Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - PROGRESS
Permit Number - T03CM05851
Inspection Description - MECHANICAL - PROGRESS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/07/2004 | MECHANICAL - PROGRESS | Approved | IVRS - Inspection 0000*/ 1) DRYER VENT IN WALL OK. ABOVE PLATE, TERMINATE WITH 2"X4" INTO LARGER FLASHING OR TRANSITION 2½X4" INTO 4" CENTERLINE AND TERMINATE INTO 4" FLASH. 2) ALL SUPPLY/RETURN DUCT ABOVE CEILING GRID NEEDS TO BE WRAPPED WITH 3/4" DUCT WRAP WHEN LOCATED UNDER BLDG INSULATION. 3) AREA ABOVE CEILING GRID DOES NOT QUALIFY AS PLENIUM, R.A. ONLY PLENIUM RATED MATERIAL QUILIFIES |