Permit: T03CM05695

Parcel: 117120340


Addresses:

17 W CONGRESS ST


Inspection Status: Partial Approval

Inspection History: FRAMING

Permit Number - T03CM05695

Inspection Description - FRAMING

Inspection Status - Partial Approval

Date Description Inspector Results Comments
12/22/2005 FRAMING Partial Approval IVRS - Inspection :*
12/22/2005 FRAMING Approved IVRS - Inspection :*
12/21/2005 FRAMING Partial Approval IVRS - Inspection :*
12/20/2005 FRAMING Partial Approval IVRS - Inspection :*
12/19/2005 FRAMING Partial Approval IVRS - Inspection :*
12/16/2005 FRAMING Partial Approval IVRS - Inspection :*
SITE VISIT AND REVIEW OF INSP. REPORTS & SHEP DRAWINGS
12/14/2005 FRAMING Partial Approval 1. MET W/D.MANN ABOUT USE OF ABS DWV SYSTEM. HE HAS ASKED THAT CONTRACTOR SUBMIT PLANS USING ABS AS REVISION TO B. SLERRY COT CONCERN IS EXPOSED ABS SUBJECT TO MECHANICAL DAMAGE AND POSSIBLE VIOLATION OF CODE FOR DEVELOPED SMOKE (COMBUSTIBLE PIPE) IN A TYPE II A BUILDING
2. MET W/CONCORD SUPERINTENDENT "RUSS" AND INFORMED HIM OF D. MANN'S REQUEST CONCERNING DWV PIPE. WE ALSO WENT OVER FIRE SAFING REQUIREMENTS FOR ALL RATED ASSEMBLIES.
3. SUPERINTENDENT IS GOING TO GET COPIES OF ALL SPECIAL INSPECTIONS TO DATE.
12/12/2005 FRAMING Not ready for Inspection IVRS - Inspection :*MEETING WITH SUPERINTEDENT "JEFF" AND FIRE?? CONTRACTOR TO GO OVER FIRE SEPARATION AND FIRE RESISTIVE CONSTRUCTION AREA. BASEMENT LEVEL RESTROOMS HAVE AHD HARD LIDS INSTALLED BEFORE PROPER FIRE STOP WAS INSTALLED. CONTRACTOR IS AWARE THISI S CRITICAL CONSTRUCTION.
10/03/2005 FRAMING Partial Approval IVRS - Inspection :*
08/04/2005 FRAMING Partial Approval IVRS - Inspection :*
07/13/2005 FRAMING Partial Approval IVRS - Inspection :* 17 W LOUNGY FLR OK
06/16/2005 FRAMING Partial Approval IVRS - Inspection :* STAGE, FOYER, M 27 W. 2ND FLR.
06/06/2005 FRAMING Partial Approval IVRS - Inspection :*
05/19/2005 FRAMING Partial Approval IVRS - Inspection :* BASEMENT MEN ? WO. STORAGE MAIN LEVEL BACKSTAGE WEST OK TO EFIS. OK TO COVER.
03/15/2005 FRAMING Partial Approval IVRS - Inspection :* BALCONY SECOND FLR FRAME SHEET 53.0 DETAIL 254 & SK11 ROOF FRAMING PLAN S 3.4 DETAIL 1254 & SK13
03/08/2005 FRAMING Partial Approval IVRS - Inspection :* ROOF FRAMING BALCONY 2ND FL PARTIAL
02/11/2005 FRAMING Partial Approval IVRS - Inspection :* PARTIAL 2 HR SEP. OK TO ROCK
02/04/2005 FRAMING Partial Approval IVRS - Inspection :* 2HR WALL 27W & 33 W BALCONY LEVEL