Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 02/23/2004 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/ CORRECTION MADE, REVISED CITY APPROVED DRAWING FOR WOK GREASE WASTE TURNED IN. TWO BACKFLOW CERTIFICATIONS TURNED IN. |
| 02/19/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) AGA OR CSA VALVE ON GAS AT WTR HTR. 2) ICE MACHINE REQUIRES APPROVED DRAINAGE MATERIAL FOR UPPER AND LOWER DRAINS SEPERATLY, WITH 1" AIR GAP AT FLOOR SINK. 3) WASHER MACHINE REQUIRES PROOF OF 1" AIR GAP FOR INLET H2O OR BACKFLOW PROTECTION REQUIRED FOR HOT H2O SUPPLY. [009] WASHER DRAIN TO BE GRAVITY DRAIN TO FLOOR SINK WITH 1" AIR GAP AND BE SECURED PROPERLY. 4) WILL REQUIRE CERTIFICATION OF ALL BACKFLOW DEVICES. 5) WILL REQUIRE APPROVED PLAN FOR WOK GREASE WASTE. |
| 02/18/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000* |