03/19/2003 | PLUMBING - FINAL | Approved | 1.) PERMIT NUMBER FOR NEW SINK TO3PL00518. 2.) INDIRECT WASTE PIPING CORRECTED OK 3.) NEW SINK INSTALLED OK 4.) EXPANSION TANK OK 5.) UNION REMOVED FROM GAS LINE. 6.) OK FOR C OF O PENDING ANY OTHER INSPECTION. |
|
03/18/2003 | PLUMBING - FINAL | Not ready for Inspection | PLEASE READ COMPLY WITH ALL NOTES FROM MARCH 14. | |
02/20/2003 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection 0000* 1.) please secure permit for new plumbing 2.) review indirect waste piping 94 upc 3.) review table 3-1 hangers and supports 4.) water heater requires expansion tank. 5.) provide certification for rppbp rec'd ok 6.) remove open drain at hand sink 7.) flex connection (gas) only for appliance connector 8.) remove and plug unused gas connections 9.) it appears that utility sink has been added this requires permit and inspection. 10.) what method of backflow protection is employed at ice maker. |