Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
02/14/2005 INSP - INITIAL CODE ENFORCMENT Approved REVISITED SITE, TOOK PICTURES, FOUND UNIT TO STILL BE VACANT AND SECURED AT THIS TIME, TRIED TO TALK WITH NEIGHBOR DENNIS WHO STATED ON LAST VISIT THAT HE AND HIS WIFE ARE TRYING OR IN PROCESS OF BUYING HOUSE, COULD NOT ENTER DENNIS'S YARD
11/17/2003 INSP - INITIAL CODE ENFORCMENT Correction Required 11/17/03, VISITED SITE, TOOK PICTURES, MET WITH RESIDENT PAT AND HER SON JOE, PAT AND JOE STATED THAT THEY HAVE BEEN DOING MOST OF THE WORK ON THE HOUSE AND PAYING FOR IT OUT OF THEIR POCKET AND IS SUPPOSEDLY TAKING IT FROM RENT, SON IS THE ONE WHO REPAIRED ROOF LEAK, FOUND SEVERAL HOUSING ISSUES ON INTERIOR AND EXTERIOR,
DOUBLED KEYED DEAD BOLT ON SECURITY SCREEN DOOR, FRONT DOOR MISSING REQUIRED THRESHOLD AND DOOR SWEEP, CAN SEE LIGHT AT BOTTOM OF DOOR, LIVING ROOM MISSING CONVIENCE OUTLET COVER PLATES, HAZARDOUS ELECTRICAL, KITCHEN LIGHT FIXTURE HANGING FROM ELECTRICAL WIRES, AND USING EXTENSION CORD TO SUPPLY POWER TO LIGHT, KITCHEN CEILING MISSING DRYWALL FROM ROOF LEAK AND REST OF CEILING NOT FINISHED, NO COVERINGS, DRYWALL MISSING FROM UNDER KITCHEN CABINETS LEAVING HOLES, KITCHEN SINK LEAKING UNDER CABINET AT PIPES, KITCHEN DRAWER MISSING FACE PLATE, EXHAUST VENT OVER STOVE MISSING EXHAUST FAN MOTOR HAS ONLY A PIPE GOING THROUGH CEILING THROUGH ROOF LINE, KITCHEN CONVENIENCE OUTLET NOT GFCI PROTECTED, BATH ROOM CEILING NOT FINISHED FROM ROOF LEAK NO FINISH COVERINGS, BATHROOM LIGHT SWITCH MISSING COVER PLATE, CLOSET MISSING ACCESS COVER PANEL, WATER SUPPLY LINE IN CLOSET MISSING SHUT OFF HANDLE, BATHROOM CONVENIENCE OUTLET MISSING COVER PLATE AND NOT GFCI PROTECTED, 2ND BEDROOM (NORTH SIDE) MISSING DRYWALL FROM CEILING, ALSO MISSING WINDOW CRANKS, NORTH WALL WINDOWS DO NOT OPEN, EAST WALL WINDOWS MISSING WINDOW CRANK HANDLES, 2ND BEDROOM SMOKE DETECTOR BROKEN DOES NOT OPERATE, HAS HOLE IN CLOTHES CLOSET FROM PIPE, LIGHT FIXTURE HANGING FROM WALL IN HALLWAY, EXPOSED ELECTRICAL WIRING, HALLWAY CIELING NOT FINISHED NO FINISHED COVERINGS, BEDROOM (SOUTH SIDE) WINDOWS DO NOT OPERATE PROPERLY, WINDOW CRANKS BROKEN AND OR MISSING, FRONT FACIA BOARD HAS BEEN INSTALLED NOT WEATHER PROTECTED, NO PAINT, OR SEALANT, REAR PATIO PORCH HAS BEEN ADDED NO PERMIT ON FILE, NOT BUILT TO CODE USING 2"x4" SPANNING APPOX 10', 24" ON CENTERS USING 4X4 SUPPORT POST THESE ARE ALSO OVER SPANNED ALSO WILL NOT PAST PERMIT INSPECTION, ALSO WOOD IS RAW NO PROTECTION OR PROTECTIVE COATINGS, HOT WATER TANK FLUE PIPE DOES NOT MEET CODE TO SHORT DOES NOT GO THROUGH OR PASS ROOF LINE, NO PERMIT ON FILE, NEW ELECTRICAL SERVICE PANEL BOX HAS BEEN INSTALLED NOT ACTIVE AS OF YET, NO PERMIT ON FILE FOR THIS INSTALLATION, ACTIVE METER HAS EXPOSED WIRING, EXPOSED WIRES GOING TO ADDED CONVIENCE OUTLET, OUTLET NOT WEATHER PROTECTED, ALSO HAS ADDED FUSE BOX WITH 2 FUSES INSTALLED NO PERMITS ON FILE FOR EITHER OF THESE INSTALLATIONS, N.O TO FOLLOW