Case: T03DV01146
Case Details
Entered Date:
11/26/2003
Applicant:
ELLIS MILDRED TR
Description:
COMPLAINT:MIN HOUSING-MANY ISSUES
Outstanding Inspections
Case Number: T03DV01146
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| EMERGENCY CALL OUT | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T03DV01146
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/14/2004 | INSP - INITIAL CODE ENFORCMENT | JHURD | Approved | 1/8/04, VISITED SITE, TOOK PICTURES, MET WITH MARTIN ROMERO ON SIGHT, UPON ARRIVING COULD SEE PROPERTY IS IN A STATE OF DETERIORATION AND DILAPIDATION, FENCING SURROUNDING PROPERTY IS MADE OF ALL DIFFERENT SORTS OF MATERIALS, RESIDENT JOHN KELLERSMAN CAME OUT AND WHILE TALKING TO JOHN I ASKED IF HE HAD ALL UTILITIES CONNECTED AND JOHN STATED NO THEY DO NOT HAVE NATURAL GAS SUPPLY CONNECTED, I ASKED HOW LONG THEY HAVE BEEN WITH OUT GAS JOHN STATED ABOUT 2 YEARS, METER GONE, WILL NEED RECONNECT PERMIT, AS WALKING ON TO PROPERTY COULD SEE MEGA TRASH AND DEBRIS EVERY WHERE, APPEARS TO HAVE ANY THING AND EVERY THING ON PROPERTY, TREE HAS BEEN BUILT ALSO, KIDS USE TREE HOUSE AS CLUB HOUSE, STATED NO ONE STAY'S IN TREE HOUSE, ALSO BUILT WORK AREA, ROOF ON WORK AREA LOOKS AS IF IT IS READY TO COLLASPE, BOWING DOWN WARD IN MIDDLE, NOT BUILT CORRECTLY, WILL NEED TO BE REMOVED, EXTERIOR SHOWS 13 VEHICLES ON SITE, NONE OF WHICE IS RUNNING OR CURRENTLY REGISTERED, SOUTH SIDE OF STRUCTURE HAS OPEN AND EXPOSED WIRING AT PORCH LIGHT FIXTURE, HAS EXTENSION CORD RUNNING FROM EAVE TO POWER STRIP, HAS EXTENSION CORD GOING TO HOME MADE WORK SHED, THERE ARE NUMEROUS AREAS THAT HAS EXPOSED WIRING, EXTENSION CORDS, POWER STRIP CONNECTORS, EXTRA CONVENIENCE OUTLETS INSTALLED, NO COVER PLATES, EXTERIOR WEST SIDE OF STRUCTURE HAS EXPOSED WIRING HANGING FROM EAVES, ELECTRICAL HOT WATER TANK HAS BEEN INSTALLED, NO PERMIT, HAZARDOUS CONNECTIONS, OPEN AND EXPOSED, FRONT OF HOT WATER TANK MISSING ELECTRICAL COVER PLATES, WIRES COMMING THROUGH WALLS FOR A 4 GANG CONVENIENCE OUTLET BOX TO WASHER, WALLS HAS HOLES KNOCK THROUGH NOT RESEALED, BOTTOM OF WALL ON WEST SIDE HAS APPOX. 1'x3' OPENING WHERE PART OF WALL IS MISSING, IN SAME ARTEA HAS OPEN SEWER LINE CAP MISSING, WEATHER PROTECTION MISSING AROUND DOORS, HAS APPOX. 6'X4' PIECE OF WOOD ON WAY IN HALL WAY WHERE A HEATER HAS BEEN REMOVED, SLIDING GLASS DOOR AT EAST END OF HALL WAY MISSING PART OF FRAME, DOOR DOES OPEN FOR EGRESS, BEDROOMS HAS CLOTHES AND DEBRIS SCATTERED ABOUT ON FLOOR, DRESSERS, BEDS, THROUGHOUT, WILL NEED TO BE CLEANED AND REARRANGED FOR PROPER EGRESS, ALL ROOMS BUT ONE HAS WINDOWS THAT OPERATE FOR EGRESS, THE ONE BEDROOM SOUTHEAST CORNER, THAT HAS BEEN CREATED BY MOVING AND OR TOTALLY REMOVING WALLS HAS NO EGRESS, AND ON SOUTH WALL HAS PLYWOOD WHICH HAS OPENINGS TO EXTERIOR, ALOT OF DEBRIS, COLTHING SCATTERED ABOUT, HALLWAY GOING NORTH AND SOUTH HAS OPENING UP INTO ATTIC (CRAWL SPACE, NOT SEALED, ALSO DRYWALL ON CEILING HAS NOT BEEN FINISHED NO TAPING OR SEALING OF JOINTS, HOLES IN WALLS THROUGH OUT, HEATER AT NORTH END OF HALLWAY NOT OPERABLE, BEDROOM ON NORTH EAST CORNER, WINDOWS OPERATE, HAS METAL SHEATING LAYING UP AGAINST WINDOWS CREATES EGRESS PROBLEM, BEDROOM CLOSET HAS COOLER CONTROLS IN STALLED, WILL NEED TO BE REWIRED PROPERLY, INTERIOR WALLS DETERIORATED AND SEPERATING, BATHROOM SINK CABINET VANITY HAS HOLES UNDERNEITH GOING ALL THE WAY THROUGH THE WALL INTO KITCHEN, BATH TUB, SHOWER AREA LACKS WALL PROTECTION, ALLOWING WATER TO ENTER INTO WALL AND DETERIORATE STRUCTURE, HAS ABSORBENT MATERIALS INSTALLED ON WALL, BATH TUB IS MISSING OVERFLOW CAP, BATHROOM WINDOW FRAME WHERE WINDOW SITS IN FRAME IS SEPERATING AND SEPERATING ALLOWING LIGHT, WATER AND ALL ELEMENTS TO ENTER FROM OUTSIDE, TO DETERIORATE STRUCTURE, ELECTRICAL SYSTEM ON INTERIOR, ROMEX RUNNING TO KITCHEN LIGHT FIXTURE, INSTALL ELECTRICAL BOXES, MOUNTED TO WALL NOT PROPERLY INSTALLED, USING MANY EXTENSION CORDS, AND ELECTRICAL POWER STRIPS, OPEN AND EXPOSED WIRING, KITCHEN COUNTER TOP PULLED AWAY FROM WALL, DOES NOT HAVE A NON ABSORENT MATERIAL ON COUNTER TOP, LIVING ROOM CLOSET HAS OPEN AND EXPOSED WIRING AND ADDED SPLICED WIRING, EXTERIOR WALLS HAS HAD HOLES KNOCKED THROUGH THEM FOR ADDED PIPES, WIRING, NOT RESEALED, ELECTRICAL METER SHOWS DOUBLING, FUSES BURNT, WIRING BURNT, ADDED SUB-PANEL FOR ADDED HOT WATER TANK, ADDITIONAL WIRING ADDED, HAS ADDED JUMPER WIRES TO BY PASS FUSES, JUMPERS SHOWING WHERE HAS OVER HEATED AND BURNT, COOLER WIRING SPLICED, ADDED CONVENIENCE OUTLET TO COOLER, COMPLETE ELECTRICAL SERVICE NEEDS UPGRADING. NOTICE AND ORDER ISSUED. |
| 09/03/2008 | INSP - FOLLOW UP CODE ENFORCE | JHURD | Approved | VISITED SITE, YARDS ALL CLEAN, NO TRASH OR DEBRIS, OR OVERGROWN VEGETATION / ELECT PERMIT T04EL00069 UPGRADE PERMITED AND FINALED / GAS PERMIT T04PL00927 FINALED / COMPLIANT |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T03DV01146
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
| Date | Name |
| 02/08/2006 | CONTACTED BY PHONE |
| 01/26/2004 | NOTICE OF VIOLATION ISSUED |
| 01/26/2004 | COURT ORDERED ABATEMENT |
| 09/03/2008 | VIOLATION CLOSED |
| 01/23/2004 |