Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T03CM05891
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/20/2004 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
08/19/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 12'-16' GROUTED WITH OUT INSP. TOP OUT WESTEND LINTELS 16' OTHERS @ LINTELS. | |
08/17/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/PARTIAL-COLUMNS 1)GIRDS? STABILIZER REF 201 2)WOOD NAILS ON STEEL JOIST REF 209 (NOT ENOUGH SCREWS) 3)WALL BRASSES @ LENTALS 4)DECK NAILS OK WEST 1/2 OK TO DRY IN WEST 1/2 1035-PARTIAL-DRY PACK UNDER CELS? OK |
|
08/13/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :10'4" @ COLUMNS | |
08/12/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/09/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/ 1) OK TO TOP OUT MAIN BLDG WHEN SPEC INSPECTION CONFIRMS BOND BEAM IN SOUTH WALLS | |
08/06/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/ 1) 20'-8" N AND S CENTER AREA | |
08/04/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/ 1) PARTIAL TO LEDGER EAST 1/2 NORTH WALL | |
08/03/2004 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
08/02/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :NO FULL LIFTS READY | |
07/29/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/ 1) TOP WEST 1/2 NORTH WALL, TOP OVER W 18 X 40 AND 13'-8" MIDDLE OF NORTH WAY | |
07/28/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/ 1) 20' NORTH WALL | |
07/26/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :20'8" EAST 22'8" S.E. 16'8" EAST DEMISE 16' NW T.O.W. SW T.O.W. WEST REMOVE BOND BEAM PAPER OVER LINTEL COMPLETE VENTS TOP OF WALL OK TO GROUT |
|
07/23/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
07/21/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :TOP EAST END TO 60' OF SOUTH 16' & 12' INTERMEDIATE DEMISING WALLS TOP @ WEST ZIG ZAG TO TOP OF LENTIL WEST WALL |
|
07/14/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 12' EAST WALL, 16' @ SOUTH WALL, 8' INT WALLS | |
07/12/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*13' NORTH WALL. YOU NEED 50" TOP(?) SPLICE WHEN 2 BARS ARE IN SINGLE GROUT CELLS. YOU MAY NOT "PULL" STEEL THAT HAS BEEN APPROVED ALREADY IN ORDER TO GET 50"AT TOP OF A HIGHER GROUT LIFT. | |
07/08/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
07/06/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 8' SEST 1/2 FRONT. | |
07/02/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/ 1) 12' SOUTHWALL WEST 1/2 | |
06/30/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
06/28/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*PARTIAL APPROVAL | |
06/21/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/PARTIAL-8-10' CD LINES |