| 11/17/2003 | INSP - INITIAL CODE ENFORCMENT | JHURD | Approved | 11/17/03, VISITED SITE, TOOK PICTURES, MET WITH RESIDENT PAT AND HER SON JOE, PAT AND JOE STATED THAT THEY HAVE BEEN DOING MOST OF THE WORK ON THE HOUSE AND PAYING FOR IT OUT OF THEIR POCKET AND IS SUPPOSEDLY TAKING IT FROM RENT, SON IS THE ONE WHO REPAIRED ROOF LEAK, FOUND SEVERAL HOUSING ISSUES ON INTERIOR AND EXTERIOR, DOUBLED KEYED DEAD BOLT ON SECURITY SCREEN DOOR, FRONT DOOR MISSING REQUIRED THRESHOLD AND DOOR SWEEP, CAN SEE LIGHT AT BOTTOM OF DOOR, LIVING ROOM MISSING CONVIENCE OUTLET COVER PLATES, HAZARDOUS ELECTRICAL, KITCHEN LIGHT FIXTURE HANGING FROM ELECTRICAL WIRES, AND USING EXTENSION CORD TO SUPPLY POWER TO LIGHT, KITCHEN CEILING MISSING DRYWALL FROM ROOF LEAK AND REST OF CEILING NOT FINISHED, NO COVERINGS, DRYWALL MISSING FROM UNDER KITCHEN CABINETS LEAVING HOLES, KITCHEN SINK LEAKING UNDER CABINET AT PIPES, KITCHEN DRAWER MISSING FACE PLATE, EXHAUST VENT OVER STOVE MISSING EXHAUST FAN MOTOR HAS ONLY A PIPE GOING THROUGH CEILING THROUGH ROOF LINE, KITCHEN CONVENIENCE OUTLET NOT GFCI PROTECTED, BATH ROOM CEILING NOT FINISHED FROM ROOF LEAK NO FINISH COVERINGS, BATHROOM LIGHT SWITCH MISSING COVER PLATE, CLOSET MISSING ACCESS COVER PANEL, WATER SUPPLY LINE IN CLOSET MISSING SHUT OFF HANDLE, BATHROOM CONVENIENCE OUTLET MISSING COVER PLATE AND NOT GFCI PROTECTED, 2ND BEDROOM (NORTH SIDE) MISSING DRYWALL FROM CEILING, ALSO MISSING WINDOW CRANKS, NORTH WALL WINDOWS DO NOT OPEN, EAST WALL WINDOWS MISSING WINDOW CRANK HANDLES, 2ND BEDROOM SMOKE DETECTOR BROKEN DOES NOT OPERATE, HAS HOLE IN CLOTHES CLOSET FROM PIPE, LIGHT FIXTURE HANGING FROM WALL IN HALLWAY, EXPOSED ELECTRICAL WIRING, HALLWAY CIELING NOT FINISHED NO FINISHED COVERINGS, BEDROOM (SOUTH SIDE) WINDOWS DO NOT OPERATE PROPERLY, WINDOW CRANKS BROKEN AND OR MISSING, FRONT FACIA BOARD HAS BEEN INSTALLED NOT WEATHER PROTECTED, NO PAINT, OR SEALANT, REAR PATIO PORCH HAS BEEN ADDED NO PERMIT ON FILE, NOT BUILT TO CODE USING 2"x4" SPANNING APPOX 10', 24" ON CENTERS USING 4X4 SUPPORT POST THESE ARE ALSO OVER SPANNED ALSO WILL NOT PAST PERMIT INSPECTION, ALSO WOOD IS RAW NO PROTECTION OR PROTECTIVE COATINGS, HOT WATER TANK FLUE PIPE DOES NOT MEET CODE TO SHORT DOES NOT GO THROUGH OR PASS ROOF LINE, NO PERMIT ON FILE, NEW ELECTRICAL SERVICE PANEL BOX HAS BEEN INSTALLED NOT ACTIVE AS OF YET, NO PERMIT ON FILE FOR THIS INSTALLATION, ACTIVE METER HAS EXPOSED WIRING, EXPOSED WIRES GOING TO ADDED CONVIENCE OUTLET, OUTLET NOT WEATHER PROTECTED, ALSO HAS ADDED FUSE BOX WITH 2 FUSES INSTALLED NO PERMITS ON FILE FOR EITHER OF THESE INSTALLATIONS, N.O TO FOLLOW |
| 12/29/2004 | INSP - FOLLOW UP CODE ENFORCE | JHURD | Approved | (this goes along with previous 12-29-04 entry) NEIGHBOR TO DENNIS RYAN IS BUYING HOUSE, EXPECTED TO CLOSE WITH IN NEXT FEW WEEKS, AS TALKING WITH DENNIS HE IS AWARE THE CITY HAS OPEN CASE AND UNDERSTANDS IT WILL BECOME THEIR RESPONSIBILITY TO COME INTO COMPLIANCE, ALSO EXPLAINED TO DENNIS THAT THE 1ST THING THEY SHOULD DO AFTER CLOSING IS TO GO DOWN TO D.S.D. AND SECURE A COMBO PERMIT, THIS WILL COVER ALL ISSUES HE WILL NEED TO ADDRESS. GAVE DENNIS MY CARD WITH CONTACT #. DENNIS STATED HE WOULD KEEP ME IN THE LOOP AS TO WHAT IS GOING ON AND WHEN THEY CLOSE ON HOUSE. |
| 12/29/2004 | INSP - FOLLOW UP CODE ENFORCE | JHURD | Approved | 12/29/04, REVISITED SITE, FOUND STRUCTURE STILL VACANT AND SECURED AT THIS TIME, WHILE ON SITE NEIGHBOR TO WEST DENNIS RYAN CAME OVER TO SEE WHAT WAS HAPPENING, I EXPLAINED TO DENNIS WHAT I WAS DOING THERE, DENNIS AND HIS WIFE ARE IN PROCESS OF BUYING STRUCTURE, STATED SHOULD BE CLOSING ON HOUSE IN A COUPLE OF WEEKS, I EXPLAINED TO DENNIS THAT THE CITY HAS OPEN CASE ON STRUCTURE, HE IS AWARE AND STATED THAT HE DOES HAVE A COPY OF NOTICE AND ORDER. AS TALKING WITH DENNIS I EXPLAINED THAT WHEN HE CLOSES ON PROPERTY HE SHOULD GO DOWN TO D.S.D. AND SECURE A REPAIR/REMODEL COMBO PERMIT THIS WOULD COVER ALL HIS ISSUES AND WOULD ABATE MOST OF CITY'S ISSUES, HE AGREED. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T03DV00984
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
| Date | Name |
| 01/10/2007 | CONTACTED BY PHONE |
| 11/25/2003 | NOTICE OF VIOLATION ISSUED |
| 11/25/2003 | COURT ORDERED ABATEMENT |
| 06/12/2007 | VIOLATION CLOSED |
| 03/10/2005 | FAX: |