Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 12/30/2003 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 12/26/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) MUST STRAP AND SECURE GAS LINE UNDER PIZZA OVEN. 2) MUST PROVIDE A BACKFLOW PREVENTOR FOR COFFEE MACHINE, TEA DISPENSER AND ICE MAKER. TESTED AND CERTIFIED. 3) TRIPLE COMPT SINK IS DOUBLE TRAPPED AND REQUIRES A FLOW CONTROL VENT TO BE 6" ABOVE FLOOD RIM LEVEL 4) trap arm has offset for triple compt sink. |
| 12/09/2003 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000* |