Permit: T03CM05505

Parcel: 122070690


Addresses:

4441 E WAVERLY ST

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
07/12/2004 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*/ 1) OK ROUGH
07/08/2004 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) SUPPORT NM CABLE ON VERTICAL RUNS AS PER CODE AND HORIZONTAL RUNS ALSO 2) SUPPORT NM CABLE WITHIN 12" OF ALL BOXES 3) SUPPORT NM CABLE TO PANEL AND SEPERATE TO PREVENT BLDG AS PER CODE 4) CONDUCTOR OVERFILL AT BOXES 5) USE APPROVED PVC CONDUIT LISTED FOR ELECTRICAL 6) GROUND ALL METAL BOXES AND 4/0 BOXES 7) PROVIDE GROUND TAILS FOR SWITCHES 8) BATH FIXTURE MAY NEED A BOX 9) WHERE IS ROOF MOUNTED GFCI