Inspection History Details
Inspection Status: Approved
Inspection History: ENGINEERING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/13/2004 | ENGINEERING - FINAL | Approved | ||
| 05/07/2004 | ENGINEERING - FINAL | Denied | 1. SUBMIT THE REVISED SITE PLAN TO THE CITY OF TUCSON ENGINEERING AND ZONING DIVISIONS FOR APROVAL. 2. PROVIDE ALL STRIPING AS SHOWN OF THE PLAN, LOADING ZONE 35' LENGTH, TWO WAY TRAFFIC ARROWS, AND THE PEDESTRIAN WALKWAY AT THE ENTRANCE. 3. PROVIDE HANDICAP PARKING SIGNS AND ALL WHEEL STOPS. 4. PAVING MUST COME FLUSH TO SIDEWALK AT EAST END OF HANDICAP PARKING. 5. PROVIDE 24' PAAL AND MOVE NORTH PARKING SPACES CLOSE TO NORTH FENCE. 6. PROVIDE EXTRUDED CURB WHERE DESIGNATED. |
|
| 03/19/2004 | ENGINEERING - FINAL | Denied | 1. PROVIDE COMPLETE STRIPING OF ALL PARKING SPACES, PEDESTRIAN WALKWAYS, LOADING ZONE AND HANDICAP PARKING SPACES. PROVIDE MINIMUM 9' X 18' PARKING SPACES. 2. PROVIDE 24' WIDE ENTRANCE AND EXTRUDED CURB FOR DRIVEWAY AND PARKING AREAS. 3. PROVIDE "T" SHAPED TURNAROUND FOR FIRE TRUCKS AND LOADING VEHICLES. 4. PROVIDE 6' CHAINLINK FENCE WITH SLATS AT FRONTAGE ROAD. 5. PROVIDE (2) BICYCLE PARKING SPACES. 6. PROVIDE CONCRETE WHEEL STOPS AT ALL PARKING SPACES. 7. PROVIDE FOR ROOF DRAINAGE TO PAVEMENT ON SOUTH SIDE OF NEW BUILDING. 8. CLEAN UP AND REMOVE ALL CONSTRUCTION MATERIAL AND DEBRIS. 9. CONSTRUCT ALL SITE WORK TO APPROVED SITE PLAN OR SUBMIT A REVISED PLAN TO C.O.T. ENGINEERING AND ZONING DIVISIONS FOR APPROVAL. |