Inspection History Details
Inspection Status: Partial Approval
Inspection History: FRAMING
Permit Number - T03CM05695
Inspection Description - FRAMING
Inspection Status - Partial Approval
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/22/2005 | FRAMING | Partial Approval | IVRS - Inspection :* | |
12/22/2005 | FRAMING | Approved | IVRS - Inspection :* | |
12/21/2005 | FRAMING | Partial Approval | IVRS - Inspection :* | |
12/20/2005 | FRAMING | Partial Approval | IVRS - Inspection :* | |
12/19/2005 | FRAMING | Partial Approval | IVRS - Inspection :* | |
12/16/2005 | FRAMING | Partial Approval | IVRS - Inspection :* SITE VISIT AND REVIEW OF INSP. REPORTS & SHEP DRAWINGS |
|
12/14/2005 | FRAMING | Partial Approval | 1. MET W/D.MANN ABOUT USE OF ABS DWV SYSTEM. HE HAS ASKED THAT CONTRACTOR SUBMIT PLANS USING ABS AS REVISION TO B. SLERRY COT CONCERN IS EXPOSED ABS SUBJECT TO MECHANICAL DAMAGE AND POSSIBLE VIOLATION OF CODE FOR DEVELOPED SMOKE (COMBUSTIBLE PIPE) IN A TYPE II A BUILDING 2. MET W/CONCORD SUPERINTENDENT "RUSS" AND INFORMED HIM OF D. MANN'S REQUEST CONCERNING DWV PIPE. WE ALSO WENT OVER FIRE SAFING REQUIREMENTS FOR ALL RATED ASSEMBLIES. 3. SUPERINTENDENT IS GOING TO GET COPIES OF ALL SPECIAL INSPECTIONS TO DATE. |
|
12/12/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :*MEETING WITH SUPERINTEDENT "JEFF" AND FIRE?? CONTRACTOR TO GO OVER FIRE SEPARATION AND FIRE RESISTIVE CONSTRUCTION AREA. BASEMENT LEVEL RESTROOMS HAVE AHD HARD LIDS INSTALLED BEFORE PROPER FIRE STOP WAS INSTALLED. CONTRACTOR IS AWARE THISI S CRITICAL CONSTRUCTION. | |
10/03/2005 | FRAMING | Partial Approval | IVRS - Inspection :* | |
08/04/2005 | FRAMING | Partial Approval | IVRS - Inspection :* | |
07/13/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 17 W LOUNGY FLR OK | |
06/16/2005 | FRAMING | Partial Approval | IVRS - Inspection :* STAGE, FOYER, M 27 W. 2ND FLR. | |
06/06/2005 | FRAMING | Partial Approval | IVRS - Inspection :* | |
05/19/2005 | FRAMING | Partial Approval | IVRS - Inspection :* BASEMENT MEN ? WO. STORAGE MAIN LEVEL BACKSTAGE WEST OK TO EFIS. OK TO COVER. | |
03/15/2005 | FRAMING | Partial Approval | IVRS - Inspection :* BALCONY SECOND FLR FRAME SHEET 53.0 DETAIL 254 & SK11 ROOF FRAMING PLAN S 3.4 DETAIL 1254 & SK13 | |
03/08/2005 | FRAMING | Partial Approval | IVRS - Inspection :* ROOF FRAMING BALCONY 2ND FL PARTIAL | |
02/11/2005 | FRAMING | Partial Approval | IVRS - Inspection :* PARTIAL 2 HR SEP. OK TO ROCK | |
02/04/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 2HR WALL 27W & 33 W BALCONY LEVEL |