Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM05445

Parcel: 136070060


Addresses:

9252 E 22ND ST

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
06/16/2004 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*/ ABOVE CEILING OK FOR SHEET ROCK.
06/15/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ H2O PIPING AIR TEST OK. EXCEPT YARD WTR. WASTE AND VENT WTR TEST THRU ROOF OK. WTR TEST 3" RAIN DRAIN AND OVERFLOW RAIN DRAIN SMALL BLD UPPER LEVEL OK. APPROVED WTR TEST FROM SMALL BLD 2-WAY C.O. THRU ROOF WASTE AND VENT OK.
06/14/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
06/14/2004 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
06/04/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ WTR TEST WASTE AND VENT THRU ROOF BIG BLD OK. H20 PRESSURE TEST 70 PSI FOR BIG BLD STUBBED THRU NORTH WEST CORNER AND CAPPED FOR SMALL BLD. OK. CHECK REFRIGERATOR ICE MAKERS FOR 1" AIR GAP OR PROVIDE 1 DBL CHECK ASSEMBLY PER APPLIANCE. DO NOT COVER BACKFLOW DEVICE WALL UNTIL AFTER ANOTHER INSP.