Permit: T03CM02796

Parcel: 11628001E

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
08/05/2005 PLUMBING - INTERMEDIATE Approved
11/03/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/1)HAD MEETINGS WITH PLBG. CONTRACTOR FOR TEMP C 0F O. REQUREMENTS
11/01/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/1)CLOSET FLANGES ARE OK IN BLDG. D LEVEL 3, 4 & 5 2)OK TO SET WATER CLOSETS
10/21/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
10/19/2004 PLUMBING - INTERMEDIATE Cancelled IVRS - AP canceled
10/18/2004 PLUMBING - INTERMEDIATE Cancelled IVRS - AP canceled
10/12/2004 PLUMBING - INTERMEDIATE Cancelled IVRS - AP canceled
10/11/2004 PLUMBING - INTERMEDIATE Cancelled IVRS - AP canceled
10/08/2004 PLUMBING - INTERMEDIATE Cancelled IVRS - AP canceled
10/06/2004 PLUMBING - INTERMEDIATE Cancelled IVRS - AP canceled
10/05/2004 PLUMBING - INTERMEDIATE Partial Approval 1)CLOSET FLANGES ARE OK IN BLDG. 3 LEVEL P-1 AND LEVEL 1 AND BLDG. A B C LEVEL 4 ARE OK. 2)SHOWER DIVERTOR VALVES HAVE BEEN INSTALLED IN BLDG. G LEVEL P-1 RM #B231 & #B238 ARE OK 3)GAS PRESSURE TEST IS OK FOR BLDG. D LEVEL 7 MECH, RM #M903 4)OVERHEAD WATER DISTRIBUTION IS OK FOR BLDG 7 MECH RM #M901 & M903
10/02/2004 PLUMBING - INTERMEDIATE Cancelled IVRS - AP canceled
09/30/2004 PLUMBING - INTERMEDIATE Partial Approval 1) TUB WASTE & OVERFLOW WATER TEST IS OK FOR ENTIRE FLOOR LEVEL BLDG H AS NOTED ON PLAN. 2) BLDG A, B, C, LEVEL 3 CLOSET FLANGES ARE OK. 3) HOT & COLD DOMESTIC WATER LINE FOR LAUNDRY ROOM H-P-I IS OK. 4) BLDG G LEVEL P-1 RESTROOMS P-243 7 P-245 SOIL WATER TEST IS OK.
09/30/2004 PLUMBING - INTERMEDIATE Cancelled IVRS - AP canceled
09/28/2004 PLUMBING - INTERMEDIATE Cancelled IVRS - AP canceled
09/28/2004 PLUMBING - INTERMEDIATE Partial Approval 1) OVERHEAD WATER DISTRIBUTION DOMESTIC HOT & COLD AND RECIRCULATION LINES. AIR PRESSURE TEST IS OK ON BLDG H LEVEL P-1 SPECIALLY KITCHEN AREA ENTIRE SYSTEM. 2) AIR PRESSURE TEST FOR GAS SYSTEM IN BLDG D LEVEL 7 MECH. RM WEST RM #901. 3) AIR PRESSURE TEST & WATER TEST FOR OVERHEAD WATER DISTRIBUTION MECH RM BLDG D LEVEL 7 RM #901 IS OK. 4) TRAP ?? & DOMESTIC COLD WATER FOR BLDG G LEVEL 1& P/IS OK
09/27/2004 PLUMBING - INTERMEDIATE Cancelled IVRS - AP canceled
09/23/2004 PLUMBING - INTERMEDIATE Cancelled IVRS - AP canceled
09/18/2004 PLUMBING - INTERMEDIATE Cancelled IVRS - AP canceled
09/17/2004 PLUMBING - INTERMEDIATE Partial Approval 1) SOIL WATER TEST IS OK FOR OVERHEAD VENTS IN BLDG H LEVEL P-1 BANQUET KITCHEN AND LAUNDRY AREA AS NOTED ON PLAN
09/16/2004 PLUMBING - INTERMEDIATE Cancelled IVRS - AP canceled
09/15/2004 PLUMBING - INTERMEDIATE Partial Approval 1) HOT & COLD WATER DISTRIBUTION IS OK FOR SHOWER STALLS IN BLDG G LEVEL P-2 AS NOTED ON PLANS AIR PRESSURE TEST IS OK. 2) SOIL WATER TEST FOR OVERHEAD VENT AND REVENTS IN BLDG H. LEVEL P-1 BANQUET KITCHEN AREA IS OK. NOTE: SMALL RED LINE DRAWING SHOWING REVENTS ABOVE CEILINGS. 3) AIR PRESSURE TEST FOR HOT & COLD DOMESTIC WATER IN BLDG G LEVEL 3 & 4 RM # 5222, 5224, 6217, 6218, 6219, 6220, 6221, 6222, 6223, 6224, AND VENDING RM'S AS NOTED ON PLAN.
09/14/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
09/14/2004 PLUMBING - INTERMEDIATE Cancelled IVRS - AP canceled
09/13/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :* 1) AIR PRESSURE TEST IS OK FOR HOT & COLD WATER DISTRIBUTION IN BLDG G LEVEL 4 ENTIRE FLOOR INCLUDING ?NDINS AS NOTED ON PLAN. 2) AIR PRESSURE TEST IS OK FOR BLDG G LEVEL 4 RM # 6201, 6202,6203, 6204,6205, 6206, 6207, 6208, 6209, 6210, 6211, 6212, 6213, 6214, 6215, 6216, AS NOTED ON PLAN
09/10/2004 PLUMBING - INTERMEDIATE Partial Approval 1) AIR PRESSURE TEST IS OK FOR HOT & COLD DOMESTIC WATER IN BLDG C LEVEL #3 ROM # 5201, 5202, 5203, 5204, 5205, 5206, 5207,5208, 5209,5210, 5211, 5212, 5213, 5214, 5215, 5216, 5217, 5218, 5219, 5220, 5221, 5223, AS NOTED ON PLAN
09/09/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/1)SOIL WATER TEST IS OK FOR DWV IN BLDG H LEVEL 2 RM #4241,4243,4245,4247
2)6" RW. AND 3" VENT FOR BLDG GH KNUCKLE LEVEL 2,3 & R WATER TEST OK
3)OVERHEAD WATER DISTRIBUTION HOT & COLD AIR PRESSURE TEST IS OK FOR BANQUET KITCHEN AS NOTED ON PLAN
09/07/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/1)CLOSET FLANGES ARE OK FOR BLDG A,B &C LEVEL 2
2)0" RWL BLDG. H LEVEL 2,3 &4 WATER TEST IS OK
3)TUB WASTE & OVERFLOW WATER TEST IS OK FOR BLDG G LEVEL 4 RM #6201,6202, 6203, 6204, 6205, 6206, 6208, 6209, 6210, 6211, 6212,6214, 6215, 6216, 6217, 6218, 6219, 6220, 6221, 6223, AS NOTED ON PLAN
4)SOIL WATER TEST IS OK FOR BLDG H LEVEL 2, 3, &4 RM# 4237, 4239, 4238, 4240, 4242, 4244, 4246, 4248, 5237, 5238, 5239, 5240, 5241, 5242, 5243, 5244, 5245, 5246, 5247, 5248, 6237, 6238, 6239, 6240, 6241, 6242, 6243, 6244, 6245, 6246, 6247, 6248, AS NOTED ON PLAN
09/03/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
09/02/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection AREA B LEVEL P2
DOMESTIC WATER TO 8 EACH DIVERTERS @ SHOWERS P178 & P133 ALSO 1" TO MECH 107 & STEAM ROOM AND MECH 105 W/STEAM ROOM PRESSURE TEST @ 98PSI OK
2"DWV AREA P2-G FROM LAUNDRY FLOOR SINK ON P1 OVER TO B112 SINK IN DISPENSARY (REDLINED PLANS)
09/01/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection ::AREA G LEVEL 2 DOMESTIC HOT COLD AND RECIRCULATION OK-AIR TEST 0O
AREA H LEVEL 1 SOIL-WASTE-VENT (DWV)OK FOR EAST 1/2 RWL OK EAST 1/2
LEVEL 2 DWV OK ENTIRE FLOOR RWL OK EAST 1/2
LEVEL 3 DWV OK WEST 1/2
LEVEL 4 DWV OK WEST 1/2
PLANS WERE NOT HIGHLIGHTED AT THIS TIME
08/31/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) GAS PRESSURE TEST OF ALL GAS DROPS FROM CEILING STUB UP TO ALL GAS DROPS IN WALLS ONLY FOR BLDG H BANQUET KITCHEN 2) OK FOR DRY WALL IN THESE AREAS 3) TUB WASTE AND OVERFLOW WATER TEST IS OK FOR BLDG G LEVEL 2 THE ENTIRE FLOOR. ROOM # 4201 THRU 4224 4) BLDG D, E KNUCKLE DOMESTIC COLD AND HOT AND RECIRCULATION LINES ARE OK AIR PRESSURE TEST IS OK
08/27/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/P-AP
1)SOIL WATER TEST FOR WASTE & VENT SYSTEM BLDG H LEVEL 2 RM#4225, 4226, 4227, 4228, 4229, 4230, 4231, 4232, 4233, 4234, 4235, 4236, AS NOTED ON PLAN
2)2-6" R.W.L. FROM LEVEL 2 BLDS. H TO LEVEL 1 WEST SIDE ONLY IS OK
3)RWL IN KNUCKLE AREA TO ROUT? BETWEEN BLDG. G & H ARE OK
08/26/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) SOIL WATER TEST IS OK FOR BLDG H LEVEL P-1 BANQUET KITCHEN AREA ALL WASTE AND VENT SYSTEM WITHIN WALLS AND ABOVE CEILING 2) WATER DISTRIBUTION WITHIN WALLS ONLY AIR PRESSURE TEST IS OK
08/25/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) SOIL WATER TEST IS OK FOR BLDG G LEVEL 3 AND 4 RM# 5210, 5212, 5207, 5211, 5213, 5216, 5214, 5215, 5218, 5217, 5219, 5220, 5221, 5223, 6210, 6212, 6209, 6211, 6213, 6214, 6215, 6218, 6217, 6219, 6220, 6221, 6223, 6216, 6208 AND 6206 2) TUB WASTE AND OVERFLOW WATER TEST IS OK FOR BLDG D RM# 4057, 4058, 4081 AND 5081 ARE OK AS NOTED ON PLAN 3) GAS PRESSURE TEST IS OK FOR GAS SYSTEM THRU BLDG D FROM LEVEL 1 ALL THE WAY UP TO EQUIPMENT ROOM AS NOTED ON PLAN IN ORANGE 4) GAS LINE FOR FIREPLACES IN LEVEL 5 AND 6 ARE OK 5) AIR PRESSURE TEST OK FOR BLDG C LEVEL 4 ENTIRE FLOOR TO KNUCKLE
08/24/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) AIR PRESSURE TEST FOR HOT AND COLD DOMESTIC IS OK RM# P-123 JUICE BAR 2) WATER TEST FOR BLDG G LEVEL 2, 3, 4 AND 5 TO ROOF IS OK AS NOTED ON PLAN FOR RWL 6" 3) AIR PRESSURE TEST IS OK FOR HOT AND COLD DOMESTIC WATER FOR LAUNDRY RM# B-403 LEVEL 2 KNUCKLE AREA AS NOTED ON PLAN 4) SOIL WATER TEST IS OK FOR BLDG AT RM# 5101, 5102, 5103, 5104, 6201, 6202. 6203 AND 6204 TO ROOF AS NOTED ON PLAN 5) TUB WASTE AND OVERFLOW WATER TEST IS OK FOR BLDG D LEVEL 4 AND 5 RM# 5058, 6058, 7058 AND 7084 AS NOTED ON PLAN
08/23/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) TUB WASTE AND OVER FLOWR WATER TEST IF OK FOR BLDG D RM# 4084, 5059, 5084, 6059, 6081, 6084, 7059 AND 7081 AS NOTED ON PLAN 2) SOIL WATER TEST FOR BLDG G RM# 4231, 4215, 4217, 4219, 4221 AND 4223 AS NOTED ON PLAN 3) AFTER HOURS INSPECTIONS CHARGED TO APA ACCOUNT MINIMUM 3 HRS.
08/20/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :SOIL WATER TEST IS OK FOR LEVE 2 ROOM 4201 - 12 & 4514, 4216, 4218, 4220, 4222, 4224.
TUB WASTE & OVERFLOW WATER TEST IS OK FOR ROOM #8058, 8084, 8081 bLDS D LEVEL 6
AIR PRESSURE TEST IS OK FOR BLDG D LEVEL 5, 6 ROOM 8058, 7058 AS NOTED ON THE PLAN
08/19/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) SOIL WATER TEST IS OK FOR BLD H LEVEL P-1 2 WASTE LINE STUBBED BELOW FLOOR ONLY 2) AIR PRESSURE TEST FOR HOT AND COLD WATER DISTRIBUTION FOR BLDG A KNUCKLE AREA AS NOTED ON PLAN
08/18/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/2010 UNDERGROUND-PARTIAL OK
1)100' PVC FROM FOOL EQUIP ROOM SOUTH-
1-2" PVC, 1-1 1/4 PVC, 1-1" PVC OK TO COVER POOL AREA
08/17/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/PARTIAL
1)SOIL WATER TEST IS OK FOR AREA DRAIN IN BLDG. H LEVEL 1 AS NOTED ON PLAN
08/17/2004 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :SHALL REMOVE ALL DRYWALL AND INSULATION PRIOR TO INSPECTION
DRYWALL HAS BEEN INSTALLED PRIOR TO INSPECTION
08/16/2004 PLUMBING - INTERMEDIATE Partial Approval 1) THESE RESULTS SHOULD HAVE BEEN ENTERED BY INSPECTOR ON 8/12/04: 1) SOIL WATER TEST IS OK FOR 4" RWL BLDG D, E KNUCKLE AREA LEVEL 5 AND 6 AS NOTED ON PLAN 2) TUB WASTE AND OVERFLOW TEST IS OK FOR BLDG D, C KNUCKLE AREA ROOM # 6058 3) SOIL WATER IS OK FOR BLDG G LEVEL P-1 AND P-2 MENS AND WOMENS RESTROOM AND ROOM #'S B238, B231 AS NOTED ON PLAN
08/13/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) THESE RESULTS SHOULD HAVE BEEN ENTERED BY INSPECTOR ON 8/12/04: 1) SOIL WATER TEST IS OK FOR BLDG. P KNUCKLE AREA ROOM # 8081, 8084, V802 2) 6" RWL IS OK FOR BLDG D LEVEL 5, 6 AND TO ROOF 3) SOIL WATER TEST IS OK FOR BLDG D LEVEL 5 ROOM # 7081, 7084, P-702 AS NOTED ON PLAN
08/11/2004 PLUMBING - INTERMEDIATE Partial Approval THIS INSPECTION SHOULD HAVE BEEN ENTERED IN ON 8/4/04. 1) AIR PRESSURE TEST FOR RECIRCULATION LINE FROM MEZZENEEN EQUIPMENT ROOM TO BLDG G 2) SOIL WATER TEST IS OK FOR BLDG G-P-2 FOR WOMENS RESTROOM LAVATORYS ROOM B 231 AND MENS LAVATORYS AND URINALS ROOM B-238 AND MENS LOCKER ROOM B-239 FLOOR DRAINS 3) SOIL WATER TEST OK FOR RESTROOM P176 BLDG G P2 4) SOIL WATER TEST IS OK FOR BLDG D LEVEL P1 V-202 5) 6" RWL OK FROM LEVEL P1, 1 AND 2 6) SOIL WATER TEST IS OK FOR BLDG O ROOM 4081, 4082, 4084 TUB WASTE AND OVERFLOW TEST OK FOR ROOM 4082 7) SOIL WATER TEST OK FOR BLDG D LEVEL 3 ROOM 5081, 5084
08/11/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) SOIL WATER TEST IS OK FOR WASTE AND VENT SYSTEM IN BLDG B,C AND D KNUCKLE AREA ROOM # 4057, 4058 AND IN LAUNDRY B-403 LEVEL 2 AND 3 ROOM # 5059 AND 5058 2) SOIL WATER TEST IS OK FOR AREA DRAINS 3" IN BLDG G-P-2 + P-1 3) SOIL WATER TEST IS OK FOR BLDG G LEVEL P-1 WOMENS LOCKER ROOM NUMBERS B-234 FLOOR DRAINS AND HORIZONTAL VENTS 4) SOIL WATER TEST IS OK FOR BLDG G LEVEL P-2 + P-1 FOR 6" RWL AT COLUMN AA TO BB2 AND GRID #10 TO 7.1 AS NOTED ON PLAN 5) SOIL WATER TEST TEST OK FOR 6" RWL IN BLDG J LEVEL P-1 AND 1 AS NOTED ON PLAN
08/10/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
08/09/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) TUB WASTE AND OVERFLOW WATER TEST IS OK FOR BLDG D LEVEL 5 AND 5 ROOM NUMBERS 7061, 7073, 7080, 7078. 7066, 7064, 2) TUB WASTE AND OVERFLOW WATER TEST IS OK FOR BLDG D LEVEL 4 FOR ROOM NUMBERS 6082, 6077, AS NOTED ON PLAN
08/07/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) TUB WASTE AND OVERFLOW WATER TEST IS OK FOR BLDG D LEVEL 6 ROOM NUMBERS 8066, 8060, 8067, AS NOTED ON PLAN 2) OVERHEAD WATER DISTRIBUTION IS OK AIR PRESSURE IS OK FOR BLDG D LEVEL 5 AND 6 ROOM NUMBERS 7061, 7077, 7066, 8061, 8077, 8076, 8074, 8066, 8064 AND 8060 3) SOIL WATER TEST IS OK FOR BLDG G LEVEL P-2 AND P-1 AS NOTED ON PLAN 4) SOIL WATER TEST FOR 6" GREASE WASTE APPROX. 85' FROM TWO WAY CLEANOUT TO INTERCEPTOR LOCATION 5) AFTER HRS INSPECTION 2 HRS CHARGED TO ATA ACCOUNT
08/05/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
08/04/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) SOIL WATER TEST IS OK FOR WASTE AND VENT SYSTEM IN BLDG D LEVEL 6 AS NOTED ON PLAN 2) 6" R.W.L. WATER TEST IS COMPLETE TO ROOF FOR BLDG D ALL LEVELS
08/03/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) LEVEL P-1 AND LEVEL WING D VENDING ROOM BLDG D NORTH FLOOR SINKS AND VENTS TO CEILING HEIGHT OF LEVEL. WATER TEST OK. BLDG LEVEL P-1 RECEPTION PUBLIC RESTROOM WASTE AND VENT TO 10' ABOVE FINISH FLOOR WATER TEST. 6" RAIN LOADER WATER TEST BLDG G P1 TO 1" ABOVE FINISHED FLOOR OK. BLDG LEVEL P1 RESTROOM P231 WASTE AND VENT TO 10' ABOVE FINISH FLOOR OK (3) FLOOR SINKS DRAINAGE CAFETERIA 242 FROM FINISH FLOOR DOWN TO P2 AND PIPING MARKED ON P2.21 A IN ORANGE AND INITALLED. 4" RISER BLDG LEVEL P2 FOR 3 FLOOR SINKS
07/30/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) SOIL WATER TEST IS OK FOR 6" RWL BLDG. D LEVEL 3 AND 4 NORTH ONLY 2) SOIL WATER TEST IS OK FOR WASTE AND VENT SYSTEM IN BLDG D LEVEL 5 ENTIRE FLOOR AS NOTED ON PLAN 3) TUB WASTE AND WATER OVERFLOW TEST OK FOR BLDG. D LEVEL 5 ROOMS # 7061, 7065, 7067, 7069, 7071, 7074, 7075, 7076, 7077 ONLY. 4) OVERHEAD WATER DISTRIBUTION IS OK FOR BLDG. G LEVEL P-2 AIR TEST IS OK AS NOTED ON PLAN
07/29/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*(1) SOIL WATER TEST IS OK FOR BLDG. D LEVEL 4 ENTIRE FLOOR AS NOTED ON PLAN. (2) TUB OVERFLOW WATER TEST IS OK FOR BLDG. D LEVEL 4 ROOM 6060, 6061, 6063, 6064, 6065, 6066, 6067, 6068, 6069, 6070, 6071, 6073, 6074, 6075, 6076, 6078, AND 6079 AS NOTED ON PLAN. (3) OVERHEAD WATER DISTRIBUTION IS OK FOR BLDG. D LEVEL 3 ROOM 5073, 5074, 5075, 5076, 5077, 5078, 5079, 5080, LEVEL 4 6073, 6074, 6075, 6076, 6077, 6078, 6-79, 6080, LEVEL 5 7073, 7074, 7075, AND 7076 AS NOTED ON PLAN.
07/28/2004 PLUMBING - INTERMEDIATE Partial Approval 1) AIR PRESSURE TEST FOR HOT & COLD WATER DISTRIBUTION IS OK FOR BUILDING D LEVEL 3 & 4 ENTIRE FLOOR AND LEVEL 5 ROOM #7062,7064,7065,7067,7069,7071 ONLY
2. CLOSET FLANGES ARE OK IN BLDG A LEVEL P-1.
07/27/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) WASTE AND OVERFLOW WATER TEST IS OK FOR BLDG E LEVEL 5 ENTIRE FLOOR IS OK AS NOTED ON PLAN 2) 6" RWL FOR BLDG E LEVEL 3, 4 AND 5 ARE OK
07/27/2004 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) NOT READY FOR INSPECTION
07/23/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
07/22/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*/ 1) NOT READY FOR INSPECTION
07/22/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :CLOSET FLANGES ARE OK IN BLDG B & C LEVEL P-1 EXCEPT 1 ROOM
SOIC WATER TEST OK FOR BLDG I BETWEEN KK & QQ AND 24-1 AND 25
07/20/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) SOIL WATER TEST IS OK FOR WASTE AND VENT SYSTEM FOR BLDG E LEVEL 3 TUB WASTE AND OVERFLOWS OK 2) 6" NORTH SIDE RWL FROM LEVEL 3 BLDG E TO LEVEL P-1 IS OK 3) VENT FOR BS1 ALL THE WAY TO ROOF
07/19/2004 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) WASTE AND VENT SYSTEM WOULD NOT PASS TEST 2) 6" RWL NO ABS PLUBS ALLOWED ON NO HUB MATERIAL 3) AFTER HRS INSPECTION ON ATA ACCOUNT 2 HR MINIMUM
07/19/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) SOIL WATER TEST IS OK FOR BLDG E LEVEL 1 ENTIRE FLOOR IS COMPLETE 2) SOIL WATER TEST FOR 6" RWL BLDG A AND B CORNER IS OK 3) SOIL WATER TEST IS OK FOR BLDG E LEVEL 2 AS NOTED ON PLAN 4) SOIL WATER TEST IS OK FOR WASTE AND VENT SYSTEM IN BLDG E LEVEL 3 ROOM #5103, 5101, 5095, 5093, 5096, 5094, 5092, 5096, 5087, 5085, LESS TUB TEST AS NOTED ON PLAN
07/14/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) SOIL WTR TEST IS OK FOR 6" RWL IN BLDG E LEVEL P-1 AS NOTED ON PLAN. 2) SOIL WTR TEST OK FOR BLDG E LEVEL 2 ROOMS 4097, 4098, 4099, 4100, 4102, 4104.
07/13/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) WATER TEST VETN MENS RESTROOM P-267 OK
07/12/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) BLDG E LEVEL 2 4089, 4091, WASTE AND VENT WATER TEST OK 2) BLDG J LEVEL P1 WASTE AND VENT WATER TEST RESTROOM WOMEN P264 OK 3) H20 PIPING 100 PSI AIR TEST WOMENS P-264, MUN SP 267 TO BE MARKED ON PLAN
07/10/2004 PLUMBING - INTERMEDIATE Partial Approval 1) SOIL WATER TEST IS OK FOR BLDG E LEVEL P-1 AND LEVEL 1 ROOM # 2104. 2102, 21010, 2098, 2096, 2094, 2092, 2090, 2088, 2086, 3086, 3088, 3090, 3092, 3094, 3096, 3098, 3100, 3102 AND 3104 AS NOTED ON PLAN 2) THIS INSPECTION ON AFTER HRS ATA ACCOUNT
07/09/2004 PLUMBING - INTERMEDIATE Not ready for Inspection 1) NOT READY FOR INSPECTION
07/08/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) SOIL WATER TEST IS OK FOR BLDG D LEVEL 3 ROOM 50714, 5076, 5078 AND 5080 AS NOTED ON PLAN 2) TUB WASTE AND OVERFLOWS OK IN THESE ROOMS
07/07/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) SOIL WATER TEST IS OK FOR 4" SANITARY AND 6" RWL FOR BLDG D LEVEL 3 WEST SIDE AS NOTED ON PLAN 2) 4" SANITARY WASTE FOR BLDG D LEVEL 3 ROOM #5061, 5063, 5065, 5067, 5069 AND 5071
07/01/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ OVERHEAD WTR DISTRIBUTION IS OK AIR PRESSRE TEST OF HOT AND COLD SYSTEM 100 LBS OK. 2) OK FOR INSULATION.3) THIS INSP IS FOR BLDG 'E' LEVEL P-1, 1-5 AS NOTED ON PLAN.
06/30/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) OVERHEAD WTR DISTRIBUTION OK. AIR TEST 100 LBS OK. 2) OK FOR INSULATION OF HOT WTR SYSTEM.
06/29/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) SOIL WTR TEST IS OK FOR 6" RWL BETWEEN GRID 22.5 AND 22.6 AND BETWEEN COLUMN 40 AND 43 AS NOTED ON PLAN. 2) SOIL WTR TEST IS OK WASTE AND VENT SYSTEM FOR BLDG 'D' LEVEL 3 ROOM 5073, 5075, 5077, 5079 ONLY AS NOTED PLAN.
06/25/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) SOIL WTR TEST FOR VENTS OVERHEAD IN BLDG 'D' LEVEL P-1 IS COMPLETE AS NOTED ON PLAN. 2) SOIL WTR TEST FOR WASTE AND VENT SYSTEM IN BLDG 'D' LEVEL 1 MENS AND WOMENS RESTROOM ROOM P-307, P-308 AS NOTED ON PLAN.
06/21/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ SOIL WTR TEST IS OK FOR BLDG 'D' LEVEL P-1 WASTE AND VENT SYSTEM BETWEEN GRID # 22.6 TO 22.8 AND BETWEEN COLUMN 40 TO COLUMN 42 AS NOTED ON PLAN.
06/17/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) SOIL WTR TEST FOR 6" AND 4" RWL FOR BLDG 'D' LEVEL P-1 UP 10' - LEVEL 1 AS NOTED ON PLAN. 2) WASTEA AND VENT SYSTEM WTR TEST FOR WTR CLOSETS AND LAV. BATTERY FOR BLDG 'D' LEVEL P-1 R00M 213 AND LAV BATTERY ONLY IN ROOM 205, 207,. NOTE: WTR CLOSET AND URINAL BATTERY. REVENT IS UNDERSIZED. 3) 2" MEDIUM PRESSURE GAS AIR TEST IS OK FOR BLDG H & I AS NOTED ON PLAN. 4) SOIL WTR TEST FOR WASTE AND VENT SYSTEM IN BLDG H LEVEL P-1 MENS AND WOMENS PUBLIC RESTROOMS AS NOTED ON PLAN. 5) 4" OVERHEAD 140o, 165o DOMESTIC HOT WTR BLDG 'H' 'I' AND 'J' LEVEL P-1 AS NOTED ON PLAN COMPLETED FROM BOILER RM TO KITCHEN ONLY.
06/10/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) SOIL WTR TEST IS OK FOR BLDG 'H' LEVEL P-1 WASTE AND VENT SYSTEM MENS AND WOMENS BALLROOM RESTROOMS BETWEEN GRID HH.1 TO II.2 AND BETWEEN COLUMN 27 TO 31.1 NOTE: 10' HEAD ON ALL VERTICAL VENTS ONLY.2) TUB WASTE AND OVERFLOW TEST IS OK FOR BLDG 'B' LEVEL 5 ALL REMANAINDER OF TUBS AS NOTED ON PLAN. 3) SOIL WTR TEST OK FOR WASTE AND VENT SYSTEM BLDG 'C' LEVEL 4 UP TO ROOF RM 6047, 6048 AS NOTED ON PLAN.
06/09/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) TUB WASTE AND OVERFLOWS WTR TEST OK FOR ALL TUBS ON BLDG 'A' LEVEL 4 AS NOTED ON PLAN. 2) TUB WASTE AND OVERFLOW WTR TEST IS OK FOR BLDG 'B' LEVEL 5 ROOMS 7028, 7030, 7031, 7032, 7033, 7035, 7037, 7038, 7040, 7039, AS NOTED ON PLAN. 3) OVERHEAD WTR DISTRIBUTION IS OK FOR HOT AND COLD LEVEL 5 BLDG 'B' AND LEVEL 4 BLDG A & B LESS TUB AND SHOWER VALVES AS NOTED. 4) WTR DISTRIBUTION HOT AND COLD SUPPLY IS STUBBED TO SHEER WALL AT END OF BLDG 'A' EAST ONLY. AIR PRESSURE TEST OK. 5) SOIL WTR TEST FOR 6" RWL IN BLDG H P-1 LEVEL 1 BETWEEN 11.2 AND GRID 31.1 AND 28 AS NOTED ON PLAN. 6) WASTE AND VENT FOR BLDG H LEVEL P-1 FOR TWO CARRIER RACKS FOR MENS AND WOMENS RESTROOMS AS NOTED ON PLAN. SOIL WTR TEST IS OK 10' UP VENT ONLY BETWEEN COLUMN HH1 TO II AND BETWEEN COLUMN #28 TO 31.1.
06/08/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
06/07/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) SOIL WTR TEST IS OK FOR BLDG 'C' LEVEL 2-5 AND TO ROOF IS OK AS NOTED ON PLAN. 2) TUB WASTE AND OVERFLOW TEST IS OK BLDG A, B, C, LEVEL 3 AS NOTED ON PLAN
06/03/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) soil wtr test is ok for bldg h. level p-1 vertical 6" waste for h east hotel between grid 32.1 and 30 on dd line only as noted on plan. 2) 6" rwl for bldg 'h' level p-1 on grid 25 line to column2 as noted on plan. 3) tub waste and overflow test is ok for bldg 'a' level 3 rm. 5008, 5012, 5014, 5016, 5018, 5020 as noted on plan.
06/02/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) TUB WASTE AND OVERFLOW TEST OK FOR BLDG 'B' LEVEL 3 ROOMS 5027, 5029, 5031, 5033, 5035, 5037, 5026, 5028, 5030, 5032, 5034, 5036, 5038, 5040. 2) TUB WASTE AND OVERFLOW TEST OK FOR BLDG 'C' LEVEL 3 ROOMS 5051, 5050, 5049, 5044, 5041 ONLY. 3) SOIL WTR TEST IS OK FOR BLDG 'C' LEVEL 2-5 TO ROOF ROOMS 4041, 4043, 4045, 4047, 5041, 5043, 5045, 5047, 6041, 6043. 4) 6" RWL FROM LEVEL 2-5 AND ROOF BLDG 'C' WTR TEST OK AS NOTED ON PLAN.
05/27/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) TUB WASTE AND OVERFLOW TEST IS OK FOR BLDG 'C' LEVEL 3 ROOMS 5049, 5050, 5047, 5048, 5045, 5043 AS NOTED ON PLAN. 2) SOIL WTR TEST IS OK FOR R.W.C. BLDG 'H' LEVEL P-1 AS NOTED ON PLAN. 3) SOIL WTR TEST IS OK FOR BLDG 'C' LEVEL 2-4 AND ROOF IS OK ROOM # 4049, 4051, 5049, 5051, 6045, AS NOTED ON PLAN.
05/26/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
05/25/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) SOIL WTR TEST IS OK FOR RAIN LEADERS AND PLANTER DRAIN IN BLDG 'H' BETWEEN GRIDS FF AND HH.1 AND GRID LINE 28 AND 29.2) SOIL WTR TEST IS OK FOR BLDG 'H' FOR RAIN WTR LEADER BETWEEN GRIDS HH.1 AND II.1 AND BETWEEN 28 AND 27.1. 3) 6" RAIN WTR LEADER WTR TEST IS OK AS NOTED ON PLAN.4) SOIL WTR TEST IS OK FOR SPECIALTY RESTAURANT BLDG 'H' LEVEL P-1 AS NOTED ON PLAN.
05/24/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) SOIL WTR TEST IS OK FOR BLDG C LEVEL 2&3 TO TOP OF ROOF ROOM 4053, 4054, 5049, 5050, AS NOTED ON PLAN. 2) SOIL WTR TEST IS OK FOR BLDG 'B' LEVEL 3-5 ROOM 5057, 5059, 6037, 6039, 7037, 7039, AS NOTED ON PLAN.
05/19/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ TUB WASTE AND OVERFLOW WTR TEST IS COMPLETE FOR BLDGS A-C LEVEL 2.
05/18/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
05/14/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) TUB WASTE AND OVERFLOW TEST IS OK FOR BLDG 'A' LEVEL 2 ROOM 4005, 4006, 4014, 4016 AS NOTED ON PLAN. 2) TUB WASTE AND OVERFLOW WTR TEST IS OK FOR BLDG 'B' LEVEL 2 ROOM 4022, 4024, 4026, 4028, 4030, 4032, 4034, 4036 AS NOTED ON PLAN.
05/13/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
05/13/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) WILL REQUIRE AN APPROVED DRAWING ON WASTE AND VENT SYSTEM FOR RESTAURANT BLDG 14 PRIOR TO INSP. DO NOT COVER. 2) TUB WASTE AND OVERFLOW TEST IS OK FOR BLDG 'A' LEVEL 2 ROOM 4007, 4009 4013, 4015, 4017, 4019, 4010. 3) SOIL WTR TEST IS OK FOR BLDG 'C' LEVEL 2-4, ROOM 4046, 4048, 4050, 4052, 5046, 5048, 5050, 5052, 6042, 6044, 6046.
05/11/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) SOIL WTR TEST IS OK FOR BLDG 'B' LEVEL 3-5, UNITS 5033, 5035, 5038, 5040, 6033, 6035, 6038, 6040, 7033, 7035, 7038, 7040, AS NOTED ON PLAN. 2) SOIL WTR TEST OK FOR VENDING AREA BLDG 'B', LEVEL 4-6 AS NOTED ON PLAN. 3) SOIL WTR TEST OR RAIN LEADER ON SOUTH BLDG 'B' FROM LEVEL 3-5 TO TOP OF ROOF.
05/10/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :
See detailed listing on site.| 999*/ 1) SOIL WATER TEST FOR TUBS WASTE AND OVERFLOWS FOR BLDG C LEVEL 1 ROOM # 3043, 3044, 3046, 3049 AND 3050 AS NOTED ON PLAN 2) SOIL WATER TEST IS OK FOR BLDG B LEVEL 3, 45 ROOM # 5029, 5031, 6029, 6031, 7079 AND 7031 3) GAS PRESSURE TEST IS OK FOR 1 1/4" SUPPLY AND ANZUL VALVE LOOP IN POOL BAR LEVEL P-2 BLDG C AS NOTED ON PLAN 4) SOIL WATER TERST IS OK FOR BLDG H LEVEL P-1 SPECIALTY RESTUARANT AS NOTED ON PLAN 5) NOTE: A REVISED AND APPROVED DRAWING ON WASTE OF VENT SYSTEM IN SPECIALTY RESTAURANT PRIOR TO FINAL INSPECTION
05/05/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ SOIL WTR TEST IS OK FOR 2" WASTE AND VENT FOR VENDING AREA BLDG B AND C CORNER LEVEL 2, 3 AND 4 AS NOTED ON PLAN.
05/04/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
04/27/2004 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) OVERHEAD VENT FOR KITCHEN AREA BLDG C LEVEL P-1 CALLS FOR 3" HORIZONTAL VENT SEE ICO 2-P5.02 ON WEST SIDE 2) SEE NOTE #5 ON INSPECTION 4/16/04
04/26/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) SOIL WATER TEST IS OK FOR WASTE AND VENT SYSTEM FOR BLDG B LEVEL 3, 4, 5 ROOMS # 5034, 5036, 6034, 6036, 7034, 7036, 7025, 7027, 6025 AND 6027 AS NOTED ON PLAN 2) GAS PRESSURE TEST OK FOR OVERHEAD AND IN WALL GAS DISTRIBUTION FOR BLDG C LEVEL P-1 IS OK AS NOTED ON PLAN
04/22/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 03005 - 4" BLD DRAIN FROM GG TO END OF LINE 4" C.O. FOR 2" FLOOR SINKS AND 2" FLOOR DRAINS WASTE AND VENT TO 2' ABOVE FINISHED FLOOR WTR TEST CENTERLINE 31 - CENTERLINE 32 OK. (SANITARY ONLY) 10 TOTAL WITH INITIAL P2.21 BB. / 03035 - 2" FLOOR SINK WASTE AND VENT WTR TEST FROM LEVEL P2 FOR V101 INCLUDING 2" DRAIN STUBBED NORTH EAST APPROX 20' FOR ADDED LAUNDRY SHOOT LEVEL P1 2" FLOOR SINK WASTE AND VENT V201 WTR TEST UP TO LEVEL 1 - V301 10' ABOVE FINISHED FLOOR OK. / 03050 - 60 PSI MIN. TEST AT TIME OF INSP. PROVIDE APPROVED BLK I.P. CAPS.
04/20/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) SOIL WTR TEST IS OK FOR WASTE AND VENT SYSTEM BLDG 'B' LEVEL 4 & 5, ROOMS 6030, 6032, 7030, 7032, AS NOTED ON PLAN. 2) TUB WASTE AND OVERFLOWS TEST IS OK FOR BLDG 'C', LEVEL 1, ROOMS 3053, 3056, 3051, 3050, 3049, 3048, 3047, 3045, 3043, 3042 AS NOTED ON PLAN.
04/16/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) MUST PROVIDE AIR TEST GUAGE WITH 60 LBS. ON WELDED PIPE. 2) TUB WASTE AND OVERFLOW IS OK FOR BLDG 'A' LEVEL 1 AS NOTED ON PLAN - ROOMS 3005, 3007, 3009, 3011, 3013, 3015, 3017, 3019, 3010, 3012, 3014, 3016, 3018, 3020, 3022, 3023, 3024, 3025. 3) H AND C DROPS IN WALL ARE OK FOR BLDG 'C' LEVEL P-1 AIR PRESSURE TEST IS OK. 4) H & C WTR SUPPLY FOR BLDG A-C LEVEL 3 IS OK. AIR PRESSURE TEST ON SYSTEM IS OK. 5) HOT SYSTEM ON LEVEL 2, A-C HAVE BEEN INSULATED PRIOR TO INSPECTION. MUST REMOVE INSULATION AS REQUESTED.
04/14/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) TUB WASTE AND OVERFLOW WATER TEST IS OK FOR BLDG 'B', LEVEL 1 ROOMS 3021, 3022, 3026, 3027, 3028, 3030, 3032, 3034, 3036, 3038, 3040 AS NOTED ON PLAN. 2) RAIN WTR LEADER WTR TEST IS OK BLDG 'B', LEVELS 2-5 SOUTH SIDE AS NOTED ON PLAN. 3) SOIL WTR TEST IS OK FOR WASTE AND VENT SYSTEM BLDG 'B', LEVELS 3-5, ROOMS 7022, 7024, 7026, 7028, 6022, 6024, 6026, 6028, 5022, 5024, 5026, 5028 AS NOTED ON PLAN.
04/12/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) SOIL WTR TEST IS OK FOR 6" RAIN LEADER IN BLDG. H LEVEL P-1 BETWEEN COLUMN 31-1 TO 34 AND GG1 TO II-1 AS NOTED ON PLAN. 2) SOIL WTR TEST IS OK FOR FLOOR SINK BLDG 'D' LEVEL P-1. 3) SOIL WTR TEST FOR 6" RAIN LEADER FOR BLDG 'B' LEVEL 2-5, NORTH SIDE BETWWEN GRID 15.1 AND G &H AND I&J AS NOTED ON PLAN. 4) SOIL WTR TEST IS OK FOR WASTE AND VENT BLDG 'B' LEVEL 3-5, UNITS 7021, 7023, 6021, 2023, 5021, 5023, 5025, 5027, AS NOTED ON PLAN.
04/06/2004 PLUMBING - INTERMEDIATE Partial Approval 1) SOIL WTR TEST IS OK FOR RAIN LEADER IN BLDG 'A' - N.W. CORNER ALL FLOORS. 2) SOIL WTR TEST OK IN BLDG 'A' LEVEL 3&4 ROMMS 4014, 4016, 4018, 4020, 5006, 5008, 5012, 5014, 5016, 5018, 5020, 6014, 6016, 6018, 6020.
04/01/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) SOIL WTR TEST IS OK FOR 6" RAIN LEADER BLDG 'B' SOUTH WEST LEADER ALL THE WAY TO ROOF. 2) SOIL WTR TEST IS OK FOR BLDG 'A' LEVEL P-1, 1-4, ROOMS 2008, 3005, 4003, 5005 AS NOTED ON PLAN.
03/31/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) SOIL WTR TEST IS OK FOR BLDG 'A' LEVELS 1-3, ROOMS 3005, 3010, 3012, 3014, 3016, 3018, 3020, 4003, 4010, 4012, 4014, 4016, 4018, 4020, 5005, 5008, 5012, 5014, 5016, 5018, 5020 AS NOTED ON PLAN. 2) SOIL WTR TEST IS OK FOR 6" RAIN LEADER BLDG A&B
03/29/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*
03/25/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ SOIL WTR TEST IS OK FOR BLDG 'A' LEVEL 4 FOR RMS 6013, 6015, 6017, 6019.
03/24/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ WTR TEST FOR TUBS WASTE AND OVERFLOW AND TRAP IS OK FOR BLDG B LEVEL P-1, ROOMS 2022, 2024, 2026, 2028, 2030, 2032, 2034, 2036, 2038, 2040 ONLY AS NOTED ON PLAN IN PURPLE
03/23/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/OVERHEAD WTR DISTRIBUTION IS OK FOR BLDG 'C' LEVEL 1 & 2 - ROOMS 3041-3056 AND 4043-4054.
03/22/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) SOIL WATER TEST IS OK FOR BLDG "B". LEVEL 1 AND 2 ROOMS #3021, 3023, 3025, 3027, 3035, 3040, 4021, 4023, 4025, 4027, 4038 AND 4040
03/19/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) SOIL WATER TEST IS OK FOR WASTE AND VENT SYSTEM FOR BLDG B LEVEL 1 AND 2 ROOMS #3030, 3034, 3036, 4029, 4030, 4031, 4032, 4033, 4034, 4035 AND 4036 AS NOTED ON PLAN
03/17/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/1) OVERHEAD WTR DISTRIBUTION IS OK FOR BLDG 'B' LEVEL 1, HOT AND COLD AIR PRESSURE TEST 100 LBS IS OK AS NOTED ON PLAN. 2) SOIL WTR TEST IS OK FOR BLDG 'B' LEVEL 1 & 2, ROOMS 3007 AND 4005 AND BLDG 'A', LEVEL 1 & 2 ROOMS 3010, 3012, 4010, 4012 ARE OK.
03/15/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) OVERHEAD WTR DISTRIBUTION AND AIR TEST IS OK FOR UNITS 1022, 1024, 1026, 1028, 1030, 1032, 1034, 1036, 1038, 1040, BLDG 'B' LEVEL P-2 ARE OK AS NOTED ON PLAN. 2) OVERHEAD WTR DISTRIBUTION AND AIR TEST IS OK FOR BLDG 'B' LEVEL P-1 ROOMS 2022, 2024, 2026, 2028, 2030, 2032, 2034, 2036, 2038, 2040, ARE OK AS NOTED ON PLAN. 3) OVERHEAD WTR DISTRIBUTION AND AIR TEST FOR BLDG 'A' LEVEL P-1 ROOMS 2008, 2010, 2012, 2014, 2016, 2018, 2020, ARE OK AS NOTED ON PLAN. 4) OVERHEAD WTR DISTRIBUTION AND AIR TEST FOR BLDG 'A' LEVEL 1 ROOMS 3008, 3010, 3012, 3014, 3016, 3018, 3020, AS NOTED ON PLAN. 5) OVERHEAD WTR DISTRIBUTION AND AIR TEST FOR BLDG 'A' LEVEL 1 ROOMS 3005, 3007, 3009, 3011, 3013, 3015, 3017, 3019, AND RMS 3021, 3023, 3025, 3027, ARE OK AS NOTED ON PLAN. 6) SOIL WTR TEST IS OK FOR BLDG'B' LEVEL 1&2 RMS 3026, 3028, 4026, 4028.
03/12/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) SOIL WTR TEST IS OK FOR BLDG 'A' LEVEL 2 RM 4006. 2) SOIL WTR TEST IS OK FOR BLDG 'A' LEVEL 1 RM 3008
03/11/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ SOIL WATER TEST FOR SANITARY WASTE AND VENT SYSTEM IS OK FOR BLDG 'A' LEVEL 1 RM 3009, 3011, AND LEVEL 2 BLDG 'A' RMS 4007, 4009, 4013, 4015, 4017, 4019 ONLY.
03/09/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) SOIL WTR TEST IS OK FOR BLDG A 6" RWL WEST END AS NOTED ON PLAN. 2) OVERHEAD WTR DISTRIBUTION IS OK FOR UNITS 2018 AND 2020, HOT AND COLD , AND 3018 AND 3020 AS WELL - BLDG 'A' LEVEL P-1. 3) RM 2008, 2010, 2012, 2014, 2016, HOT ONLY - BLDG 'A' LEVEL P-1. 4) RM 3008, 3010, 3012, 3014, 3016, HOT ONLY BLDG 'A' LEVEL 1. 5) RM 3017, 3019, HOT AND COLD BLDG 'A' LEVEL 1. RM 3005, 3007, 3009, 3011, 3013, 3015, HOT ONLY BLDG 'A' LEVEL 1.
03/08/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ SOIL WATER TEST FOR 6" RAIN LEADER BETWEEN GRID LINE D & E AND #15 LINE IS OK. BLDG A LEVEL 1 P-1.
03/04/2004 PLUMBING - INTERMEDIATE Not ready for Inspection NOT READY DUE TO RAIN
03/03/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ SOIL WTR TEST IS OK FOR BLDG 'A' LEVEL P-1 AS NOTED ON PLAN.
03/02/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) SOIL WATER TEST IS OK. 2) THIS INSPECTION IS FOR 6" RWL BLDG B P-1 LEVEL AND LEVEL 1 VERTICAL:HORIZONTAL ON COLUMN G15.1. 3) SANITARY WASTE FOR BLDG A P-1 LEVEL 1 ROOM 2014, 2016.
02/27/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) OVERHEAD WATER DISTRIBUTION IS OK FOR ALL UNITS BLDG C LVEL P-2 AS NOTED ON PLAN 2) 6" RWL WATER TEST OK BLDG C LEVEL P-2 AS NOTED ON PLAN
02/25/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) SOIL WATER TEST IS OK FOR ROUGH PLUMBING. UNITS #1022, 1024, 1026 AND 1028 2) 6" WASTE FOR LEVEL P-1 IS OK AS NOTED ON PLAN 3) 6" RWL TEST FROM LEVEL P-2 TO P-1
02/23/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) 2" OVERHEAD GAS LINE FROM UNIT 1053 TO STUBB OUT INTO POOL GRILL KITCHEN IS OK. AIR TEST IS OK. 2) 6" RWL BLDG 'B' LEVEL 1 & 2 IS OK AS NOTED ON PLAN.
02/19/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) OVERHEAD WTR AIR TEST IS OK. 2) THIS INSPECTION IS FOR CASUAL KITCHEN, BLDG C LEVEL P-1 AS NOTED ON PLAN. 3) OVERHEAD WTR IN POOL BAR BLDG C LEVEL P-2 AS NOTED ON PLAN.
02/13/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) SOIL WTR TEST IS OK. 2) THIS INSPECTION IS FOR BLDG 'B' , UNITS 1030, 1032, 1034, 1036, 1038, 1040 ONLY LEVEL P-2.
02/12/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*
01/23/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) SOIL WTR TEST IS OK FOR BLDG 'C' LEVEL P-2 ROOM 1056 IS OK. 2) SOIL WTR TEST FOR RAIN LEADERS IN BLDG 'S' BETWEEN COLUMN UU.1 TO XX AND BETWEEN COLUMN 28 AND 27.4 IS OK.
01/21/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*
01/20/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) SOIL WATER TEST IS OK FOR RAIN LEADERS IN BLDG. I, BETWEEN GRID NN AND QQ1 AND BETWEEN 33 AND 34. 2) SOIL WATER TEST IS OK FOR RAIN LEADERS IN BLDG J BETWEEN COLUMN VV TO ZZ AND 31-1 TO 32-1 AS NOTED ON PLAN.
01/12/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) WTR TEST FOR VENT SYSTEM IN BLDG C LEVEL P-2 BETWEEN GRID 18 - 21 AND BETWEEN K-1 TO O-1 IS OK. 2) WATER TEST FOR BLDG C P-2 LEVEL POOL KITCHEN AREA VENT SYSTEM IS OK AS NOTED ON PLAN. 3) BAR STORAGE OVERHEAD VENTING IS OK AS NOTED ON PLAN.
01/08/2004 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*/ 1) 4" HORIZONTAL WASTE LINE EXCEEDS 135 DEGREE CHANGE OF DIRECTION 2) HORIZONTAL VENTING BELOW THE FLOOD RIM LEVEL REQUIRES L-SWEEPS FROM VERTICAL TO HORIZONTAL 3) RETEST SYSTEM
01/07/2004 PLUMBING - INTERMEDIATE Denied 1) CANNOT CONNECT OVERFLOW ROOF DRAINS TO PRIMARY ROOF DRAINS. SEE SECTION APPENDIX D1.1 SUB NOTE C