST GAUGE FOR SYSTEMS REQUIRING 10 POUND OR LESS IN 1/10 INCREMENTS 2) CAN NOT RUN P & T DRAIN UP THRU ROOF 3) WHEN P & T DRAIN CAN NOT GO TO DAYLIGHT THEN A VARIANCE FORM MUST BE OBTAIN AND ALTERNATE METHOD OF INSTALLATION APPROVED BY CODES ADMINSTRATOR AND THIS FORM MUST BE ON SITE AT TIME OF INSPECTION 4) OK TO BACKFILL TRENCH |