| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/06/2006 | PLUMBING - ROUGH, SOIL | Approved | ||
| 11/22/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*WATER TEST THRU 2-WAY CLEANOUT TO APP.15' FROM ROAD AT NORTH END 4" ABS BUILIDING SEWER OK | |
| 11/21/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999*PROVIDE SLEEVES ON PIPING FOR WATER & SEWER GOING UNDER STORM DRAINAGE MAKING CONTACT. |
|
| 11/02/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*REQUIRE 2% GRADE FOR 4" UNDERSLAB OR PROVIDE STAMPED LETTER FROM ARCHITECT ALLOWING 1 % UNDERGROUND FOR RESTROOM OK OK TO COVER WATER TEST ONE RISER TO TEN FEET. 4" MAIN OK TO COVER SUBJ TO ARCHITECT APPROVAL OF 1 % CONTRACTOR TO USE LEAN FILL AROUND PIPE |
|
| 10/27/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999*INSTALL PIPING PER APPROVED PLAN PROVIDE GOOD SHADING MATERIAL FOR PIPING HAVE ALL PIPING EXPOSED. |