Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T03CM02533
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/06/2003 | EXCAVATION/LAYOUT REBAR & ZON | Approved | ||
08/26/2003 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection 0000* | |
08/20/2003 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection 0999* 1)PLAN CALLS FOR 16FT BETWEEN UINITS-ONLY 6FT EXISTS. HAVE PLAN REVISED TO AS BUILT AND APPROVED BY CITY. 2)PLAN CALLS FOR 2X6 FLOOR JOIST. 2X4 USED. BUILD TO PLAN 3)UNTREATED WOOD WITHIN 6" OF SOIL NOT ALLOWED 4)FOUNDATION NOT ? PER PLAN 5)EXTERIOR CLIP MUST EXTEND TO FOUNDATION 6)HEADERS MUST BEAR ON TRIMMERS 7)HEADER REQUIRED FOR A/C 8)DOUBLE TOP PLATE SPLICES NOT ALLOWED WITHIN ? OF ANOTHER SPLICE 9)ALL SPLICES MUST OCCURE OVER STUDS 10)SOUTH WALL MUST BE CLIPPED TOP & BOTTOM |
|
07/21/2003 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection 0000*/ 1) CANCELLED BY OFFICE |