Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03CM04472

Parcel: 14027041A


Addresses:

6151 S TUCSON BL


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T03CM04472

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
11/06/2006 PLUMBING - ROUGH, SOIL Approved
11/22/2005 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*WATER TEST THRU 2-WAY CLEANOUT TO APP.15' FROM ROAD AT NORTH END 4" ABS BUILIDING SEWER OK
11/21/2005 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*PROVIDE SLEEVES ON PIPING FOR WATER & SEWER GOING UNDER STORM DRAINAGE MAKING CONTACT.
11/02/2005 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*REQUIRE 2% GRADE FOR 4" UNDERSLAB OR PROVIDE STAMPED LETTER FROM ARCHITECT ALLOWING 1 %
UNDERGROUND FOR RESTROOM OK OK TO COVER WATER TEST ONE RISER TO TEN FEET.
4" MAIN OK TO COVER SUBJ TO ARCHITECT APPROVAL OF 1 %
CONTRACTOR TO USE LEAN FILL AROUND PIPE
10/27/2005 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*INSTALL PIPING PER APPROVED PLAN
PROVIDE GOOD SHADING MATERIAL FOR PIPING
HAVE ALL PIPING EXPOSED.