Case: T03DV01146

Parcel: 130056560


Addresses:

2833 E MENOR SV

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
01/09/2005 INSP - INITIAL CODE ENFORCMENT Approved 1/9/04 REVISITED SITE, TOOK PICTURES, REVISITED SITE TO DO FOLLOW UP ON REINSPECTION OF ISSUES THAT WERE EXPLAINED TO RESIDENTS ON 1/8/04 BY INSP II RICK SALDATE, RESIDENTS WERE TO REMOVE ITEMS FROM HALLWAYS (2) AND ALSO CLEAN CENTERS OF BEDROOMS AND LIVING ROOM SO AS TO PROVIDE SAFE AND RAPID EGRESS IN CASE OF FIRE OR PANIC, ALSO TO CHECK AND SEE THAT RESIDENTS HAVE NOT DOUBLE LUGGED 60 AMP SERVICE PANEL TO SUPPLY POWER TO ELECTRIC. HOT WATER HEATER THAT HAS BEEN INSTALLED ( NO PERMIT FOR INSTALLATION) ALSO GLEN DAVRIA FROM TFD IS ON SITE, TO DO THEIR INSPECTION, MET WITH RESIDENTS AND WALKED UNIT, ALL HALLWAYS AND CENTERS OF BEDROOMS AND LIVING ROOM HAS BEEN CLEARED, EXTENSION CORDS HAVE BEEN REMOVED, CHECKED ELECTRICAL SERVICE PANEL, DOUBLE LUGGING FOR HOT WATER TANK HAS NOT BEEN RECONNECTED AT THIS TIME, SO RESIDENTS HAVE DONE WHAT WAS ASKED OF THEM.
01/14/2004 INSP - INITIAL CODE ENFORCMENT Correction Required 1/8/04, VISITED SITE, TOOK PICTURES, MET WITH MARTIN ROMERO ON SIGHT, UPON ARRIVING COULD SEE PROPERTY IS IN A STATE OF DETERIORATION AND DILAPIDATION, FENCING SURROUNDING PROPERTY IS MADE OF ALL DIFFERENT SORTS OF MATERIALS, RESIDENT JOHN KELLERSMAN CAME OUT AND WHILE TALKING TO JOHN I ASKED IF HE HAD ALL UTILITIES CONNECTED AND JOHN STATED NO THEY DO NOT HAVE NATURAL GAS SUPPLY CONNECTED, I ASKED HOW LONG THEY HAVE BEEN WITH OUT GAS JOHN STATED ABOUT 2 YEARS, METER GONE, WILL NEED RECONNECT PERMIT, AS WALKING ON TO PROPERTY COULD SEE MEGA TRASH AND DEBRIS EVERY WHERE, APPEARS TO HAVE ANY THING AND EVERY THING ON PROPERTY, TREE HAS BEEN BUILT ALSO, KIDS USE TREE HOUSE AS CLUB HOUSE, STATED NO ONE STAY'S IN TREE HOUSE, ALSO BUILT WORK AREA, ROOF ON WORK AREA LOOKS AS IF IT IS READY TO COLLASPE, BOWING DOWN WARD IN MIDDLE, NOT BUILT CORRECTLY, WILL NEED TO BE REMOVED, EXTERIOR SHOWS 13 VEHICLES ON SITE, NONE OF WHICE IS RUNNING OR CURRENTLY REGISTERED,
SOUTH SIDE OF STRUCTURE HAS OPEN AND EXPOSED WIRING AT PORCH LIGHT FIXTURE, HAS EXTENSION CORD RUNNING FROM EAVE TO POWER STRIP, HAS EXTENSION CORD GOING TO HOME MADE WORK SHED, THERE ARE NUMEROUS AREAS THAT HAS EXPOSED WIRING, EXTENSION CORDS, POWER STRIP CONNECTORS, EXTRA CONVENIENCE OUTLETS INSTALLED, NO COVER PLATES, EXTERIOR WEST SIDE OF STRUCTURE HAS EXPOSED WIRING HANGING FROM EAVES, ELECTRICAL HOT WATER TANK HAS BEEN INSTALLED, NO PERMIT, HAZARDOUS CONNECTIONS, OPEN AND EXPOSED, FRONT OF HOT WATER TANK MISSING ELECTRICAL COVER PLATES, WIRES COMMING THROUGH WALLS FOR A 4 GANG CONVENIENCE OUTLET BOX TO WASHER, WALLS HAS HOLES KNOCK THROUGH NOT RESEALED, BOTTOM OF WALL ON WEST SIDE HAS APPOX. 1'x3' OPENING WHERE PART OF WALL IS MISSING, IN SAME ARTEA HAS OPEN SEWER LINE CAP MISSING, WEATHER PROTECTION MISSING AROUND DOORS, HAS APPOX. 6'X4' PIECE OF WOOD ON WAY IN HALL WAY WHERE A HEATER HAS BEEN REMOVED, SLIDING GLASS DOOR AT EAST END OF HALL WAY MISSING PART OF FRAME, DOOR DOES OPEN FOR EGRESS, BEDROOMS HAS CLOTHES AND DEBRIS SCATTERED ABOUT ON FLOOR, DRESSERS, BEDS, THROUGHOUT, WILL NEED TO BE CLEANED AND REARRANGED FOR PROPER EGRESS, ALL ROOMS BUT ONE HAS WINDOWS THAT OPERATE FOR EGRESS, THE ONE BEDROOM SOUTHEAST CORNER, THAT HAS BEEN CREATED BY MOVING AND OR TOTALLY REMOVING WALLS HAS NO EGRESS, AND ON SOUTH WALL HAS PLYWOOD WHICH HAS OPENINGS TO EXTERIOR, ALOT OF DEBRIS, COLTHING SCATTERED ABOUT, HALLWAY GOING NORTH AND SOUTH HAS OPENING UP INTO ATTIC (CRAWL SPACE, NOT SEALED, ALSO DRYWALL ON CEILING HAS NOT BEEN FINISHED NO TAPING OR SEALING OF JOINTS, HOLES IN WALLS THROUGH OUT, HEATER AT NORTH END OF HALLWAY NOT OPERABLE, BEDROOM ON NORTH EAST CORNER, WINDOWS OPERATE, HAS METAL SHEATING LAYING UP AGAINST WINDOWS CREATES EGRESS PROBLEM, BEDROOM CLOSET HAS COOLER CONTROLS IN STALLED, WILL NEED TO BE REWIRED PROPERLY, INTERIOR WALLS DETERIORATED AND SEPERATING, BATHROOM SINK CABINET VANITY HAS HOLES UNDERNEITH GOING ALL THE WAY THROUGH THE WALL INTO KITCHEN, BATH TUB, SHOWER AREA LACKS WALL PROTECTION, ALLOWING WATER TO ENTER INTO WALL AND DETERIORATE STRUCTURE, HAS ABSORBENT MATERIALS INSTALLED ON WALL, BATH TUB IS MISSING OVERFLOW CAP, BATHROOM WINDOW FRAME WHERE WINDOW SITS IN FRAME IS SEPERATING AND SEPERATING ALLOWING LIGHT, WATER AND ALL ELEMENTS TO ENTER FROM OUTSIDE, TO DETERIORATE STRUCTURE, ELECTRICAL SYSTEM ON INTERIOR, ROMEX RUNNING TO KITCHEN LIGHT FIXTURE, INSTALL ELECTRICAL BOXES, MOUNTED TO WALL NOT PROPERLY INSTALLED, USING MANY EXTENSION CORDS, AND ELECTRICAL POWER STRIPS, OPEN AND EXPOSED WIRING, KITCHEN COUNTER TOP PULLED AWAY FROM WALL, DOES NOT HAVE A NON ABSORENT MATERIAL ON COUNTER TOP, LIVING ROOM CLOSET HAS OPEN AND EXPOSED WIRING AND ADDED SPLICED WIRING, EXTERIOR WALLS HAS HAD HOLES KNOCKED THROUGH THEM FOR ADDED PIPES, WIRING, NOT RESEALED,
ELECTRICAL METER SHOWS DOUBLING, FUSES BURNT, WIRING BURNT, ADDED SUB-PANEL FOR ADDED HOT WATER TANK, ADDITIONAL WIRING ADDED, HAS ADDED JUMPER WIRES TO BY PASS FUSES, JUMPERS SHOWING WHERE HAS OVER HEATED AND BURNT, COOLER WIRING SPLICED, ADDED CONVENIENCE OUTLET TO COOLER, COMPLETE ELECTRICAL SERVICE NEEDS UPGRADING.
NOTICE AND ORDER ISSUED.
01/08/2004 INSP - INITIAL CODE ENFORCMENT Approved VISITED SITE TALKED WITH RESIDENT JOHN KELLERSMAN WHO DID STATED HAD NO GS FOR APPROX 2 YEARS, USING SPACE HEATERS. METER GONE, RECONNECT PERMIT NEEDED, EVERY THING IN YARD- TRASH AND DEBRIS ALL RENTERS, MEGA TRASH; DEBRIS THROUGH OUT. CARPORT WORK AREA DETERIORATED ABOUT TO FALL, 13 VEHICLES ON SITE ALL NOT REGISTERED.
HOUSE SOUTH SIDE, EXPOSED WIRING-DEAD NOT CONNECTED, HAD EXTENSION CORD, HAS BEEN DISCONNTECTED, HAZARDOUS ELECTRICAL KITCHEN EXTENSION CORD WIRED SPLICED INTO POWER, GOING TO CONVENIENCE BOX, BOTH PLUG SOCKETS BEING OCCUPIED,, EXPOSED. POWER FROM LIGHT SWITCH GOING TO LIGHT FIXTURE DOES HAVE HOT AND WATER HOLES IN WALLS THROUGHOUT UNIT. DRY WALL NOT TAPED OR FINISHED, TUB AND SHOWER AREA, LACKING FRONT WALL, HAS WOOD ON WALL, HOLES NO SEALED, BATHROOM WINDOW DOES NOT OPEN ALSO WALL AND WINDOW SEPERATION SHOWS LIGHT TO EXTERIOR AT BOTTOM OF WINDOW, BATH SINK PLUGGED UP, ALL OF UNDERWEIGHT OPEN TO KITCHEN, DKITCHEN, DOOR JAMMED, BATH DETERIORATED, FURNACE DOES NOT OPERATE, DRYWALL MISSING, NO SMOKE DETECTORS, NORTH WEST BEDROOM HAS BROCKEN T-STAT, WINDOW OPENS, MISSING CRANK, HALL CEILING OPEN TO CRAWL SPACE, WALL HAS BEEN ERECTED TO SEPERATE LIVING ROOM TO MAKE SOUTH EAST BEDROOM, NO EGRESS BUNK BEDS, BEDROOM NORTH EAST BUNK BEDS, WINDOWS OPENS- MISSING CRANK DEBRIS EVERYWHERE SLIDING GLASS DOOR FRAME MISSING HAS APPROX 2" OPEN WILL NOT SEAL, BEHIND WOOD 4" T-14" HAD FURNACE GONE, DUST OPEN HOLE, SIDE ENTRY DOOR HAS NO WEATHER PROTECTION, ROACH INFESTED, SEWER CAP OPEN, RESIDENTS STATES BACKS UP EVERY OTHER DAY, GROUND IS WET, MAIN WATER SUPPLY SHUT OFF HANDLES MISSING, 30 GAL ELECTRICA WATER HEATER- NO COVERS, SPLICED WIRING EXPOSED, 60 AMP SERVICE, DOUBLE LUGGED, WIRES BURNT, FUSES JUMPED, CALLED INSP II RICK TO PROPERTY-BOARDER LINE SHUT DOWN
REFUSAL TO LET IN FROM RESIDENT, WILL TRY FRO ELECTRICIAN NEXT WEEK DOES NOT WANT TO INSTALL HEATER