Permit: T03CM02796

Parcel: 11628001E

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/13/2005 FRAMING Approved IVRS - Inspection :*
01/11/2005 FRAMING Partial Approval IVRS - Inspection :*
01/07/2005 FRAMING Partial Approval IVRS - Inspection :*
01/06/2005 FRAMING Partial Approval IVRS - Inspection :*
01/05/2005 FRAMING Partial Approval IVRS - Inspection :*
01/04/2005 FRAMING Partial Approval IVRS - Inspection :*
01/03/2005 FRAMING Partial Approval IVRS - Inspection :*/1)FRAMING FOR SHAFT WALLS STAIR 21 OK
12/30/2004 FRAMING Partial Approval IVRS - Inspection :*
12/29/2004 FRAMING Partial Approval IVRS - Inspection :*
12/28/2004 FRAMING Partial Approval IVRS - Inspection :*
12/27/2004 FRAMING Partial Approval IVRS - Inspection :*
12/23/2004 FRAMING Partial Approval IVRS - Inspection :*
12/22/2004 FRAMING Partial Approval IVRS - Inspection :*
12/21/2004 FRAMING Partial Approval IVRS - Inspection :*
12/20/2004 FRAMING Partial Approval IVRS - Inspection :*
12/17/2004 FRAMING Partial Approval IVRS - Inspection :*/1)POOL HOUSE OK TO COVER 2)C=P2 ROOM 1338 WAS OK
12/16/2004 FRAMING Partial Approval IVRS - Inspection :*
1) POOL HOUSE ROOF FRAMING WILL REQUIRE GFI ON RIDGE BLOCK NAILING FROM ?
12/15/2004 FRAMING Partial Approval IVRS - Inspection :*/1)STAIRS & RAMP OFF SOUTH SIDE OF OUTDOOR BALLROOM OK 2)SITE WALL FOOTING SW CORNER AT G OK 3)P2-G STOREROOM WALLS ARE RATED BARRIERS YOU NEED FIRE STOP AND FIRE DAMPERS 4)PENTHOUSES D-G OK. AREA A-E ARE LACKING (1) HORIZ. FIRE BARRIERS P2-P1/D 2)ROOM 1336 P-2C 1HR. BARRIER TO CORRIDOR 3)FINALS IN RESTAURANT 4)FLOOR OPENINGS IN ELECTRIC ROOMS OVERSIZED FOR FIRE DAMPERS. REVIEW RUSKIN DETAIL FOR HILTR? FS-ONE FIRESTOP. IT MIGHT WORK
12/14/2004 FRAMING Partial Approval IVRS - Inspection :*
12/13/2004 FRAMING Partial Approval IVRS - Inspection :*
12/10/2004 FRAMING Partial Approval IVRS - Inspection :*
12/09/2004 FRAMING Partial Approval IVRS - Inspection :*
1) LEVELS P1 & 1, G & 4 KNUCKLE OK TO ROCK SOFFITS AND LIDS
12/08/2004 FRAMING Partial Approval IVRS - Inspection :*
1) 3-G KNUCKLE OK
2) WINGS D AND E GUST SUITES OK TCO FOR MARRIOT STAFF
NOTE: SAME RULES 1/4 CONDITIONS AS OTHER AREAS EG KEEP EGRESS DOOR AND CLEAR; DO NOT BLOCK OPEN FIRE DOORS
3) I STILL NEED TO SEE COMPLETED SHAFTS IN PENT HOUSES
12/07/2004 FRAMING Partial Approval IVRS - Inspection :*
12/03/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
12/02/2004 FRAMING Partial Approval IVRS - Inspection :*
12/01/2004 FRAMING Partial Approval IVRS - Inspection :*
11/30/2004 FRAMING Partial Approval IVRS - Inspection :*
11/29/2004 FRAMING Partial Approval IVRS - Inspection :*
11/26/2004 FRAMING Partial Approval IVRS - Inspection :*
11/24/2004 FRAMING Partial Approval IVRS - Inspection :*
11/22/2004 FRAMING Partial Approval IVRS - Inspection :I-H READY TO ROCK
I-F 2 HOUR FLOOR SEPERATION OK
INSTALL FIRESTOP IN WALL VOIDS AND EXPANSION JOINT AND RECALL
G-PL MECHANICAL ROOMS
FINISH FIRE STOP @ SPRINKLER PIPE M206
FINISH FIRE STOP @ ELEC CONDUITS M205
MAKE C.E.S. WALL RETURN BY DOOR IN M205 INTO A 1 HOUR SEPERATION WALL LARGE MECH DUCT INSTALLED IN ROOM HAS ALTERED ORIGINAL DESIGN.
11/18/2004 FRAMING Partial Approval IVRS - Inspection :I-H FRAMING WALLS, SOFFITS, HARD LIDS ETC OK , OK TO COVER
11/17/2004 FRAMING Partial Approval IVRS - Inspection :*
11/16/2004 FRAMING Partial Approval IVRS - Inspection :*
11/15/2004 FRAMING Partial Approval IVRS - Inspection :*
11/12/2004 FRAMING Partial Approval IVRS - Inspection :*
11/10/2004 FRAMING Partial Approval IVRS - Inspection :*
11/09/2004 FRAMING Partial Approval IVRS - Inspection :*
11/08/2004 FRAMING Partial Approval IVRS - Inspection :*
11/05/2004 FRAMING Partial Approval IVRS - Inspection :*
11/03/2004 FRAMING Partial Approval IVRS - Inspection :*
11/02/2004 FRAMING Partial Approval IVRS - Inspection :*
11/01/2004 FRAMING Partial Approval IVRS - Inspection :*
10/27/2004 FRAMING Partial Approval IVRS - Inspection :*
10/26/2004 FRAMING Partial Approval IVRS - Inspection :*
10/25/2004 FRAMING Partial Approval IVRS - Inspection :*
10/22/2004 FRAMING Partial Approval IVRS - Inspection :*
10/21/2004 FRAMING Partial Approval IVRS - Inspection :*
10/20/2004 FRAMING Partial Approval IVRS - Inspection :*
10/19/2004 FRAMING Partial Approval IVRS - Inspection :*
10/15/2004 FRAMING Partial Approval IVRS - Inspection :*
10/14/2004 FRAMING Partial Approval IVRS - Inspection :*
10/13/2004 FRAMING Partial Approval IVRS - Inspection :*
10/12/2004 FRAMING Partial Approval IVRS - Inspection :*
10/11/2004 FRAMING Partial Approval IVRS - Inspection :*
10/08/2004 FRAMING Partial Approval IVRS - Inspection :*
10/06/2004 FRAMING Partial Approval IVRS - Inspection :*
10/05/2004 FRAMING Partial Approval IVRS - Inspection :*
10/01/2004 FRAMING Partial Approval IVRS - Inspection :*PARTIAL APPROVAL. 1) F-1 SOFFITS OK, REPAIR MANOKOTE(?) BEFORE COVERING. 2) I-1 ABOVE CEILING OK (EASTSIDE OF BUS TURNAROUND). 3) D-EAST ABOVE CEILING OK- OK TO COVER WHEN ELECTRIC APPROVED.
09/30/2004 FRAMING Partial Approval IVRS - Inspection :*
09/28/2004 FRAMING Partial Approval IVRS - Inspection :*
09/27/2004 FRAMING Partial Approval IVRS - Inspection :*
09/23/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) OK TO START ROCKING KITCHEN AND PUBLIC AREAS C, D AREAS
09/22/2004 FRAMING Partial Approval IVRS - Inspection :*
09/15/2004 FRAMING Partial Approval IVRS - Inspection :*/ CF8 PROGRESS AREAS G AND H OK
09/14/2004 FRAMING Partial Approval IVRS - Inspection :*
09/13/2004 FRAMING Partial Approval IVRS - Inspection :*
09/10/2004 FRAMING Partial Approval IVRS - Inspection :*
09/09/2004 FRAMING Partial Approval IVRS - Inspection :*
09/08/2004 FRAMING Partial Approval IVRS - Inspection :*
09/02/2004 FRAMING Partial Approval IVRS - Inspection :*
09/01/2004 FRAMING Partial Approval IVRS - Inspection :*
08/31/2004 FRAMING Partial Approval IVRS - Inspection :*
08/30/2004 FRAMING Partial Approval IVRS - Inspection :*
08/26/2004 FRAMING Partial Approval IVRS - Inspection :*
08/25/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) 6-D COMPLETE
08/24/2004 FRAMING Partial Approval IVRS - Inspection :*
08/18/2004 FRAMING Partial Approval IVRS - Inspection :*
08/16/2004 FRAMING Partial Approval IVRS - Inspection :*
08/13/2004 FRAMING Partial Approval IVRS - Inspection :*
08/12/2004 FRAMING Partial Approval IVRS - Inspection :*
08/10/2004 FRAMING Partial Approval IVRS - Inspection :*
08/09/2004 FRAMING Partial Approval IVRS - Inspection :*
08/06/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) AREA G READY TO SKIN 2) AREA H NORTH SIDE READY TO SKIN
08/05/2004 FRAMING Partial Approval IVRS - Inspection :*
08/04/2004 FRAMING Partial Approval IVRS - Inspection :*
08/02/2004 FRAMING Partial Approval IVRS - Inspection :*
07/28/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) PRE-FUNCTION AREAS I, J OK TO ROCK
07/27/2004 FRAMING Partial Approval IVRS - Inspection :*
07/26/2004 FRAMING Partial Approval IVRS - Inspection :*
07/22/2004 FRAMING Partial Approval IVRS - Inspection :P1-C C.F.S. PROGRESS OK SOFFITS, HARD LIDS, ETC.
07/21/2004 FRAMING Partial Approval IVRS - Inspection :PLEASE PROVIDE RFI FOR BEAMBEARING ( COLUMN SUPPORTS) @ PENTHOUSES RIGHT NOW EVERYTHING HANGS ON FLANGES & CFI SUPPORTS
07/20/2004 FRAMING Partial Approval IVRS - Inspection :*
07/14/2004 FRAMING Partial Approval IVRS - Inspection :*G-J GENERAL SITE REVIEW CFS PROGRESS OK IN GENERAL I NEED TO SEE REPAIRS TO FIRE PROOFING (MONOKOTE) BEFORE COVERING CFS. THIS IS MOSTLY ALONG BALCONIES AT I & J WHERE MONOKOTE WAS REMOVES FOR CFS.
07/13/2004 FRAMING Partial Approval IVRS - Inspection :*
07/09/2004 FRAMING Partial Approval IVRS - Inspection :*AREA E PROGRESS WITH CFS FRAME OK.
07/07/2004 FRAMING Partial Approval IVRS - Inspection :*
07/02/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) P1-C HARD LIDS IN SOUTH KITCHEN AREA 2) OK TO COVER
06/30/2004 FRAMING Partial Approval IVRS - Inspection :*
06/29/2004 FRAMING Partial Approval IVRS - Inspection :*
06/14/2004 FRAMING Partial Approval IVRS - Inspection :*
06/09/2004 FRAMING Partial Approval IVRS - Inspection :*
06/08/2004 FRAMING Partial Approval IVRS - Inspection :*
06/07/2004 FRAMING Partial Approval IVRS - Inspection :* 1) AREA D WEST SIDE CFS SKELETON LEVELS 2-5 OK. 2) AREA E CFS SKELETON OK EAST & WEST SIDE OK.
06/04/2004 FRAMING Partial Approval IVRS - Inspection :*
06/02/2004 FRAMING Partial Approval IVRS - Inspection :* POP OUTS @ 24-J OK
05/28/2004 FRAMING Partial Approval IVRS - Inspection :*
05/27/2004 FRAMING Partial Approval IVRS - Inspection :*
05/20/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) 2-A,B,C A) INTERIOR FRAME OK 2) PROGRESS ON EXTERIOR FRAME AREAS D, E OK
05/18/2004 FRAMING Partial Approval IVRS - Inspection :*
05/17/2004 FRAMING Partial Approval IVRS - Inspection :*
05/03/2004 FRAMING Partial Approval IVRS - Inspection :*
04/20/2004 FRAMING Partial Approval IVRS - Inspection 0000* 1) P1-E FRAMING OK. 2) 1 A-E FRAMING PROGRESS OK.
04/16/2004 FRAMING Partial Approval IVRS - Inspection 0000*
04/15/2004 FRAMING Partial Approval IVRS - Inspection 0000* 1) CFS SKIN N SIDE OF A OK. 2) INTERIOR FRAMING (CFS) WINGS ABC OK. 3) progress on framing in i, j good ready to close (cover) most areas.
04/05/2004 FRAMING Partial Approval IVRS - Inspection 0000* 1) AREA A, B, C PROGRESS ON CFS SKINS OK. 2) WING C EAST SIDE PROGRESS ON STUCCO MESH OK. 3) P1-C I NEED TO SEE ELEC, PLBG & MECH INSP REPORTS FOR THIS AREA.
03/29/2004 FRAMING Partial Approval IVRS - Inspection 0000* GUEST SUITES P2-C OK. P2-B OK TO ROCK
03/24/2004 FRAMING Partial Approval IVRS - Inspection 0000* NEED ALL TRADES PRIOR TO FRAMING FINAL
03/23/2004 FRAMING Partial Approval IVRS - Inspection 0000* PROGRESS AREA I, J FOR C.F.S. IS OK 2) P2-B, C GENERALLY OK, SOME BACKING REQUIRED.
03/17/2004 FRAMING Partial Approval IVRS - Inspection 0000* AREWA B, C OK TO SKIN SOUTH B & SOUTH & WEST C
03/09/2004 FRAMING Partial Approval IVRS - Inspection 0000* 1) WING C OK TO SKIN EAST FACE. 2) REMEMBER BACK TO BACK OUTLETS IN RATED WALLS REQUIRE 1 TO HAVE A PUTTY PAD.
02/24/2004 FRAMING Partial Approval IVRS - Inspection 0000*
02/11/2004 FRAMING Partial Approval IVRS - Inspection 0000* P2-C MOCK UP FRAMING OK