Permit: T03CM05865

Parcel: 129110230


Addresses:

1430 S NEW ST #01

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
06/01/2005 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :* 1) ALL CORRECTIONS HAVE BEEN MADE.
05/19/2005 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) SHALL PROVIDE A DBL FIXTURE FITTING LOCATED IN A VERTICAL POSITION. 2) RE TEST THE SYSTEM
05/18/2005 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*1) CANNOT LOCATE A HORIZONTAL VENT BELOW 6" OF THE FLOOD RIM LEVEL OF THE FIXTURE. 2) WASTE & VENT SYSTEM IS LEAKING CHECK ENTIRE SYSTEM. 3) MIN. TRAP ARM SIZE FOR LAVATORIES IS 1 1/2 AND C.O. SHALL BE LOCATED ONT HE 2" VERTICAL WASTE LINE. 4) INSTALL CLOSET RINGS. 5) NOTE: IF THE KITCHEN TRAP ARM 15 2" THEN THE TRAP SIZE SHALL BE 2" . 6) SHALL PROVIDE A MINOF 18" OF COPPER BEFORE CONNECTING TO PEX @ WATER HTR 05/17/05 HOT & COLD SUPPLY.